Lexicon 20/20 AD manual These instructions are for use by qualified personnel only, Word Clock

Page 14

Using the 20/20 AD

Lexicon

 

CAUTION

These instructions are for use by qualified personnel only.

Before opening the 20/20 AD, REMOVE THE POWER CORD. You may be exposed to hazardous voltages even if power to the unit is turned off.

WARNING

Turn off power and REMOVE THE POWER CORD

before opening the unit.

Take a moment to study the figure below. This diagram shows the terminating and grounding of input signals for the unit, and explains the function of most of the jumpers on the 20/20 AD Main pc board. The configuration shown illustrates the jumper settings when the 20/20 AD is shipped from the factory.

 

XLR

 

CHASSIS GROUND

 

 

 

 

 

 

 

 

CONNECTOR

ANALOG IN

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

W1

 

 

 

 

 

W9

 

 

 

2

 

+

 

 

 

 

W11

 

 

 

3

 

-

XLR

 

 

600 OHM

W13

 

 

W2

 

 

CONNECTOR

 

 

W10

 

 

 

AES OUT

 

 

W12

 

 

 

 

 

 

W14

 

 

 

 

 

 

 

 

 

 

1

SHIELDED

 

 

 

 

W26

2

 

 

 

 

W27

3

TWISTED PAIR

 

 

 

 

 

 

 

 

AES SYNC IN

 

 

 

SHIELDED

 

 

 

 

 

 

 

 

 

 

 

 

TWISTED PAIR

 

 

1

 

 

W18

 

 

 

2

 

 

 

RCA

 

 

3

 

 

 

CONNECTOR

 

 

 

 

 

S/PDIF OUT

 

 

W17 110 OHM

 

 

 

XLR

 

 

 

 

 

 

CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

75 OHM

 

BNC

 

 

 

SYSTEM GROUND

COAXIAL

 

 

 

 

 

 

CONNECTOR

WORD CLOCK IN

 

 

 

 

 

 

 

 

 

J13

 

 

 

 

 

 

 

 

75 OHM

 

W16

 

 

 

 

COAXIAL

 

 

 

 

 

 

 

75 OHM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHASSIS CONNECTED TO

 

 

 

 

 

 

EARTH GROUND

 

 

 

 

 

 

THROUGH POWER CABLE

 

 

 

 

 

 

OR GROUND STRAP

Jumper settings

(as set at the factory)

10

Image 14
Contents 20/20 AD Precautions Electrostatic Discharge ESD Precautions Contents Introduction AES/EBU Interface ProfessionalControls and Connectors Power Mounting20/20 AD Front Panel Controls ConverterDisplay Level MetersCompressor LinkPress and hold Then press one of these Synchronization Output FormattingAlternate Modes 20/20 AD Rear Panel Connectors BAL/UNBAL XLR Pinout Connectors Audio Connections Cables Termination and Grounding via Internal Jumpers Signal Type Attenuator DBu DBVSignal Type Pin Pin3 These instructions are for use by qualified personnel only Word ClockAnalog Jumpers Balanced Unbalanced Input Signals Meter Ballistics Front panel AdjustmentsDB Scale Synchronization and Sample Rate AES Sync Word ClockStates Internal and External modesAbout Dither Psychoacoustically Optimized Noise Shaping Pons00k 10.0k 12.0k 14.0k 16.0k 18.0k Automatic Offset Removal Compressor Modes Dynamic Range CompressionInput Compressor Knob Values Gain Threshold ReleaseNon-linear Transfer FunctionsUsing the 20/20 AD Lexicon Link Gain Realigning Two DAT RecordingsDigital Sinewave Generator Definition of Terms Definition of Terms Oak Park Bedford, MA 01730 USA Tel Fax