Panasonic CR Relays specifications Features, Specifications, Typical Applications

Page 1

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWIN POWER SILENT

CR RELAYS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTOMOTIVE RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24.6

17.0

.969

.669

18.5

.728

mm inch

RoHS Directive compatibility information

http://www.nais-e.com/

FEATURES

• Silent

board layout

Noise has been reduced by

 

 

approximately 20 dB, using our own

 

 

silencing design.

 

 

• Twin (1 Form C 2)

Coil

 

Forward/reverse motor control is possible

 

 

 

with a single relay.

Normally

 

• Sealed construction

Open

• Simple footprint enable ease of PC

 

 

Common

Coil

Normally

Closed

SPECIFICATIONS

Contact

Arrangement

 

 

1 Form C 2

 

 

 

 

Contact material

 

 

Ag alloy (Cadmium free)

 

 

Initial contact resistance (Initial)

Typ. 6 m(N.O.)

(By voltage drop 6 V DC 1A)

Typ. 9 m(N.C.)

 

 

Contact voltage drop

Max. 0.2V (at 10 A)

 

 

 

 

 

Nominal switching

N.O.: 20 A 14 V DC

 

capacity

N.C.: 10 A 14 V DC

 

 

 

 

 

 

 

35 A for 2 minutes,

 

 

 

25 A for 1 hour

Rating

Max. carrying current

(12 V, at 20°C68°F)

 

30 A for 2 minutes,

 

 

 

 

 

 

20 A for 1 hour

 

 

 

(12 V, at 85°C185°F)

 

 

 

 

Min. switching capacity#1

1 A 12 V DC

 

 

 

 

Mechanical (at 120 cpm)

Min. 107

 

 

 

 

Expected life

 

Resistive load

Min. 105*1

(min. operations)

Electrical

Motor load

Min. 2105*2

 

 

 

 

 

Min. 105*3

 

 

 

 

 

 

 

Coil

Nominal operating power

640 mW

 

 

#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.

Remarks

*1

At nominal switching capacity, operating frequency: 1s ON, 9s OFF

*2

N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating

 

frequency: 0.5s ON, 9.5s OFF

*3

At 20A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF

*4

Measurement at same location as “Initial breakdown voltage” section

*5

Detection current: 10mA

*6

Excluding contact bounce time

*7

Half-wave pulse of sine wave: 11ms; detection: 10s

*8

Half-wave pulse of sine wave: 6ms

*9

Detection time: 10s

Characteristics

Max. operating speed

 

6 cpm

(at nominal switching capacity)

 

 

 

 

Initial insulation resistance*4

Min. 100 M(at 500 V DC)

 

 

 

 

 

 

 

 

 

 

Between open

500 Vrms for 1 min.

Initial breakdown

 

contacts

 

 

voltage*5

 

 

 

Between contacts

500 Vrms for 1 min.

 

 

 

 

and coil

 

 

 

 

 

 

 

 

 

 

Operate time*6

 

Max. 10 ms (initial)

(at nominal voltage)(at 20°C68°F)

 

 

 

 

 

Release time*6

 

Max. 10 ms (initial)

(at nominal voltage)(at 20°C68°F)

 

 

 

 

 

 

 

Shock resistance

 

Functional*7

Min. 100 m/s2 {10G}

 

 

 

 

Destructive*8

Min. 1,000 m/s2 {100G}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Functional*9

10 Hz to 100 Hz,

 

 

 

 

Min. 44.1 m/s2 {4.5G}

Vibration resistance

 

 

 

 

 

 

Destructive*10

10 Hz to 500 Hz,

 

 

 

 

 

 

 

 

Min. 44.1 m/s2 {4.5G}

 

 

 

 

 

 

 

 

 

 

Conditions for

 

Ambient

–40°C to +85°C

operation, transport

 

 

temperature

–40°F to +185°F

and storage*11

 

 

 

 

(Not freezing and

 

 

 

condensing at low

 

Humidity

5% R.H. to 85% R.H.

temperature)

 

 

 

Mass

 

 

 

 

Approx. 12.5g.44 oz

 

 

 

*10 Time of vibration for each direction;

 

X

Y X, Y, direction: 2 hours

 

 

 

Z direction: 4 hours

 

 

 

Z

 

 

*11 Refer to Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.

Please inquire if you will be using the relay in a high temperature atmosphere (110°C 230°F).

TYPICAL APPLICATIONS

Power windows

Auto door lock

Electrically powered sunroof

Electrically powered mirror, etc.

ORDERING INFORMATION

Ex. CR

2

 

12 V

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact arrangement

 

Coil voltage(DC)

 

 

 

 

 

 

 

 

 

 

1 Form C 2

 

 

12 V

 

 

 

 

 

 

 

 

 

 

Standard packing: Carton(tube package) 32pcs. Case: 800pcs.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Image 1
Contents Specifications FeaturesTypical Applications Ordering InformationExample of Circuit Dimensions±.004 To 3mm .039 to .118 inch ±0.2 ±.008Reference Data Circuit Electrical life test Motor freeLoad current waveform Change of pick-up and drop-out voltage