| Supplement_five,S1.b2 is for Supplement_mh, S1.b3 is for |
|
| Supplement_ssi. |
Supplement_two | Esc,0,4,88,m,S1,BCC | S1 is 0_off,1 on |
Supplement_five | Esc,0,4,89,m,S1,BCC | S1 is 0_off,1 on |
Supplement_mh | Esc,0,4,8a,m,S1,BCC | S1 is 0_transmit if present,1 must present |
Supplement_ssi | Esc,0,4,8b,m,S1,BCC | S1 is 0 Space been inserted, 1_Space not been inserted |
Delta_code_set | Esc,0,4,8c,m,S1,BCC | S1 is S1.b0 is for Delta_c_enable,S1.b1 is for |
|
| Delta_code_cdc,S1.b2 is for Delta_code_cds |
Delta_c_enable | Esc,0,4,8d,m,S1,BCC | S1 is 0_disable,1 enable |
Delta_code_cdc | Esc,0,4,8e,m,S1,BCC | S1 is 0_check digit calculate,1 not calculate |
Delta_code_cds | Esc,0,4,8f,m,S1,BCC | S1 is =0 check digit send,1_not send |
Get_version | Esc,0,3,90,2,BCC | Get firmware version. |
DumpSetting | Esc,Lh,Ll,91,m,S1...Si,BC | Lh/Ll is command length. Si is in the range of s1 to S255.m=0 |
| C | is download setting, m=1 is reset the setting area into FF. m=2 |
|
| is upload setting. |
|
| Actually you just need the format as bellow: |
|
| Download: |
|
| Esc,1,02,91,0,s1,...,s255,BCC |
|
| Upload: |
|
| Esc,0,3,91,2,BCC |
EAN128Brace | Esc,0,4,92,m,S1,BCC | S1 is =0_disable,1 enable(Remove the brace) |
Remove |
|
|
AimingTime | Esc,0,4,93,m,S1,BCC | S1 is =0 0.5s,1_1s,2 1.5s 3 2s |
|
|
|
|
|
|
Exchange data | Esc,Lh,Ll,a3,S1,S2,....,Sn, | • Expect Acknowledge (Esc,80H+ACK(06H)) |
| BCC | • Exchange the data between the host and the ICC. |
|
| • Expected return after issuing Execute/Enquiry command |
|
| are: Esc,Lh,Ll,0xa3,AH,data,BCC |
|
| Here: AH=0 Success |
|
| =1 Timeout |
|
| =2 No card present |
|
| data: Response data and status word |
Note: Hamster save these commands to buffer and do not execute until it receives an Execute command (Esc,ENQ). Hamster execute the command after receive an “Esc,ENQ” then send back a reply. The Max. Length of data is 264. The m and the reply define as following:
DATA TO HOST FROM HAMSTER
Data format: Code_number,Lh,Ll,string
Here: The Lh/Ll is string length, Lh is high byte, Ll is low byte, The string length is excluded the
Code_number and Lh/Ll. The string contains the Code ID, pre_amble, scanned data,post_amble, and terminator. Code_number is equal to following number plus H’80.
0 Code 39 full ASCII |
| 1 Code 39 standard or EDP Code | 2 EAN 13 | 3 UPC A | |||||||||
4 EAN 8 |
| 5 UPC E |
|
|
| 6 I25 | 7 Codabar | 8 Code 128 | 9 Code 93 | ||||
10 S25 |
| 11 MSI |
|
| 12 EAN 128 | 13 Code 32 | 14 Delta | 15 Label | |||||
16 | Plessey |
| 17 Code 11 |
|
| 18 Toshiba | 19 reserved | 20 Track 1 | 21 Track 2 | ||||
22 | Track 3 | 23 | More than 1 track |
| 24 reserved | 25 RS232 |
| 26 reserved | 27 reserved | ||||
28 reserved |
| 29 reserved |
|
| 30 reserved | 31 reserved | 32 reserved | 33 reserved |
-