Panasonic PT-D3500 FAN Error LAMP4 FAN, Filter Clogged Error AIR Volume Sensor not Found

Page 11

52

FAN ERROR 5

LAMP4 FAN

Normal fan operation

51

FAN ERROR 4

LAMP3 FAN

 

50

FAN ERROR 3

LAMP2 FAN

 

49

FAN ERROR 2

LAMP1 FAN

 

48

FAN ERROR 1

P-UNIT FAN

 

47

 

 

46

 

 

45

 

 

 

 

 

 

44

 

 

 

 

 

 

43

 

 

42

 

 

41

 

 

 

 

 

 

40

 

 

 

 

 

 

39

 

 

38

 

 

37

CHANGE INTERNAL CLOCK BATTERY

Date/time is invalid (before Jan. 1, 2006 or Jan. 1, 2036 or later).

Date/time reset (after battery change)

 

 

 

 

36

FILTER CLOGGED ERROR

 

 

35

AIR VOLUME SENSOR NOT FOUND

The air volume sensor is not found.

Main power on

34

OUTPUT AIR SENSOR NOT FOUND

The output air sensor is not found.

 

33

DMD SENSOR NOT FOUND

The DMD sensor is not found.

 

 

 

 

 

32

INPUT AIR SENSOR NOT FOUND

The input air sensor is not found.

 

29

LAMP COVER NOT CLOSED

The lamp cover is not closed (for more than 1 second continuously).

Lamp cover closed, then main power on

28

AC VOLTAGE DROP WARNING (BELOW 90 V)

 

 

 

 

 

 

27

LAMP 4 NOT MOUNTED

The lamp is not mounted.

Lamp mounted, then main power on

 

 

 

 

26

LAMP 3 NOT MOUNTED

 

 

25

LAMP 2 NOT MOUNTED

 

 

24

LAMP 1 NOT MOUNTED

 

 

 

 

 

 

23

LAMP 4 IGNITIONFAILURE

The lamp fails to ignite.

Lamp illumination processing performed

 

 

 

 

22

LAMP 3 IGNITIONFAILURE

 

 

21

LAMP 2 IGNITIONFAILURE

 

 

20

LAMP 1 IGNITIONFAILURE

 

 

 

 

 

 

19

LAMP 4 ILLUMINATION FAILURE

The lamp fails to illuminate.

 

 

 

 

 

18

LAMP 3 ILLUMINATION FAILURE

 

 

17

LAMP 2 ILLUMINATION FAILURE

 

 

16

LAMP 1 ILLUMINATION FAILURE

 

 

 

 

 

 

15

LAMP 4 USAGE TIME ELAPSED

The lamp usage time exceeds the stipulated value

Lamp replaced

 

 

 

 

14

LAMP 3 USAGE TIME ELAPSED

 

 

13

LAMP 2 USAGE TIME ELAPSED

 

 

 

 

 

 

12

LAMP 1 USAGE TIME ELAPSED

 

 

 

 

 

 

11

LAMP 4 USAGE TIME WARNING

The lamp usage time exceeds the stipulated value.

 

 

 

 

 

10

LAMP 3 USAGE TIME WARNING

 

 

9

LAMP 2 USAGE TIME WARNING

 

 

 

 

 

 

8

LAMP 1 USAGE TIME WARNING

 

 

 

 

 

 

7

DMD LOW TEMP. ERROR

The DMD ambient temperature is lower than the stipulated value.

DMD ambient temperature at or above stipulated value

 

 

 

 

6

OUTPUT AIR TEMP. ERROR

The output air temperature exceeds the stipulated value.

Output air temperature below stipulated value

5

DMD TEMP. ERROR

The DMD ambient temperature exceeds the stipulated value.

DMD ambient temperature below stipulated value

 

 

 

 

4

INPUT AIR ERROR

The input air temperature exceeds the stipulated value.

Input air temperature below stipulated value

 

 

 

 

3

DMD LOW TEMP. WARNING

The DMD ambient temperature is lower than the stipulated value.

DMD ambient temperature at or above stipulated value

 

 

 

 

2

OUTPUT AIR TEMP. WARNING

The output air temperature exceeds the stipulated value.

Output air temperature below stipulated value

1

DMD TEMP. WARNING

The DMD ambient temperature exceeds the stipulated value.

DMD ambient temperature below stipulated value

 

 

 

 

0

INPUT AIR TEMP. WARNING

The input air temperature exceeds the stipulated value.

Input air temperature below stipulated value

 

 

 

 

Note

 

 

 

* Make sure to specify option FEh for this unit.

11

Image 11
Contents Basic format Pin assignments and signal namesCommunication conditions Factory setting D3500 Remarks Control commandsAdjustment Mode CommandParameter Function Call BackD3500 Meaning Remarks Status Asking CommanReserved VPS System QVY Single Lamp Power QLPMute on Volume QAV YESFor example Extended format for lensStart Parameter End 0x02Responses from the projector Cable specificationsTransmission from the computer D5500 D3500 Bit allocation for Self-diagnosis informationBit Title Description Example Bits Bit127Resize Setting Error FM Communication ErrorFPGA2 Setting Error FPGA1 Setting ErrorDMD TEMP. Error FAN Error LAMP4 FANFilter Clogged Error AIR Volume Sensor not Found Output AIR TEMP. ErrorExample