Nortel Networks 8600 manual Variable definitions

Page 48

48Initial steps using the CLI

7Save the boot configuration.

8Reboot the switch.

--End--

Variable definitions

Use the data in the following table to use the config bootconfig sio command.

Variable

Value

 

 

8databits <truefalse>

Specifies either 8 (true) or 7 (false)

 

data bits for each byte for software to

 

interpret. The default is false.

 

 

baud <rate>

Configures the baud rate for the port.

 

The default is 9600.

 

 

enable <truefalse>

Enables or disables the port. The

 

default is true.

 

 

info

Displays information about the

 

specified port.

 

 

mode <asciislipppp>

Configures the communication

 

mode for the serial port. The default

 

is American Standard Code for

 

Information Interchange (ASCII).

 

If you are configuring the modem

 

port, you can configure the

 

port to use the SLIP or the PPP

 

communication mode.

 

 

mtu <bytes>

Configures the size of the maximum

 

transmission unit for a PPP link

 

(0–2048). The default is zero.

 

 

my-ip <ipaddr>

Configures the IP address for the

 

server side, the Nortel Ethernet

 

Routing Switch 8600, of the

 

point-to-point link. The default is

 

0.0.0.0. Nortel recommends that you

 

use the current IP address for the

 

management port.

 

 

Nortel Ethernet Routing Switch 8600

Commissioning

NN46205-319 01.01 Standard

30 May 2008

Copyright © 2008 Nortel Networks

Image 48
Contents Commissioning Legal Notice Contents Initial steps using the Nncli Common procedures using Device Manager 127 Copyright 2008 Nortel Networks Software license Nortel Networks Inc. software license agreementGeneral Nortel Networks Inc. software license agreement Software license Features New in this releaseOther changes Document changesNew in this release Introduction NavigationIntroduction Commissioning fundamentals System connectionsTerminal connection Modem connectionPPP modem connection Data terminal Ready DTR Ground GND Data set readyRequest to send Clear to sendPPP configuration topology System logon Hsecure mode Default passwords and community stringsSetup utility Aging enforcementFiltering mechanism PrivateonlyCommissioning fundamentals Setup utility example one Setup utility example two Secure and nonsecure protocols Password encryption FTP and Tftp DisabledManagement port Static IP entry for the OOB network management interface OOB network management port default IP flowchart Web management Device ManagerCommissioning fundamentals Commissioning Commissioning tasksCommissioning navigation Initial steps using Device Manager Initial commissioning proceduresEditing system information Initial commissioning navigationVariable definitions SaveBootConfig-saves the current Boot configurationSaveRuntimeConfig-saves the current Run-time configurationSaveSlaveBootConfig-saves Current boot configuration toFile to enable features Configuring the date and timeChanging passwords Use the data in the following table to configure the CLI tab Variable Value Initial steps using the CLI Prerequisites to initial stepsInitial steps using the CLI Job aid Roadmap of initial CLI commands Initial steps using the CLI Connecting a terminal Connecting a modem Procedure stepsPrerequisites Baud rate 8databits truefalse mode asciislipppp Slip-compression truefalse slip-rx-compression truefalseMtu bytes my-ip ipaddr peer-ip ipaddr pppfile file Variable definitions Procedure job aid PPP file Slip-rx-compressionTruefalse Defaultroute Ipcpmaxconfigure valueAsyncmap value Chapfile fileLcpmaxconfigure value LoginIpcpmaxfailure value Ipcpmaxterminate valuePappasswd password Mtu valueNetmask value NoaccPaprestart value Papusername namePassivemode ProxyarpConfiguring the switch with the setup utility Procedure job aid setup utility promptsChapfile mychap Papfile mypap Configuring the switch with the setup utility Initial steps using the CLI FTP Initial steps using the CLI Vlan Configuring system identification Enabledisable Mgmt-virtual-ip ipaddr/mask SendAuthenticationTrapSmlt-on-single-cp enabledisa Ble timer value Enabledisable EnablesConfiguring the time zone Dst-endMm.n.d/hhmmMMddhhmm Configuring the date Dst-start Mm.n.d/hhmmMMdDhhmm Config bootconfig master cpu-slot Specifying the primary SF/CPUCpu-slot Access-level access level Access level is an integerEnabledisable enables or Logon or password Password is the passwordLogon and/or password applies Routing SwitchConfigures the minimum length For passwords in high-secureConfigures the operator logon to Previous passwords the switchResetting passwords Initial steps using the Nncli Initial steps using the Nncli Job aid Roadmap of initial Nncli commands Clock set MMddyyyyhhmmss Install Show boot config masterBoot config master cpu-slot Commissioning Log enablemaxfilesize CommunityForce GroupBoot config sio modem 8databitsbaud rate mode asciislipppp Boot config sio modem slip-compression slip-rx-comp ression Boot config sio modem restartConfigures the communication mode for Serial port. The default is American StandardIf you are configuring the modem port, you can Configure the port to use either the Slip orEnables or disables Transmission Control For Slip mode. The default is false. UseNo operator to remove this configuration. To Enables or disables TCP/IP header compressionDefaultroute Lcpmaxterminate value Novjccomp You must log on to the Privileged Exec mode in the Nncli Procedure job aid setup utility prompts Configuring the switch with the setup utility Initial steps using the Nncli FTP Initial steps using the Nncli Enables agent conformance mode Agent-conformanceAuthentication-trap BootstrapForce-iphdr-sender Force-trap-senderExample of configuring system identification To configure this option to the default Value, use the default operator withConfigures the starting date of DST Dst-end Mm.n.d/hhmmMMddhGreenwich. To configure this option to Default value, use the default operatorWith the command Clock set MMddyyyyhhmmssChanging passwords Access level word Changes the default lockout time after Three invalid attempts. ConfiguresConfigures the minimum length for Passwords in high-secure modeRemote connection configuration using Device Manager Remote connection configuration proceduresRemote connection configuration navigation Assigning an IP address to the management port Assigning static routes to the management interfaceVariable definitions Configuring Snmp settings for Device Manager access Variable definitions Click System Flags Select the EnableWebServer box Enabling the Web management interfaceRemote connection configuration using Device Manager Remote connection configuration using the CLI Remote connection configuration using the CLI Job aid Roadmap of remote connection CLI commands Config bootconfig net mgmt ip ipaddr/mask cpu-slot value Config sys set mgmt-virtual-ip ipaddr/maskConfig bootconfig net mgmt route add netaddr/mask gateway GatewayNetaddr/mask Enabling remote access services Config bootconfig net mgmt route add 11.0.0.0/255.0.0.0Config bootconfig flags access-service truefalse Flags access-service truefalse Access-serviceConfiguring the remote host logon Ftp-debugTftp-timeout Tftp-debugTftp-hash Tftp-rexmitRemote connection configuration using the CLI Remote connection configuration using the Nncli Remote connection configuration using the Nncli Job aid Roadmap of remote connection Nncli commands MaskAsk gateway Sys mgmt-virtual-ip ipaddr/mask Boot config net mgmt ip ipaddr mask value Web-serverBoot config net mgmt route netaddr/mask gateway Ipaddr maskEnabling remote access services Remote-access service types to Configuration. To configure this optionSpecifies one of the following Use the no operator to remove thisDef-display-rows Help-tftpManagement console screen. The default is disabled Use the no operator to later remove this configurationTftp-timeout Commissioning verification Commissioning verification navigationPinging an IP device Count valueUsing Telnet to log on to the device Accessing the switch through the Web interfaceAccessing the switch through the Web interface Commissioning verification Common procedures using Device Manager Common procedure navigationSaving the configuration Common procedures using Device Manager Common procedures using the CLI BackupMode clinncli FileSavetype StandbyCommon procedures using the Nncli Backup word File wordStandby word Index Time zone commands Page Commissioning
Related manuals
Manual 62 pages 39.02 Kb Manual 41 pages 17.31 Kb Manual 44 pages 49.61 Kb Manual 88 pages 41.11 Kb

