Uniden BC796D, APCO 25 manual Setting the Modulation Mode, Setting Priority Channels

Page 46

6:25KHz

Use 25 kHz steps

7:50KHz

Use 50 kHz steps

8:100KHz

Use 100 kHz steps

9:AUTO

Automatically set the step size based on the band

Setting the Modulation Mode

2:SCAN OPTION → 1:CONVENTIONAL → Channel No. → 7:MODE

Radio transmissions are modulated in several different ways. The BC796D is able to demodulate the most common transmission types. Your scanner has the most common modulation mode preset for each band, so you seldom have to change this option. However there are occasional services that use a modulation mode that is not standard for that band.

1:AM

Amplitude Modulation

2:FM

Frequency Modulation

3:WFM

Wideband FM

4:NFM

Narrowband FM

Setting Priority Channels

You can set one conventional channel in each bank as a priority channel. When you turn on the Priority Scan option (see “Priority Scanning”), the scanner automatically checks these channels every 2 seconds to see if there is activity. If there is, the scanner immediately switches to the priority channel.

Notes: • The scanner does not check priority channels in locked-out banks.

The scanner does not check priority channels if the channel is locked out.

By default, the first channel of each bank is set as priority. To change the priority channel:

1.Manually select the channel you want to set as priority.

2.Press and hold PRI for 2 seconds. The scanner beeps and the new priority assignment is made.

Note: To program priority talkgroup ID’s for trunk scanning, see “Setting Priority Talkgroups.”

40

Image 46
Contents Page Page Contents Programming Trunked Systems Setting Apco 25 Sound Quality Programming LTR Systems Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Simplex Operation Understanding ScanningConventional Scanning Repeater OperationTrunked Scanning Motorola TrunkingEdacs Trunking Understanding Banks and Channels LTR TrunkingGetting More Information Front and Rear View BC796DDisplay Icons Icon DescriptionIncluded With Your Scanner Mounting an Antenna Setting Up Your ScannerConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Connecting an External Speaker Desktop InstallationApplying Power Using Standard AC Power Connecting an EarphoneListening Safely Connecting the Clone CableConnecting the Tape Recorder RememberBasic Operation Setting the SquelchTurning On the Scanner Scanning Programmed Channels Using the MenuManually Selecting a Channel Locking/Unlocking BanksPriority Scanning Locking/Unlocking ChannelsRestoring All Locked Out Channels Priority Plus ScanningTurning the Key Beep On/Off Dimmer Light SettingControlling How Much Information Appears Locking the Enter keyMuting All Audio Setting Squelch ModeDisabling the APCO25 Card Trunk Scanning OptionsSelecting Talkgroup Lists to Scan Scanning Only Stored Talkgroups ID ScanMonitoring Talkgroup ID’s Holding on a Single TalkgroupUnlocking All Talkgroups Edacs BlockoutEdacs Patch Tracking Searching Setting Chain SearchSetting Data Skip Holding on an Active FrequencyStoring Found Frequencies Automatically Storing FrequenciesSearching for Subaudible Tones Setting Subaudible Tones for SearchingSetting Delay for All Search Ranges Attenuating All Search RangesSetting a Search Range Searching for Trunk SystemsPage Service Search Service Search SkipUsing Weather Alert Same Using Weather Search and Weather Alert SameSearching for a Weather Broadcast Testing the Weather Alert Programming Bank Information Bank ConfigurationAssigning Bank Names Transferring Channel Information General ProgrammingDeleting Frequencies from Channels Entering Alpha InformationPage Enter the Frequency Programming Conventional Channels Select a Channel to Program Assigning a Text TagSetting the Delay Setting the Subaudible Tone OptionSetting the Attenuator Setting Beep AlertChanging the Frequency Step Setting the Modulation Mode Setting Priority ChannelsProgramming Trunked Systems Using I-Call Motorola and Edacs only Setting Trunking DelayTurning I-Call On and Off for ID Search Turning I-Call On for ID Scan Setting Priority Talkgroups Motorola and Edacs onlyMulti-Track Multi-Track Operational DetailsPage Programming Motorola Systems Using Control Channel ProgrammingProgramming Type 2/Digital 800 and 900 MHz Systems Programming Type2/Digital VHF and UHF Systems Programming Type I and IIi Hybrid Systems Toggling the Status Bit Toggling End Code DetectProgramming Edacs Systems Setting Edacs Emergency AlertProgramming Edacs Channels Setting Edacs Decimal Mode Setting Apco 25 Sound Quality Programming Apco 25 SystemsProgramming LTR Systems Storing Known Talkgroups Programming TalkgroupsStoring Found Talkgroups Adding a Text Tag to an ID List Deleting Stored Talkgroup ID’sSeeing Talkgroup Activity PC Control Mode Using the Remote InterfaceCloning Scanner Settings Clone Master Unit Slave Unit Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Preset Fleet Maps AppendixPreset Map Block User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsNWR-SAME Event Code SVS Severe WX Reverse List BC796D Flow Charts Beep Alert System Option Dimmer One Year Limited Warranty Uniden America CorporationMemo Memo Memo