Mustek PP3000 manual ON/X-OFF Mode, Mechanical error

Page 38

TM

CHAP. 4

TECHN

out”, load paper into the printer and press the “ON LINE” switch to set the printer to “ON LINE”.

Mechanical error

Mechanical errors are detected when the motor locks or else and the unit will not print. Immediately after a mechanical error occurs, the printer sets the DTR to “MARK” and then sets the printer to “OFF LINE”. To cancel a mechanical error, close the front cover properly and press the “ON LINE” switch. If the buzzer sounds and the “ALARM” LED flashes at this time, then locate the cause of the error and turn the power for the printer off and back on again to reset the printer.

Framing error

A framing error occurs when “SPACE” is detected at the stop bit. When a framing error or a vertical parity error occurs for the data which is received, the printer prints out a “?” mark to indicate that the error occurred.

Cash drawer open detection switch

When pin 6 of the peripheral unit drive circuit connector is set “HIGH”, status bit 7 becomes “1”.

X-ON/X-OFF Mode

This mode is accessed when the DIP switch 1-5 is OFF. If printer errors do not occur after the power is turned on, the printer outputs an X-ON (DC1 by control code; 11H by hexadecimal data) signal on the TXD signal line of the printer which sends it to the host computer. When the host computer receives the X-ON signal, the host computer transmits the data to the RXD signal line of the printer. If data text is not sent from the host computer (even after transmitting the X-ON signal to the host computer), the printer outputs an X-ON signal at 3 second intervals until the printer receives data. The printer starts outputting an X-OFF (DC3, 13H) signal when the empty space in the buffer reduces below 256 bytes. When the host computer receives the X-OFF signal, it halts output of data (however, the printer can continue receiving data until the buffer becomes

4 - 10

Image 38
Contents POS Printer Manual Rev.BEC Council Directive 89/336/EEC of 3 May Warranty LimitsCE manufacturer About This ManualPage Page Table of Contents Data Structure in Serial Interface · · · · · · · · · · Iii Other Control Codes · · · · · · · · · · · · · · · · · 7 Appendix C Page General Description Overview Model NumbersFeatures Unpacking Contents Basic MountingMounting printer to PST For Other System Cable ConnectionsLoading Ribbon Cartridge Cable connection examplesLoading ribbon cartridge Loading Paper OFFGrooves on paper guide shaft Removing The Roll Paper Putting spacer to roll paper shaftPower LED green On Line switchFeed switch Alarm LED redLocations of switches and LED’s Self Print TestSelf print sample Micro Feed Hexadecimal Dump ModeClear Print Buffer Validation PrintingOperation Method Validation printingPaper Format Printing FormatData Format Other ConsiderationsPeripheral Unit Drive Circuit Telephone jack and plug for peripheral unit driveChap OPERA… Block Diagram Circuit block diagramCircuitry Layout & Connectors Board layoutCN9 Printer power input connector Serial Interface Switch Jumpers & SwitchesJumper Setting Interface Select USA OFFON/ OFF DIP-SW Character code table DIP-SW ModeAddress selection for addressable mode #10 #11 #12 #13 #14 DIP-SW3 Parallel Interface Switch DIP-SW1DIP-SW DTR Mode Data Structure in Serial InterfaceON/X-OFF Mode Mechanical errorStatus STX-ETX Mode RET Chap TECHN… Interface Parallel InterfaceBusy Serial Interface Peripheral Unit DriveFont Matrices Power SupplyOption List CaseCharacter size 15 CPI 12 CPI CPIWeight CommandsExternal Dimensions Operating EnvironmentCleaning Paper JAMTrouble Shooting Control Codes Hex Codes Function Star Compatible ModeControl Codes for Character Setting Control Codes for Line Spacing Control Codes for Page LayoutControl Codes for Graphics Printing Control Codes for Download CharactersBasic Reference Control Codes for Peripheral UnitsOther Control Codes Hardware Modification RequiredUnsupported Control Codes Reference Epson Models EmulatedCharacter Size/Font Matrices Supported Control CodesESC SP APP. a Star … Codes HEX/CONTROL 09 / HT Function Line feedCodes HEX/CONTROL 07 / BEL Codes HEX/CONTROL 0A / LFCodes HEX/CONTROL 0E / SO Codes HEX/CONTROL 0C / FFCodes HEX/CONTROL 0D / CR Codes HEX/CONTROL 0F / SIFunction Cancel inverted print mode Codes HEX/CONTROL 12 / DC2Codes HEX/CONTROL 18 / can Codes HEX/CONTROL 13 / DC3Codes HEX/CONTROL 14 / DC4 Codes HEX/CONTROL 19 / EM Function Immediate drive command for peripheral unitDefinition Range 1 ≤ n1 ≤ 127, 1 ≤ n2 ≤ Codes HEX/CONTROL 1A / SUBAPP. a Star … Codes HEX/CONTROL 1B 26 00 n1 n2 / ESC & 0 n1 n2 APP. a Star … Codes Definition Range 1 ≤ n ≤Codes HEX/CONTROL 1B 40 / ESC @ Function Initialize printer Codes HEX/CONTROL 1B 3A / ESCFunction Select 8 CPI character size Definition Range 0 ≤ n ≤ 85 Default n = Definition Range 1 ≤ n1 … nk ≤ 255, 1 ≤ k ≤Definition Range 1 ≤ n1 … nk ≤ 39, 1 ≤ k ≤ Function Select emphasized print modeFunction Cancel emphasized print mode Codes HEX/CONTROL 1B 45 / ESC ECodes HEX/CONTROL 1B 4B n1 00 / ESC K n1 Definition Range 1 ≤ n1 ≤Definition Range 1 ≤ n1 + 256 x n2 ≤ Function 8 dot single density bit imageCodes HEX/CONTROL 1B 4D / ESC M Definition Range 0 ≤ n ≤ 255 Default n =Detail Description Cancel bottom margin Codes HEX/CONTROL 1B 4F / ESC OFunction Select 12 CPI character size Definition Range 00H ≤ n ≤ 0AHCodes HEX/CONTROL 1B 50 / ESC P Codes Function Detail Description Cancel overline mode Detail Description Cancel vertical expanded character mode Definition Range 0 ≤ n ≤ right margin Function Set left marginCodes HEX/CONTROL 1C / FS Codes HEX/CONTROL 1E / RS Function Sound buzzer