Opticon
OPL 9712
Specifications Manual
5. Electrical Specifications |
| ||
| Item | Specifications | Remarks |
|
|
|
|
| Main battery | 600 mAh |
|
|
|
|
|
| Main battery life | Rechargeable: 300 times |
|
|
|
|
|
| Backup battery | 3.4 mAh |
|
|
|
|
|
| Current consumption | 1 mA or less | At standby |
|
|
|
|
|
| 150 mA or less | When operating |
|
|
|
|
| Usable time | 24 hours or more | 1 scan/5s |
|
|
| Without backlight, with Bluetooth communication |
|
|
|
|
|
| 50 hours or more | 1 scan/5s |
|
|
| Without backlight, no communication |
| Data hold time | 72 hours or more | After main battery discharged |
|
|
|
|
6. Functionality
Item |
| Specifications | Remarks | |
|
|
|
| |
| MPU | Manufactured by | ||
Control section | Toshiba | |||
|
| |||
|
|
| ||
| Clock frequency | 14.74 MHz |
| |
|
|
|
| |
External memory | Flash ROM | 512 KB | For BIOS/AP | |
|
|
| ||
SRAM | 512 KB | For WORK/DATA | ||
| ||||
|
|
|
| |
| LCD |
| ||
|
|
|
| |
| DPI | 112 x 64 dpi |
| |
Display section |
|
|
| |
Backlight | Installed |
| ||
|
| |||
|
|
|
| |
| Functions | Clock time, battery power, failure notification, |
| |
| function settings |
| ||
|
|
| ||
Clock section | Real time clock | Counts year, month, date, hour, minute of the |
| |
current time and corresponding to leap years |
| |||
|
|
| ||
|
|
|
|
7. Optical Specifications
Parameter | Specification | Unit |
|
|
|
Red laser diode | - | |
|
|
|
Emission wavelength | 650 ±10 (25° C) | nm |
|
|
|
Light output | 1.0 or less | mW |
|
|
|
Scanning method | - | |
|
|
|
Scanning speed | 100 ±20 | scans/s |
|
|
|
Scan angle | Scan angle: 54 ±5 | ° |
|
|
|
| Read angle: 44 (Min) | ° |
|
|
|
Resolution | 0.15 or more | mm |
|
|
|
8