Bacharach FT-10 manual Operating Notes

Page 18

LED 1 and LED 2 will normally show activity about every 15 seconds. Since the refrigerant monitoring process is fairly slow and new data is only available every 15 seconds or so, the adapter polls the HGM at a slow rate to reduce the communications burden on the HGM main processor. Again, commands coming in from LonWorks might occasionally cause LEDs 1 and 2 to blink more frequently.

Operating Notes

Before changing alarm thresholds through nviSetZoneThresh, go ahead and set nviGetZoneThresh to the zone you are about to modify. Then nvoHgmZoneThresh will update automatically with the current thresholds for that zone every time new information is available from the HGM300.

Please note that it could take as much as 30-40 seconds before the changes made through nviSetZoneThresh can be seen on nvoHgmZoneThresh. The adapter must get the changes from LonWorks and pass the new thresholds down to the HGM. The HGM then takes a certain amount of time to process the changes and store them in its nonvolatile memory. Then, since the HGM is not polled continuously, a certain amount of time is needed to pick up the new threshold settings and pass them back up to LonWorks. Please be patient waiting for changed alarm thresholds to show up in nvoHgmZoneThresh. Fortunately changing alarm thresholds is done infrequently after initial installation and setup.

If the adapter is moved to a new LonWorks network where the old addressing information would be invalid, the adapter can be set back to its initial Unconfigured state. This is accomplished by holding the Service button down, powering up the adapter, and continuing to hold the Service button down for 10 seconds. When the Service button is released, the Service LED will flash, showing that the LonWorks portion of the adapter is now Unconfigured. This is the desired state for installing the adapter on a new LonWorks network.

18 of 18

Image 18
Contents Adapter Installation Inside HGM300 IntroductionPage Page Page Setting HGM Communication Address On Adapter Page Configuring the HGM300 with RDM800 or Laptop PC External Interface XIF and User Resource FilesIdentifying the HGM300-LonWorks Adapter on the Network HGM Alarm Acknowledge Options LonWorks Objects and Network Variables Object 0 The Node ObjectPage Objects 1-16 Zone Objects HGM Busy Object 17 General Status Object Page Object 18 Alarm Control Object Page Operating Limitations When Using RDM800 Remote Display Communications LED IndicatorsOperating Notes

FT-10 specifications

The Bacharach FT-10 is a state-of-the-art portable gas leak detector designed to monitor the presence of combustible gases, making it an essential tool for professionals in HVAC, refrigeration, and gas utility industries. Recognized for its reliability and accuracy, the FT-10 employs advanced sensor technologies to provide quick and precise measurements of flammable gases.

One of the main features of the FT-10 is its innovative infrared sensor, which allows for the detection of various gas types, including methane, propane, and butane. This technology ensures that the device can identify gas leaks quickly, enhancing safety in residential and commercial environments. The FT-10 features a user-friendly interface, complete with a clear LCD display that provides real-time readings and visual indicators. This makes it easy for technicians to interpret data quickly, even in low visibility situations.

The device is built for durability and portability, weighing just a few pounds and designed to withstand harsh working conditions. Its compact size allows for easy handling, making the FT-10 ideal for fieldwork. Additionally, it is equipped with a robust battery that offers extended operational time, ensuring that professionals can rely on it during critical situations without worrying about frequent recharging.

Another notable characteristic of the FT-10 is its built-in data logging capability. Users can store measurement data for later analysis, which is crucial for documentation and compliance purposes. The device also features customizable alarm settings, providing audible and visual notifications when gas concentrations exceed predetermined safety levels. This feature enhances user safety, allowing immediate action to be taken to mitigate risks.

Moreover, the FT-10 is designed with user comfort in mind. The ergonomic shape fits comfortably in hand, and the controls are strategically placed for easy accessibility during operation.

In conclusion, the Bacharach FT-10 gas leak detector amalgamates advanced sensor technologies, durability, and user-friendly features into one comprehensive package. It stands as a trusted ally for technicians who prioritize safety and efficiency in their work, ensuring they can respond promptly and effectively to gas leak incidents.