Nortel Networks 8600 manual EMI Warnings

Page 4

Important Regulatory Information

EMI Warnings

!WARNING:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.

!WARNING:

To Users of Digital Apparatus in Canada:

This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada.

Notice to Users of the Canadian Telephone Network

The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user's satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.

Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

CAUTION:

Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.

C

October 1997

8600-A2-GN20-20

Image 4
Contents Installation Guide Copyright  1997 Paradyne Corporation All rights reserved Warranty, Sales, and Service InformationTrademarks Important Safety Instructions EMI Warnings CE Marking JapanContents Initial Setup Instructions Document Purpose and Intended Audience About This GuideIii Document Summary Section DescriptionProduct-Related Documents Document Number Document TitleAbout the HotWire 8600 Dslam What is the HotWire 8600 DSLAM?Network Service Provider HotWire 8600 Dslam Components InputHotWire 8600 Dslam Features Power RedundancyMounting Configurations 97-15355 Installing and Connecting Hardware OverviewPackage Contents Unpacking the HardwarePre-installation Considerations Installation SiteInstallation Tasks Task SeeProcedure HotWire 8600 Dslam Chassis InstallationStacking the 8600 Chassis Stack Position Connection to the CO Ground Lug National Equipment Building Standards NebsESD Wrist Strip Jack Interconnecting 8600 Systems DSL Inch Rack Front Rail Front Rail Speed Nut Using a Single DC Power Source Supplying PowerInsert Power Source As Into Using Two DC Power Sources for Power Redundancy Insert Power Source Into Using Only AC Power Source Using AC Power with DC Power BackupInsert Power Source Bs Into Installing the MCC Card Handling Precautions for STATIC-SENSITIVE DevicesInstalling DSL Cards October Verifying the Installation Making Cable Connections Special Connection ConsiderationsConnecting to a Pots Splitter or an MDF T5AConnecting the DSL Cards to the Ethernet Hubs or Switches InputConnecting to an Snmp Management System Connecting to a Terminal or Laptop Computer Connecting to a Modem for Remote Management Connecting to a HotWire 8600 Dslam Via Telnet Initial Setup Instructions Initial Setup Instructions 8600-A2-GN20-20 October Power Failure Troubleshooting Procedures TroubleshootingPower LED is OFF System ALM LED is on on a DSL Card Fan Alarm LED is onDSL Card is Not Working Properly LEDs HotWire 8600 Dslam ChassisLED is Indicating MCC Card TypePinouts Pin Number UsePin Modular LAN/WAN Slot Connector Pinouts Pin Modular Management In and Out Connector PinoutsPin Modular Serial Asynchronous Terminal Connector Pinouts DB25 Adapter PinoutsPin Number Function Pin Modular DB25 Serial Interface Use Pin NumberDSL Slot, Port # Tip, Ring Technical Specifications Specifications CriteriaTechnical Specifications Glossary GL-1GL-2 Index IN-1IN-2 IndexIN-3
Related manuals
Manual 41 pages 17.31 Kb Manual 136 pages 14.91 Kb Manual 44 pages 49.61 Kb Manual 88 pages 41.11 Kb

8600 specifications

Nortel Networks 8600 is a highly regarded member of the Nortel Ethernet routing portfolio, specifically designed to meet the demands of today's bandwidth-hungry environments. This advanced platform is a favorite for service providers and enterprises due to its scalability, reliability, and performance capabilities.

One of the standout features of the Nortel 8600 is its exceptional scalability. The platform supports a wide range of Ethernet services that can accommodate the growth of network applications without requiring significant overhaul. This scalability is driven by its ability to provide multiple 10 Gigabit and 100 Gigabit Ethernet ports, allowing organizations to expand their network as bandwidth needs increase.

The 8600 employs a robust architecture that enhances its performance. It utilizes a switching fabric that delivers high throughput and low latency, making it ideal for applications that demand real-time data transmission, such as voice over IP (VoIP) and video streaming. With support for high-density Ethernet, the 8600 can handle a large number of simultaneous connections, facilitating seamless experiences for end-users.

Another technological highlight of the Nortel 8600 is its integrated service capabilities. The platform incorporates advanced quality of service (QoS) features that prioritize bandwidth for critical applications, ensuring reliable performance even during peak usage times. The 8600 also supports comprehensive security protocols, providing peace of mind for organizations as they navigate the complexities of modern cybersecurity challenges.

Additionally, the platform offers advanced management features that simplify network administration. Built-in tools for monitoring and reporting enhance operational visibility, enabling IT teams to quickly identify and resolve issues. The 8600 is designed to integrate smoothly with existing networking environments, offering interoperability with multiple vendors and protocols, thus protecting investment in other technologies.

Energy efficiency is another characteristic of the Nortel 8600, making it a suitable choice for organizations keen on reducing operational costs and minimizing their environmental impact. The platform is built with energy-saving components and intelligent power management that allow businesses to operate sustainably.

Overall, the Nortel Networks 8600 is a sophisticated routing solution that integrates cutting-edge technologies to meet the demands of modern network environments, making it a preferred choice for organizations seeking a balance between performance, reliability, and cost-effectiveness.