Cobra Electronics CPI 1550 warranty Troubleshooting Guide, Specifications, Solution

Page 12

Troubleshooting Guide

Operation

Troubleshooting Guide

 

 

 

Problem/Symptom

Possible Causes

Solution

Low output voltage

Overload

Reduce the load.

 

 

 

 

No output voltage

Low input voltage

Recharge battery.

 

 

 

Check connections

 

 

 

and cable.

 

No output voltage

Thermal

Allow inverter

after prolonged use

shutdown

to cool off.

 

 

 

Reduce load,

 

 

 

continuous

 

 

 

operation input

 

 

 

current required.

 

 

 

Improve ventilation;

 

 

 

Make sure ventilation

 

 

 

openings in the

 

 

 

inverter are not

 

 

 

obstructed.

 

 

 

Reduce ambient

 

 

 

temperature.

 

No output voltage,

High input

Make sure

“Protect” indicator

voltage

the inverter is

lighted

 

connected to

 

 

 

12V battery.

 

 

 

Check regulation

 

 

 

of charging system.

 

No output voltage

Short circuit

Check load for

 

 

 

proper operation.

 

 

 

No output voltage

Inverter

Turn inverter on.

 

 

 

switched off

 

 

 

 

No power

Check wiring

 

 

to inverter

to inverter.

 

 

 

Reverse

Observe

 

 

DC polarity

correct polarity.

 

Low battery alarm

Poor DC wiring

Check

on all the time

 

connections.

 

 

Poor battery

Make sure battery

 

 

condition

is fully charged.

Specifications

Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . 1500W Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 3000W Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88% Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83% No load current draw . . . . . . . . . . . . . . . . < 0.5A (12.6V) Output waveform (resistive load) . . . Modified sine wave Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V Operating temperature range . . . . . . . . . . . . 0°C – 40°C

(32°F – 104°F) Storage temperature range . . . . . . . . . . . . -40°C – 85°C (-40°F – 185°F)

Protection . . . . . . . . . .Overload, short-circuit, overtemp, reverse polarity, under/over voltage

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted after low voltage protection, the voltage of DC input should be above 12V.

To extend the life of the fan, it will stop when there is no load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for added safety.

18 English

Nothing comes close to a Cobra® 19

Image 12
Contents How Your Cobra Power Inverter Works Cobra line of quality products includesOur Thanks to You Hours a day, 7 days a week 773-889-3087 phoneProduct Features ContentsImportant Safety Information Important Safety InformationGeneral Precautions Cobra 1500 Watt Output Waveform Quick Evaluation Before Installation ≤ a 12 volt DC power source such as a vehicle batteryCheck to make sure all Connections are secure Plug in the test loadInstallation Requirements MountingConnecting Cables Connecting Cables not includedConnect cables to the power source Connect Cables Power Consumption Ground WiringPower Consumption Ground WiringRemote On/Off Switch On/Off Switch to on On/Off Switch to offRemote On/Off Switch not included Operating Limits Power Output Operating LimitsInput Voltage Troubleshooting Guide SpecificationsTroubleshooting Guide SolutionWarranty and Trademark Acknowledgement Maintenance Product ServiceAccessories Order Form Qty Amount