Intel Evaluation Board Set-Up, LXD381 Packing List, Equipment Requirements, Power Connections

Page 7

Evaluation Board for Octal E1 Applications — LXD381

2.0Evaluation Board Set-Up

Caution: CMOS devices are static (ESD) sensitive. Take all industry standard precautions when handling the evaluation board, the LXT381 chip and other sensitive electronic components.

Before proceeding with any evaluation board operations, review the specifications for the LXT381 transceiver.

2.1LXD381 Packing List

The evaluation board kit contains the following components:

LXD381 board with LXT381 device installed.

LXD381 User Guide.

LXT381 Data Sheet.

2.2Equipment Requirements

The evaluation board kit includes all the circuit components needed for a successful evaluation. However, the following lab equipment is required:

Power Supply (+3.3 VDC).

Telecom cable or cable simulator (optional).

E1 pattern generator/analyzer

2.3Power Connections

The evaluation board has two power planes (VCC and TVCC) each of which is tied to a separate red colored banana jack. Connect the +3.3 VDC power supply to both the VCC (B1) and TVCC (B3) banana jacks. Connect the power supply ground lead to the black banana jack (B2).

2.4Loopback Mode Selection

The LXT381 LOOP signals for channels 0 through 7 are set by the switches in switch block S1. As shown in Table 1, these switches have three positions to select Remote Loopback, Analog Loopback or No Loopback.

Table 1. LOOP0 - 7 Switch Settings

S1 Switch Position

Operation

 

 

High

Analog Loopback

 

 

Center

No Loopback

 

 

Low

Remote Loopback

 

 

Developer Manual

7

Image 7
Contents Developer Manual LXD381 Evaluation Board for Octal E1 ApplicationsPage Contents Page General Description FeaturesLXD381 Evaluation Board for Octal E1 Applications LXD381 Packing List Power ConnectionsLoopback Mode Selection Evaluation Board Set-UpBack-End Interface Connection Output Enable SelectionUnused Switches Receive Polarity SelectionLine Interface Circuit Line Interface ConnectionBoard Protection Manual Digital I/O LXD381 For