Sears 140 owner manual Troubleshooting

Page 10

TROUBLESHOOTING

PROBLEM: Low or No Output Voltage

Reason/Solution

1.Poor contact at terminals.

Unplug and reinsert Power Inverter 140.

2.Equipment being operated is drawing too much power.

Use a higher capacity inverter or do not use the device.

3.Inverter is too hot (thermal shut down).

Allow inverter to cool. Check for adequate ventila- tion. Reduced the load on the inverter to rated continuous power output.

4.Fuse blows

A blown fuse is usually caused by reverse polarity or a short circuit within the device being operated. To replace:

Disconnect the device immediately.

Find the source of the problem, and repair it.

Install a new 15-amp fuse. Do not tighten the fuse cap too far; finger tight is sufficient.

Note: Installing a fuse higher than 15-amps may cause damage to the inverter.

5.Inverter may be defective.

Call 1-800-SEARS-64 (1-800-732-7764) for trouble- shooting assistance, or return it to any Sears store or other DieHard outlet in the United States for a free replacement.

10

Image 10
Contents Power Inverter Model NoTable of contents One-Year Full Warranty on DieHard Power Inverter WarrantyImportant safety Instructions Page Power Inverter 140 Product Features Before Using Power Inverter Operating Instructions Usage Examples Power SourceDevice Type Estimate Wattage LED Indicator and Overload Protection ResetTroubleshooting Replacement Parts SpecificationsFuse 15 Amp