DEFINITIONS FOR LED INDICATORS

Indicator

Sound/Alarm

Situation

LED 1 (Green)

 

Mains normal,

Illuminated

No sound

Input power source is supplying the load

LED 2

(Yellow)

 

Mains normal,

Illuminated

No sound

Battery is charging

LED 3

(Red)

Beeps every two

Mains abnormal,

Illuminated

seconds

Battery is supplying the load

LED 3

(Red)

Beeps every one second

Mains abnormal,

Illuminated

Battery is low

LED 3

(Red)

 

Battery exhausted,

Illuminated

Continuous beeping

UPS will protect itself and switch off

No LED's

 

UPS shutdown,

Illuminated

No sound

In sleep mode

TROUBLESHOOTING

Problem

Possible Cause

Solution

 

 

 

Full-time surge

Fuse has tripped due to an

Turn the UPS off and unplug at least

protection outlets

overload.

one piece of equipment. Wait 10-

stop providing power

 

seconds, replace the fuse with a fuse

to equipment.

 

of like size and rating, and then turn

 

 

the UPS on.

The UPS does not

Battery not fully charged.

Recharge the battery for at least 4-

perform expected

 

hours.

runtime.

 

 

The Battery is defective.

Contact MINUTEMAN UPS about

 

 

 

replacement batteries at

 

 

mmsupport@minutemanups.com

The UPS will not turn

The on/off switch is

Turn the UPS off. Wait 10-seconds

on.

designed to prevent

and then turn the UPS on.

 

damage by rapidly turning

 

 

it off and on.

 

 

The UPS is not plugged

Connect the UPS to an 110/120V

 

into an AC wall outlet.

60Hz AC wall outlet.

 

The battery is defective.

Contact MINUTEMAN UPS about

 

 

replacement batteries at

 

 

mmsupport@minutemanups.com

 

Mechanical problem.

Contact MINUTEMAN UPS at

 

 

mmsupport@minutemanups.com

The UPS shuts down

The UPS is not providing

Shutdown your computer and turn

when there is a loss

battery power.

the UPS off. Wait 10-seconds and

of AC power.

 

turn the UPS back on. This should

 

 

reset the UPS.

6

Image 7
Contents MM-AVR UPS Series User’s Manual Table of Contents Description Important Safety Instructions Save These InstructionsHardware Installation Guide Battery Replacement Procedure Replacing the BatteryPage Troubleshooting Definitions for LED IndicatorsAC mode follow utility Specifications15.4Lbs 16.5Lbs 28.7Lbs Net Weight Kgs If the UPS requires Service Obtaining ServiceLimited Product Warranty