SYSTEM GAIN

Input sensitivity is adjusted (counterclockwise reduces sensitivity) through a rear panel mounted trim control. Adjustment range is from -30dB to +6dB. Factory preset gain is +6dB, which should suffice for most conditions. Normally adjustments would only be made if you’re using your V-4 in a surround system and you need to balance levels or if your monitor send is too hot and not adjustable. If an adjustment is necessary, you’ll need a small flathead screwdriver and some measuring equipment. (E.g. tone or filtered noise generator and SPL meter)

Connecting Your System

POWERING ON

All connections should be made, all faders and controls should be set at their minimum levels, and all other equipment should be powered on prior to powering on your V-4 monitors.

The power On/Off switch is located on the rear panel and is internationally marked to indicate the operational status. ( ) = ON and ( O ) = OFF. A yellow LED illuminates the trademarked KRK Triangle on the front baffle when power is applied.

NOTE: MAKE SURE THAT THE VOLTAGE INDICATOR FOUND IN THE MIDDLE PORTION OF THE IEC MAINS CONTROL IS SET TO THE CORRECT VOLTAGE SETTING FOR YOUR VOLTAGE.

CHANGING VOLTAGE

To change the voltage, remove the power cord, pry off the fuse block with a small flathead screwdriver (look for indent on the left inside of the power cord insert). Slide the circuit board out of the fuse block, rotate 180º and reinstall the fuse block. Please note when making fuse changes, the fuses will have to be replaced. (see

Changing Fuses section below) Make sure and align the white arrow with the raised arrow located on the power entry module before reinstalling. Check to see if the correct voltage can be read from left to right in the voltage window before powering up.

CHANGING FUSES

Under normal operation the fuses should not blow. A blown fuse usually indicates an overload or fault condition. To change the fuse, remove the power cord, pry off the fuse block with a small flathead screwdriver (look for indent on the left inside of the power cord insert) and change the blown fuses.

100~120VAC use 2 amp 250V 5mm x 20mm fuses

220~240VAC use 1 amp 250V 5mm x 20mm fuses

If the fuses blow immediately upon power up, this indicates a fault condition and the monitor should be returned to KRK for repair.

2

Image 3
Contents User Guide Contents IntroductionSystems Controls Changing Voltage Connecting Your SystemPowering on System GainChannel SET-UP Installing Your MonitorsNeutrik Combo Connector Positioning Your MonitorsSubwoofer SET-UP Channel Surround SET-UP System Highlights Design GoalsProblem If there is no power, check to see if TroubleshootingProblem The monitor hisses, hums or makes other loud noises V-4 Powered Studio Monitor SpecificationsSafety Instructions English Explanation of graphical symbols Avertissement Consignes de Securite FrancaisExplication des symboles graphiques