Measurement Specialties PMD-1024HLS manual Specifications, Digital input/output

Page 19

Chapter 4

Specifications

Typical for 25 °C unless otherwise specified. Specifications in italic text are guaranteed by design.

Digital input/output

 

 

Table 4-1. Digital I/O specifications

 

 

 

Digital input type

 

74ACT373

Digital output type

 

74FCT244

Number of I/O

 

24 (port A0 through port C7)

Configuration

 

2 banks of 8 and 2 banks of 4 or

 

 

 

3 banks of 8

 

 

 

Pull up/pull-down configuration

 

Internal 47K resistors may be user configured for pull-up or pull-down via

 

 

 

external connection of "Port x Pull-up / Pull-down" to "USB +5 V" or

 

 

 

"GND". Ports A, B, and C are independently configurable.

Input high voltage

 

2.0 V min, 5.5 V absolute max

Input low voltage

 

0.8 V max, –0.5 V absolute min

Output high voltage (IOH = -15 mA)

 

2.4 V min

Output low voltage (IOL=64 mA)

 

0.55 V max

Source current – (Note 1)

 

Maximum = 15 mA per output

ƒ

Self -powered hub

 

 

ƒ

Externally-powered root port hub

 

 

Source current – (Note 2)

 

Per pin maximum = 40 mA/ [number of active outputs].

ƒ

Bus-powered hub

 

15 mA max source current for any single output

ƒ

Battery-powered root port hub.

 

 

Sink current - (Note 3)

 

Current sink max: 440 mA/ [number of outputs].

 

 

 

64 mA max sink current for any single output.

Power up/reset state

 

Input mode (high impedance)

Note 1: "Self-powered hub" refers to a USB hub with an external power supply. Self-powered hubs allow a connected USB device to draw up to 500 mA. "Root port hubs" reside in the PC’s USB Host Controller. The USB port(s) on your PC are root port hubs. All externally powered root port hubs (i.e. desktop PC’s) provide up to 500 mA of current for a USB device. In this configuration, all 24 digital outputs of the PMD-1024HLS can source their per-pin maximum of 15 mA. This provides a total requirement of 15 mA*24 = 360 mA. Combining this with the PMD-1024HLS operating current of 60 mA a fully-loaded current draw of 420 mA is realized.

Note 2: "Bus-powered hub" refers to a USB hub that derives power directly from the USB +5 V and does not have its own power supply. These hubs allow a connected USB device to draw up to 100 mA. Battery-powered root port hubs provide 100 mA or 500 mA, depending upon the manufacturer. A laptop PC that is not connected to an external power adapter is an example of a battery-powered root port hub. If your laptop is constrained to the 100 mA maximum you have two options when using a PMD-1024HLS. In order to take advantage of the full drive capability of 15 mA per pin you will need to purchase a self-powered hub. Otherwise the total output drive must be de-rated. When de-rated, the total available source current for the digital outputs is the difference between the unloaded operating current of the PMD-1024HLS (60 mA) and the 100 mA overall maximum.

Note 3: A low-side resettable fuse protects the PMD-1024HLS. This is designed to protect the host PC or hub from an over current condition. Assuming all return currents in sinking applications return via the USB cable ground signal, the maximum allowable return current is 500 mA. Please include the PMD-1024HLS unloaded operating current (60 mA) in your power budget.

4-1

Image 19
Contents Page PMD-1024HLS Management committed to your satisfaction Trademark and Copyright Information Table of Contents Conventions in this users guide Where to find more informationAbout this Users Guide What you will learn from this users guideChapter Introducing the PMD-1024HLSSoftware features PMD-1024HLS block diagramConnecting a PMD-1024HLS to your computer is easy Software Installing the PMD-1024HLSWhat comes with your PMD-1024HLS shipment? HardwareDocumentation Installing the software Installing the hardwareBe sure you are using the latest system software Unpacking the PMD-1024HLSIf the LED turns off Functional Details USB connectorExternal components Main connector and pin out Screw terminal wiringScrew terminal pins False For more information on digital signal connections Power terminalsOutput sink current limits Counter terminal Ground terminalsPull-up/pull-down terminals Pull-down connection for Port a Digital input/output SpecificationsCounter section PowerMechanical Main connector and pin outGeneral EnvironmentalUSA Declaration of ConformityMailinfo@mccdaq.com