52 | FAN ERROR 5 | LAMP4 FAN | Normal fan operation |
51 | FAN ERROR 4 | LAMP3 FAN |
|
50 | FAN ERROR 3 | LAMP2 FAN |
|
49 | FAN ERROR 2 | LAMP1 FAN |
|
48 | FAN ERROR 1 |
| |
47 | — |
|
|
46 | — |
|
|
45 | — |
|
|
|
|
|
|
44 | — |
|
|
|
|
|
|
43 | — |
|
|
42 | — |
|
|
41 | — |
|
|
|
|
|
|
40 | — |
|
|
|
|
|
|
39 | — |
|
|
38 | — |
|
|
37 | CHANGE INTERNAL CLOCK BATTERY | Date/time is invalid (before Jan. 1, 2006 or Jan. 1, 2036 or later). | Date/time reset (after battery change) |
|
|
|
|
36 | FILTER CLOGGED ERROR |
|
|
35 | AIR VOLUME SENSOR NOT FOUND | The air volume sensor is not found. | Main power on |
34 | OUTPUT AIR SENSOR NOT FOUND | The output air sensor is not found. |
|
33 | DMD SENSOR NOT FOUND | The DMD sensor is not found. |
|
|
|
|
|
32 | INPUT AIR SENSOR NOT FOUND | The input air sensor is not found. |
|
29 | LAMP COVER NOT CLOSED | The lamp cover is not closed (for more than 1 second continuously). | Lamp cover closed, then main power on |
28 | AC VOLTAGE DROP WARNING (BELOW 90 V) |
|
|
|
|
|
|
27 | LAMP 4 NOT MOUNTED | The lamp is not mounted. | Lamp mounted, then main power on |
|
|
|
|
26 | LAMP 3 NOT MOUNTED |
|
|
25 | LAMP 2 NOT MOUNTED |
|
|
24 | LAMP 1 NOT MOUNTED |
|
|
|
|
|
|
23 | LAMP 4 IGNITIONFAILURE | The lamp fails to ignite. | Lamp illumination processing performed |
|
|
|
|
22 | LAMP 3 IGNITIONFAILURE |
|
|
21 | LAMP 2 IGNITIONFAILURE |
|
|
20 | LAMP 1 IGNITIONFAILURE |
|
|
|
|
|
|
19 | LAMP 4 ILLUMINATION FAILURE | The lamp fails to illuminate. |
|
|
|
|
|
18 | LAMP 3 ILLUMINATION FAILURE |
|
|
17 | LAMP 2 ILLUMINATION FAILURE |
|
|
16 | LAMP 1 ILLUMINATION FAILURE |
|
|
|
|
|
|
15 | LAMP 4 USAGE TIME ELAPSED | The lamp usage time exceeds the stipulated value | Lamp replaced |
|
|
|
|
14 | LAMP 3 USAGE TIME ELAPSED |
|
|
13 | LAMP 2 USAGE TIME ELAPSED |
|
|
|
|
|
|
12 | LAMP 1 USAGE TIME ELAPSED |
|
|
|
|
|
|
11 | LAMP 4 USAGE TIME WARNING | The lamp usage time exceeds the stipulated value. |
|
|
|
|
|
10 | LAMP 3 USAGE TIME WARNING |
|
|
9 | LAMP 2 USAGE TIME WARNING |
|
|
|
|
|
|
8 | LAMP 1 USAGE TIME WARNING |
|
|
|
|
|
|
7 | DMD LOW TEMP. ERROR | The DMD ambient temperature is lower than the stipulated value. | DMD ambient temperature at or above stipulated value |
|
|
|
|
6 | OUTPUT AIR TEMP. ERROR | The output air temperature exceeds the stipulated value. | Output air temperature below stipulated value |
5 | DMD TEMP. ERROR | The DMD ambient temperature exceeds the stipulated value. | DMD ambient temperature below stipulated value |
|
|
|
|
4 | INPUT AIR ERROR | The input air temperature exceeds the stipulated value. | Input air temperature below stipulated value |
|
|
|
|
3 | DMD LOW TEMP. WARNING | The DMD ambient temperature is lower than the stipulated value. | DMD ambient temperature at or above stipulated value |
|
|
|
|
2 | OUTPUT AIR TEMP. WARNING | The output air temperature exceeds the stipulated value. | Output air temperature below stipulated value |
1 | DMD TEMP. WARNING | The DMD ambient temperature exceeds the stipulated value. | DMD ambient temperature below stipulated value |
|
|
|
|
0 | INPUT AIR TEMP. WARNING | The input air temperature exceeds the stipulated value. | Input air temperature below stipulated value |
|
|
|
|
Note |
|
|
|
* Make sure to specify option FEh for this unit.
11