Monarch 9460 manual T t i n g S t a r t e d

Page 10

G e t t i n g S t a r t e d

1. Start the ADK2 software. You will see

Project Tree

Working Area

 

Builder Output

The screen has three major sections: the Project Tree, Working Area, and Builder Output. You can use the View menu to change which areas appear on your screen.

The Project Tree lists all the files in the open project. See “About Projects” for more information.

The Working Area is the text editor for the files in the project.

The Builder Output lists any errors or messages that appear when you build the project.

2. Start a new Project: Select N ew from the Project Menu.

3. Enter a name for the Project. Press f. You will see the Project Properties screen.

4. Accept the default directories or change the directories.

5. Select 9460 from the Printer Type box. Press f. The project file structure is set up. You return to the Main screen.

2-2Using the Software

Image 10
Contents Monarch 9460 ADK Printer Trademarks TA B L E O F C O N T E N T S Command Reference Table of Contents Sample Script W t o U s e t h i s M a n u a l E v i e w o f T e r m s2Overview S t e m R e q u i r e m e n t s Install i n g t h e S o f t w a r eN n e c t i n g t h e P r i n t e r T t i n g S t a r t e d Page V i n g a F i l e O u t P r o j e c t sI l d i n g P r o j e c t s A n g i n g t h e D o w n l o a d S e t t i n g sIf you select COM1 COM4 If you select LPT1 LPT2I t i n g E x i s t i n g P r o j e c t s W n l o a d i n g a P r o j e c tIf you select Tcpip 8Using the Software S p l a y i n g t h e R e a d y P r o m p t C e s s i n g t h e T o o l b oA d i n g a p p l i c a t i o n s Choose Tool BoxBegin N c t i o n sEND L e s a n d B u f f e r s A r t i n g a S c r i p tFunction Start Begin O p e o f F i e l d N a m e s ADD Control , TEMP1 , *ERROR2, *SUCCESS2R i p t F l o w C o n t r o l T a S t o r a g e M m e n t s i n a S c r i p tT a C o d i n g O g r a m m i n g C o n v e n t i o n s E l d N a m e sY w o r d s Command Reference E c i a l C h a r a c t e r s When a label is definedWhen a label is not defined R i p t F l o wR i p t C o n t r o l C o m m a n d s N c t i o n a l R e l a t i o n s h i p sT h C o m m a n d s M p i l e r D i r e c t i v e sT a M a n i p u l a t i o n C o m m a n d s L e M a n a g e m e n t C o m m a n d s P u t / O u t p u t C o m m a n d sExample ADD CONTROL,TEMP1,*ERROR2Buffer-field 1 ADD WHOLESALE,TEMP2P V E R S I O N Appversion AP11, VERIndex G R E a DRaw-Data, Destination, Argread PARAMLIST, PARAM1, #1Int-field only ASC int-field,asc-fieldInt-field and Asc-field ASC TAINT, TaasciiT O S T a R T AutostartDevice A I L a B L E D a T aAvailabledata device , invalid label , valid label Availabledata COMM, , *CHARLNAsc-field and Int-field T C L E a RBitclear TEMP1, #2 Buffer-field1 and Buffer T M a S KOperation Field2Buffer-field T S E TBoth buffer-field1 and bit-position must be numeric Bit-positionBuffer-field1 and count T S H I F TDirection Bitshift LEFT, TEMP1, #1Buffer-field1 T T E S TBittest TEMP1, #2, *CLEARED Bsearch lookup-field,value , invalid label , valid label Bsearch CONTROLID, INPUT, *ERRORIDE a R C H ValueParam L LCall function-name param1, param2, …,paramX Call ComputetaxEND Function Addnum Begin Function StartCall ADDA R T Y P E Chartype type , buffer-field1Using type and buffer-field1 TypeCheck item , buffer-field , invalid label , valid label E C KValue Description Check BATTERY, *LOWBATTERY CHR asc-field,int-field CHR TAASCII, TaintClear Printer E a RClear TEMP1 Commport O S E C O M MClosecomm #1 No valid label M P a R EModifier Is no invalid labelSource and Destination N C a TConcat SKU,BCFIELD Buffer2 T R I PField-buffer1 and Field Field-buffer2 onlyData-type T a T Y P EDatatype Alphanumeric Buffer Field DEC buffer-field , invalid label , valid labelDEC Tempsku F I N E Define TEMPORARY,CURRQTY,4,N Delay Timeout Delay #intervalDelay #20 L a YHotkey1, Hotkey2, Disable F1, F2, F3S a B L E Hotkey3V I D E Divide CONTROL,TEMP1,*ERROR2Divide PRICE,#100,*ERROR2 Buffer Field1Enable F1, F2, F3 A B L EI T ExitFetch src1 , src2 , invalid label , valid label T C HSrc1 and Src2 E L D L E N Fieldlen WHOLESALE,TEMP2X D a T a Fixdata buffer-field1Buffer-field and Type N E R a T EGenerate INPUT, #2 Minimum and Maximum ExamplefKey T K E YHotkey key, function-name Hotkey F3, QuerylookupElseif buffer-field2 comparison buffer-field4 Buffer-field1 comparison buffer-field2Buffer-fields Comparison Description INC buffer-field , invalid label , valid label INC COUNT01Include TRUCKIN.ULT C L U D EInclude C\PROGS\SAMPLE\SPECIAL.ULT Overwrite-flag S E R TPosition M P Jump *REQUESTSKULabelcount buffer-field1 , invalid label , valid label B E L C O U N TLabelcount Numoflabels Left SHIPNO,SKU,#5 F TLeft SHIPNO,SKU,NUMCHARS N K F I L E Linkfile CHCKDGIT.PKTRow-position and col-position can be one of the following C a T ELocate row-position, col-position SourceW E R Lower TempskuField-buffer1 and Field Buffer2 only Field-buffer1, FieldBuffer2, and Field Buffer3 Field-buffer3 onlyMacro-body C R OMacro macro-name Defining the MacroCompare Macro Ptridle Begin Move CheckMove PIEND$ Buffer-field1, start, Length only Buffer-field1, 2, StartMID LOCATION,TEMP1,#5,#5 V E Move source, destination , invalid label , valid labelDestination Move INPUT,CONTROLIDMultiply buffer-field1 ,buffer-field2 , invalid label Multiply PRICE,TEMP1,*ERROR2L T I P L Y Valid labelCommport and Timeout Opencomm commport, timeoutE N C O M M Max-length Pad-field, Pad-characterPAD L,PRICEFIELD,*,LPRICE Parse invalid label , valid label R S EParse Quantity I N TFormat-number Format-number and quantity must be numericComparison E R YBuffer-field2 Is numeric, buffer-field2must be numeric Command again to ensure a valid record pointerRule Control passes to the *PROCESSIDRecord A DRead record table-name , invalid label , valid label Read LookupClear Display Move RestorescreenS T O R E S C R E E N Savescreen Clear Display MoveCompare FSIZE,EQ,#12,,*GOODDATA T U R NReturn Buffer-field1, 2 G H TRight buffer-field1 ,buffer-field2 ,length , invalid label Right SHIPNO,SKU,#5Length Buffer-field1,Buffer-field2Rstrip SHIPNO, SKU, #5 V E S C R E E N SavescreenFile-type E KTo modifier Seek NEXT,LOOKUPFILE,*EOFLABELSUB CONTROLID,TEMP1 Switch buffer-field1 Case buffer-field I T C HWhile Sysset function, parameter1, parameter2 S S E TFunction/Description Parameter1 Parameter2 192 * width in inches 192 * length in inches Sysset PROMPTS, #1Token Delimeter character , invalid label , valid label K E NCharacter, buffer-field1 Buffer-field1 and Buffer-field2 Buffer-field1 and buffer-field2 can be one of the followingBuffer-field2 only P E R Upper TempskuSource and Type L I D a T EValidate source, type Invalid label , valid label Validate Input #2I L E While buffer-field1 comparison buffer-field2Ptridle WhileEndwhile 88Command Reference M P L E S C R I P T Concat Concat 13,~034FISHING ROD~034, ScratchConcat R,1,~034MIAMISBURG OH 45342~034, Scratch ScratchScratch Concat Concat R,1,~034170 Monarch LANE~034, ScratchDEPT#25~034, Scratch D E Page Page Index

