EVEREADY BATTERY CO.
+ 44 (0) 208 920 2306 / EUROPE
ENERGIZER NO. EV190
Industry Standard Dimensions in mm (inches)
THIS BATTERY WILL PASS FREELY THROUGH A CYLINDRICAL TUBE 82.6 DIAMETER x 101.6 LONG.
| 6V |
| INDUSTRIAL HEAVY DUTY |
| NOT INTENDED FOR RETAIL TRADE |
Chemical System: | |
| (No Added Mercury or Cadmium) |
Designation: | |
Battery Voltage: | 6 Volts |
Operating Temp: | |
Average Weight: | 589 grams (20.8 oz.) |
Volume: | 480 cubic centimeters (29.2 cubic inch) |
Average Capacity: | 11 Ah to 0.8 volts / cell |
| (Rated at 25k ohms continuous at 21ºC) |
Cell: | Four No. 60 (size "F") in series |
Terminals: | Coil Spring |
Jacket: | Plastic |
INTERNAL RESISTANCE VS. TEMPERATURE
The measurement is an approximation of the battery's actual internal resistance. It is sensitive to the loads and operator technique.
Schedule: Background Load 600 ohms
Pulse Load 10 ohms
Pulse Duration 1 second
Temperature | Typical Ri (ohms) |
45ºC (113ºF) | 0.7 |
21ºC (70ºF) | 0.9 |
0ºC (32ºF) | 1.0 |
10.0 |
CONSTANT RESISTANCE PERFORMANCE | CONSTANT CURRENT DISCHARGE |
Typical Service | Typical Service |
| 1000 |
|
|
|
| 1000 |
|
|
|
|
|
|
|
|
|
|
|
| |
Service, Hours | 100 |
|
|
| Service Hours | 100 |
|
|
|
10 |
| 3.0 Cutoff Voltage |
| 10 | 3.0 Cutoff Voltage |
|
| ||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |
|
|
| 4.4 Cutoff Voltage |
|
|
| 4.4 Cutoff Voltage |
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 5.2 Cutoff Voltage |
|
|
| 5.2 Cutoff Voltage |
|
|
| 1 |
|
|
|
| 1 |
|
| |
|
|
|
|
|
|
|
| ||
| 1 | 10 | 100 | 1000 |
| 1 | 10 | 100 | 1000 |
Discharge Resistance, Ohms | Discharge Current, mA |