CR 106129: ATM

The router incorrectly determines specific 802.5 MAC addresses as broadcasts when processing LE_ARP responses. This causes the LEC to restart.

CR 107143: ATM

The router is not responding to LE_ARP destined for it's own MAC address on

802.5elans. This condition affects performance because the router sends unnecessary traffic to other LECs and creates congestion on the bus.

CR 107164: Frame relay

Bus errors occur on the FRE processor before it goes into diag mode when you bring down a frame relay interface with an HSSI card configured with IP. This occurs whenever the router brings down the frame relay interface after not receiving the LMI status messages.

CR 107581: BGP

BGP is not advertising and withdrawing correctly when handling two announcements of the same network to two different peers.

CR 107675: DVMRP

When a non-dominant router becomes the dominant router and subordinate routers are contained in its loop neighbor list, the newly dominant router will not graft traffic.

CR 107703: IGMP

Multicast data packets gets duplicated on a DVMRP router where MTM has outbound cache entry on an inbound circuit.

CR 107811: ATM

A memory leak occurs on the ATM interface after a virtual circuit is repeatedly brought up and then killed using the Technician Interface.

CR 107938: ATM

The router does not clean up the ATM circuit when a port is dynamically deleted using Site Manager.

305279-C Rev 00

1-11

Image 19
Contents Page Copyright 1999 Nortel Networks Nortel Networks NA Inc. Software License Agreement Rev Contents Page Hard-Copy Technical Manuals PrefaceHow to Get Help Maintenance Release Methodology Site Manager Compatibility Year 2000 Compliance BayRS Version 13.03 Fixed AnomaliesCR 30952 DLSw Rev Rev Rev Rev Rev Rev Rev Rev Rev Site Manager Software Version 7.03 Fixed Anomalies Rev Rev Rev