8600 specifications

Nortel Networks 8600 is a highly regarded member of the Nortel Ethernet routing portfolio, specifically designed to meet the demands of today's bandwidth-hungry environments. This advanced platform is a favorite for service providers and enterprises due to its scalability, reliability, and performance capabilities.

One of the standout features of the Nortel 8600 is its exceptional scalability. The platform supports a wide range of Ethernet services that can accommodate the growth of network applications without requiring significant overhaul. This scalability is driven by its ability to provide multiple 10 Gigabit and 100 Gigabit Ethernet ports, allowing organizations to expand their network as bandwidth needs increase.

The 8600 employs a robust architecture that enhances its performance. It utilizes a switching fabric that delivers high throughput and low latency, making it ideal for applications that demand real-time data transmission, such as voice over IP (VoIP) and video streaming. With support for high-density Ethernet, the 8600 can handle a large number of simultaneous connections, facilitating seamless experiences for end-users.

Another technological highlight of the Nortel 8600 is its integrated service capabilities. The platform incorporates advanced quality of service (QoS) features that prioritize bandwidth for critical applications, ensuring reliable performance even during peak usage times. The 8600 also supports comprehensive security protocols, providing peace of mind for organizations as they navigate the complexities of modern cybersecurity challenges.

Additionally, the platform offers advanced management features that simplify network administration. Built-in tools for monitoring and reporting enhance operational visibility, enabling IT teams to quickly identify and resolve issues. The 8600 is designed to integrate smoothly with existing networking environments, offering interoperability with multiple vendors and protocols, thus protecting investment in other technologies.

Energy efficiency is another characteristic of the Nortel 8600, making it a suitable choice for organizations keen on reducing operational costs and minimizing their environmental impact. The platform is built with energy-saving components and intelligent power management that allow businesses to operate sustainably.

Overall, the Nortel Networks 8600 is a sophisticated routing solution that integrates cutting-edge technologies to meet the demands of modern network environments, making it a preferred choice for organizations seeking a balance between performance, reliability, and cost-effectiveness.