Panasonic WV-BM1790 operating instructions Connections, Connection with the Camera Site

Page 6

CONNECTIONS

The connections described below should be made by qualified service personnel or system installers.

An example of a basic connection is shown below.

Video Switcher

VIDEOA

IN

CCIR EIA

OUT

AC IN

■Connection with the Camera

Site

Connect the Video output of the camera site equipment to the VIDEO IN connector at the rear of the monitor using a coaxial cable.

The maximum coaxial cable length between the camera and the monitor is shown in the table below.

Cable

RG-59/U

RG-6/U

RG-11/U

RG-15/U

3C-2V

5C-2V

7C-2V

10C-2V

 

 

 

 

 

 

Cable length

500 m

750 m

1 000 m

1 250 m

(1 650 ft)

(2 475 ft)

(3 300 ft)

(4 125 ft)

 

 

 

 

 

 

■Multiple Monitor Connection

Connect the VIDEO OUT connector on the monitor to the VIDEO IN connector of an other monitor with a coaxial cable to monitor the same video on multiple monitors.

Up to 10 monitors in total can be connected in a series before signal loss occurs. The total cable length should not exceed 150 m (500 feet).

Video Switcher

Cameras

Coaxial

Cable

Coaxial Cable

VIDEO

IN

First Video

Monitor

OUT

VIDEO

IN

Last Video

Monitor

OUT

6

Image 6