Atlas Sound FAP40T installation instructions Installation Instructions, AtlasSound.com, Screws

Page 1

FAP40T

INSTALLATION INSTRUCTIONS

Drop Tile Ceiling Installation:

1.Remove the 2'x2' or 2"x4' tile.

2.Align the tile bridge on the rear of the tile in the desired position.

3.Using the template provided mark the cutout circle with a marker and cut 6 5⁄16" hole.

4.Replace tile into grid.

5.Bring service loop from rear of the tile, through the tile bridge to the access panel located on the side of the Enclosure. Terminate the service loop to the barrier block connection provided.(Red dot = “+” please note polarity). A 7⁄8" through hole is provided to facilitate conduit. A UL recognized conduit connector should be used to terminate conduit. Connection cavity is not intended for use as a junction box.

6.Insert the enclosure through the front of the tile. Using a standard #2 Phillips screwdriver or screw-gun tighten the (3) dog leg assemblies until they engage the tile bridge assembly. DO NOT OVER TIGHTEN DOG LEG SCREWS!!

7.Adjust the front mounted switch to the desired tap setting. NOTE: A 8 ohm setting is included on the selector switch which bypasses the internal transformer for applications where the FAP40 is to be directly coupled to 8-ohm amplifiers.

8.Install the press-fit grille into the front bezel ring. Push the baffle upwards until the baffle is flush with the bezel ring.

9.For safety and seismic considerations, a suspension ring is integrated into the input panel section of the unit. Atlas Sound strongly suggests that a support wire be installed from this support point to a suitable anchor point above the ceiling grid. In drop tile applications, this wire can usually be installed from an adjacent tile access near the speaker location.

Existing Construction Dry Wall (“Hard Deck”) Installation

1.Using the template provided mark the cutout circle in the desired mounting location and cut 6 5⁄16" hole.

2.Bring service loop from through the hole to the access panel located on the side of the enclosure. Terminate the service loop to the barrier block connection provided (Red dot = “+” please note polarity). A 7⁄8" through hole is provided to facili- tate conduit. A UL recognized conduit connector should be used to terminate conduit. Connection cavity is not intended for use as a junction box.

3.Insert the enclosure into hole. Using a standard #2 Phillips screwdriver or screw-gun tighten the (3) dog leg assemblies until they engage the tile bridge assembly. DO NOT OVER TIGHTEN DOG LEG SCREWS!!

4.Adjust the front mounted switch to the desired setting. NOTE: A 8 ohm setting is included on the selector switch which bypasses the internal transformer for applications where the FAP40 is to be directly coupled to 8-ohm amplifiers.

5.Install the press-fit grille into the front bezel ring. Push the baffle upwards until the baffle is flush with the bezel ring.

New Construction (Drywall Ceilings)

Use of the optional FA-TR41new construction bracket essentially reserves the speaker mounting location prior to drywall instal- lation in new construction. The bracket mounts between 16" or 24" OC studs and includes a 3/8" downward lip to provide a template for the drywall installers to cut around. For final installation please follow the instructions below. Note: tile bridge is not used in new construction applications where the new construction bracket is utilized.

1.Bring service loop from through the hole in ceiling provided by the pre construction bracket to the access panel located on the side of the Enclosure. Terminate the service loop to the barrier block connection provided (Red dot = “+” please note polarity). A 7⁄8" through hole is provided to facilitate conduit. A UL recognized conduit connector should be used to termi- nate conduit. Connection cavity is not intended for use as a junction box.

2.Insert the speaker assembly into hole. Using a standard #2 Phillips screwdriver or screw-gun tighten the (3) dog leg assemblies until they engage the ring provided on the new construction bracket. DO NOT OVER TIGHTEN DOG LEG

SCREWS!!

3.Adjust the front mounted switch to the desired tap setting. NOTE: A 8 ohm setting is included on the selector switch which bypasses the internal transformer for applications where the FAP40 is to be directly coupled to 8-ohm amplifiers.

4.Install the press-fit grille into the front bezel ring. Push the baffle upwards until the baffle is flush with the bezel ring.

NOTE:

Dog legs will accommodate ceiling material thickness up to 1 1⁄4" as shipped from the factory.

For thicker ceiling materials (up to 2") simply un-screw and flip the doglegs.

DO NOT OVER TIGHTEN DOG LEGS IN EITHER CONFIGURATION!! *DO NOT USE 8 OHM SETTING WITH 70.7V/100V SYSTEMS!

*DO NOT OVERPOWER IN 8 OHM CONFIGURATION!

AMPLIFIER OUTPUT SHOULD NOT EXCEED 16W RMS @ 8 OHM PER SPEAKER

A UL recognized conduit clamp must be used for conduit connections. Cable connection cavity is not intended to be used as a junction box.

1FA-TR4 not tested or evaluated by Underwriters Labratories (UL)

Frequency Response: 120Hz-15kHzSensitivity: 86dB (1W/1M)

Specifications are subject to change without notice

AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •

TELEPHONE: (800) 876-3332

FAX: (800) 765-3435

©2004 ATLAS SOUND LP

Printed in U.S.A.

00403

ATS001529 RevD 3/04

PP

Image 1
Contents AtlasSound.com Installation InstructionsScrews Tap Selector Switch Position Amp Output 70.7V FAP40TINSTALLATION InstructionsTypical Parallel Hookup of Full Range 70.7/100V Speakers
Related manuals
Manual 4 pages 33.8 Kb

FAP40T specifications

The Atlas Sound FAP40T is an innovative ceiling speaker designed for commercial and professional audio applications. Renowned for its robust construction and advanced sound technology, the FAP40T stands out as a reliable choice for businesses looking to enhance their audio experience.

One of the key features of the FAP40T is its 4-inch full-range speaker driver, which delivers exceptional sound clarity and fidelity. This driver is engineered to provide a wide frequency response, making it suitable for a variety of audio needs, from background music to public address systems. The speaker’s ability to reproduce clear vocals and rich music makes it ideal for environments such as retail spaces, corporate offices, and educational institutions.

The FAP40T is equipped with a 70V/100V transformer, allowing for versatile installation options in larger spaces where multiple speakers are needed. This transformer not only facilitates long-distance audio distribution but also simplifies the process of connecting several speakers to a single amplifier. This characteristic enhances its scalability for various setups, making it an excellent choice for installations requiring extensive coverage.

Durability is another hallmark of the FAP40T. The speaker features a rugged, moisture-resistant design, which makes it well-suited for a variety of indoor environments. This construction ensures that the speaker maintains its performance over time, even in challenging conditions, thereby providing businesses with a long-lasting audio solution.

The FAP40T also incorporates a unique, easy-to-install system. It comes with a simple mounting mechanism that allows installers to securely fit it into the ceiling with minimal effort. This design feature reduces installation time and costs, making it a practical option for professional audio installations.

Additionally, the FAP40T is aesthetically pleasing, boasting a low-profile design that blends seamlessly into any ceiling. This ensures that it can enhance the audio experience without compromising the visual appeal of the environment.

In summary, the Atlas Sound FAP40T ceiling speaker combines high-quality audio performance, robust construction, and effortless installation. Its full-range driver, transformer capabilities, and durable design make it an ideal solution for commercial audio applications, allowing businesses to create a rich sound environment that enhances customer experience and engagement.