Paradox Hellas S.A CAA470A-EI02 manual CA-A470-A indicators, Connection drawing of the CA-A470-A

Page 2

Figure 5: CA-A470-A indicators

Figure 6: Connection drawing of the CA-A470-A

Green “STATUS” LED:

Flash = Module OK

Slow flash = Communication failure (see also “COMM” LED)

Green “LOCK#1” and “LOCK #2” LEDs:

ON = Relay activated.

Green “AC” LED:

ON = AC power

OFF = Power failure

Green “AUX” LED: ON = Auxiliary power

OFF = Auxiliary power failure

Red “COMM” LED:

ON = Communication failure

OFF = OK

Green “CHECK BATT” LED: ON = Battery verification in

progress (every minute)

Red “BATT TRBL” LED:

ON = Battery low or disconnected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green “READER#2 DATA” and “READER#1 DATA” LED:

 

 

 

Long flash = Receiving card read

 

 

 

Red “TX” LED and green “RX” LED:

Short flash = Receiving card read, but the system

ON = Communication OK (may flicker)

does not recognize the card’s format

OFF = Communication failure

OFF = Not receiving card read

 

 

 

The reader LEDs can be used to verify the reader’s connections and programming. If no flashing occurs when a card is presented to the reader, the reader may be installed incorrectly. A short flash indicates that the reader is correctly installed, but the card is the wrong type or that the reader was incorrectly programmed.

Warranty

Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold.

Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty.

BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller.

© 2001-2004 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259, 5886632. Canadian and international patents may also apply.

Centaur is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.

Image 2
Contents DIP Switches 350mA/700mA Battery Charging JumperSpecifications IntroductionCA-A470-A indicators Connection drawing of the CA-A470-A