CONNECTIONS

The connections described below should be made by qualified service personnel or system installers.

An example of a basic connection is shown below.

Video Switcher

VIDEOA

IN

CCIR EIA

OUT

AC IN

Connection with the Camera

Site

Connect the Video output of the camera site equipment to the VIDEO IN connector at the rear of the monitor using a coaxial cable.

The maximum coaxial cable length between the camera and the monitor is shown in the table below.

Cable

RG-59/U

RG-6/U

RG-11/U

RG-15/U

3C-2V

5C-2V

7C-2V

10C-2V

 

 

 

 

 

 

Cable length

500 m

750 m

1 000 m

1 250 m

(1 650 ft)

(2 475 ft)

(3 300 ft)

(4 125 ft)

 

 

 

 

 

 

Multiple Monitor Connection

Connect the VIDEO OUT connector on the monitor to the VIDEO IN connector of an other monitor with a coaxial cable to monitor the same video on multiple monitors.

Up to 10 monitors in total can be connected in a series before signal loss occurs. The total cable length should not exceed 150 m (500 feet).