Waves Trans-X manual

Page 7

RELEASE: 0.50 to 500ms. Default:10.02ms.

This is the release time for the gain adjustment. Once the detected transient is over, this is the time it will take the gain adjustment to settle back to 0dB. The release is actually not completely linear and in the multiband it is even scaled differently for each band.

OUTPUT: +18dB to –18dB. Default: 0dB.

The Output fader is located between the output meters and adjusts the gain of the overall output of the Trans-X.

TRIM: Click to Trim.

The Trim control is located between the clip indicators and shows the number that is the difference between the peak energy and the full digital scale or 0.0dBfs. When you click the Trim control, it will adjust the output gain by the indicated value. For example, if the Trim box indicates 3.2dB below full scale, then clicking it will increase the current output gain by 3.2dB. This is convenient for setting the best level for the plug-in output without clipping it.

Multiband Only: Per band ON/OFF: Default: On.

This will turn the Transient processing on and off for the related band.

Waves Trans-X software guide page 7 of 8

Image 7
Contents Waves Trans-X Software Audio Processor User’s Guide Introduction and Overview Page Using the Trans-X Multiband Considerations Controls and displays Page TRANS-X Displays