9460 specifications

The Monarch 9460 is a cutting-edge printing solution designed to meet the needs of modern businesses and industries. This advanced printer combines high-performance capabilities with user-friendly features, making it an ideal choice for various applications, from industrial printing to high-volume document production.

One of the standout features of the Monarch 9460 is its exceptional printing speed. Capable of producing thousands of labels per hour, this printer is engineered to handle large-scale printing tasks efficiently. This speed does not compromise print quality; the Monarch 9460 delivers sharp, crisp images with precise color reproduction, ensuring that labels and documents are not only produced quickly but also look professional.

The Monarch 9460 employs advanced thermal transfer printing technology, which allows for high-resolution output that is resistant to smudging and fading. This durability is particularly important for labels that need to withstand harsh environments or extended periods of use. Additionally, the printer supports a variety of media types and sizes, making it versatile and adaptable to different printing needs.

Another key characteristic of the Monarch 9460 is its robust connectivity options. The printer supports multiple connectivity methods, including USB, Ethernet, and wireless options, allowing seamless integration into existing workflows and systems. This flexibility is crucial for organizations looking to streamline operations and improve productivity.

User convenience is also a priority with the Monarch 9460. Its intuitive control interface, complete with a color touchscreen display, simplifies the printing process, reducing the learning curve for new users. The printer also offers easy maintenance features, such as straightforward access to replace consumables, minimizing downtime and ensuring consistent performance.

In terms of software integration, the Monarch 9460 is compatible with a variety of printing software solutions, making it simple to incorporate into any automated system. It can also connect to various databases for dynamic label printing, enhancing efficiency in applications such as inventory management and shipping.

In summary, the Monarch 9460 stands out as an exceptional printing solution that combines speed, quality, versatility, and user convenience. Its advanced technologies and features make it a valuable asset for businesses looking to enhance their printing capabilities in a competitive landscape. Whether for high-volume label production or professional document printing, the Monarch 9460 is engineered to deliver remarkable performance consistently.