Dell MD1000 owner manual Troubleshooting Enclosure Cooling Problems

Page 47

Action

CAUTION: Only trained service technicians are authorized to remove the enclosure cover and access any of the components inside the enclosure. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the enclosure and protecting against electrostatic discharge.

NOTICE: It is recommended to power down the server before powering down the enclosure to prevent loss of communication.

1Check that at least two drives are present in the enclosure. A minimum of two drives must be installed. If they are not, install the minimum number of drives. If the problem persists, go to step 2.

2Locate the faulty power supply and determine the status of the LEDs.

If the AC Power LED is not lit, troubleshoot the power cord and power source into which the power supply is plugged.

Use a known good power source (outlet).

Use a known good power cord.

If the DC power LED is not lit, verify that the power switch is turned on. If the power switch is turned on, continue to step 3.

If the power supply's fault indicator is lit, continue to step 3.

NOTICE: Power supply/cooling fan modules are hot-pluggable. The enclosure can operate on a single functioning power supply; however, both modules must be installed to ensure proper cooling. A single power supply/cooling fan module can be removed from the enclosure for up to 5 minutes, provided the other module is functioning properly. After 5 minutes, the enclosure will overheat and may cause an automatic thermal shutdown.

3Ensure that the power supply is properly installed by removing and re-installing it. See "Removing and Installing the Power Supply/Cooling Fan Module."

NOTE: After installing a power supply, allow several seconds for the enclosure to recognize the power supply and to determine if it is working properly.

4If the problem persists, see "Getting Help."

Troubleshooting Enclosure Cooling Problems

Problem

Systems management software issues a fan-related error message.

Action

Ensure that none of the following conditions exist:

Ambient temperature is too high.

External airflow is obstructed.

A power supply/cooling fan module has failed. See "Troubleshooting a Fan."

Troubleshooting Your Enclosure

47

Image 47
Contents Dell PowerVault MD1000 Storage Enclosure May Contents Troubleshooting Your Enclosure Getting Help Contents Other Information You May Need About Your SystemIndicators on the Enclosure Bezel Front-Panel Components Icon Condition Front-Panel Indicators and FeaturesDrive Carrier LED Indicators Drive Carrier LED IndicatorsLED Back-Panel Indicators and FeaturesEnclosure Management Module EMM Back-Panel FeaturesEMM External Panel EMM Component Functions Icon Unified Mode and Split Mode About Your System Enclosure Mode Switch Settings Enclosure Failover When Two EMMs are InstalledEMM Thermal Shutdown Power Supply and Cooling Fan FeaturesCritical and Noncritical Events Critical Events Enclosure AlarmsBefore You Begin Cabling Your Enclosure for Unified or Split ModeOperating Your Storage Enclosure Connecting the Enclosure Unified Mode Split Mode Minimum Requirements Operating Your Storage Enclosure Changing Your Enclosure’s Operating Mode Downloading Firmware Managing Your Storage EnclosureOperating Your Storage Enclosure Removing and Replacing the Front Bezel Installing Enclosure ComponentsRecommended Tools Installing and Removing the Front Bezel Removing and Installing DrivesRemoving Drives from the Enclosure Installing and Removing DrivesInstalling SAS Drives in the Enclosure Installing the Drive in the Carrier Installing Sata Drives in the Enclosure Screws Removing an EMM Removing and Installing an EMMRemoving and Installing an EMM Installing an EMMInstalling and Removing an EMM Module Cover Installing an EMM Module Cover in an Empty BayRemoving and Installing the Power Supply/Cooling Fan Module Replacing the Power Supply Removing a Power Supply/Cooling Fan ModuleRemoving the Control Panel Removing and Installing the Control PanelInstalling a Power Supply/Cooling Fan Module Removing and Replacing the Control Panel Installing the Control PanelRemoving and Replacing the EMM/Power Supply Cage Removing and Installing the Midplane10. Removing and Installing the Midplane Installing Enclosure Components Start-Up Routine Troubleshooting Your EnclosureSafety First-For You and Your Enclosure Troubleshooting a Loss of Communication ConditionForeign Configuration Failed Virtual Disks Troubleshooting a Wet Enclosure Troubleshooting External ConnectionsTroubleshooting Power Supplies Troubleshooting a Damaged EnclosureTroubleshooting Enclosure Cooling Problems Troubleshooting a Fan Troubleshooting SAS and Sata DrivesTroubleshooting Enclosure Connections Troubleshooting Your Enclosure Technical Assistance Online ServicesGetting Help Technical Support Service AutoTech ServiceAutomated Order-Status Service Getting Help Contacting Dell Before You CallGlossary GlossaryDIN Deutsche Industrie Norm Glossary Glossary Glossary System memory See RAM Glossary Glossary Index Index
Related manuals
Manual 11 pages 28.32 Kb Manual 64 pages 33.5 Kb

MD1000 specifications

The Dell MD1000 is a storage enclosure designed to provide a scalable and reliable solution for enterprises seeking efficient data storage management. Recognized for its robust performance and versatility, the MD1000 supports a variety of applications, making it a popular choice among organizations that demand high-capacity storage solutions.

One of the standout features of the MD1000 is its modular design, allowing it to integrate seamlessly with various Dell server systems. It provides efficient data storage through its 3.5-inch drive bays, accommodating up to 15 hard drives or solid-state drives. This configuration not only facilitates higher storage density but also supports SATA and SAS drives, offering the flexibility to choose different types of storage media based on organizational needs.

The MD1000 features advanced RAID (Redundant Array of Independent Disks) technology, which enhances data protection and system performance. It supports multiple RAID levels, including RAID 0, 1, 5, 6, and 10, providing users with different options for balancing performance and redundancy. By leveraging RAID, the MD1000 ensures that data remains safe and accessible even in the event of hardware failure, significantly reducing downtime and risk.

Connectivity is another strength of the MD1000. It typically interfaces with a server through a variety of host interface options including iSCSI and Fibre Channel, making it adaptable to different network configurations. This connectivity flexibility supports various environments, ensuring organizations can scale their storage without significant infrastructure overhauls.

Cooling and power efficiency are also critical characteristics of the MD1000. It includes dual-redundant power supplies and cooling fans that not only enhance reliability but also lower operational costs. These components can function independently, ensuring that power loss in one does not affect overall system performance.

Management and monitoring capabilities of the MD1000 are empowered by the Dell OpenManage software, which provides a user-friendly interface to manage the storage subsystem. Users can easily monitor drive health, configure RAID settings, and receive alerts on potential issues, simplifying the administration of large storage networks.

Overall, the Dell MD1000 is built to accommodate growing storage needs while ensuring reliability, performance, and ease of use. With its modular design, support for various drive types, robust RAID capabilities, versatile connectivity options, and efficient power management, it represents an excellent choice for businesses looking to enhance their data storage infrastructure.