Panamax MAX 5510 owner manual Feature Overview, Pushbutton

Page 6

FEATURE OVERVIEW

Switched

Lamp

Lamp and Meter

LED Indicators:

Outlets

Receptacle:

Dimmer:

Status indicator lights

Pushbutton:

For the 5W-halogen

Controls brightness

for Switched Outlets,

1 of 2 Triggers that

Convenience Lamp.

of the Ammeter,

DC Voltage Triggers,

can activate a turn-

Use to illuminate

Voltmeter

and Unsafe Voltage

on or shutdown

working area &

backlighting and

 

 

sequence for the

other components.

Convenience Lamp.

 

 

Isolated and High-

 

 

 

 

Current outlets.

 

 

 

 

 

 

 

 

 

AC Regeneration

Control and LED

Indicators:

Select either Isolated or Balanced power for your digital source components.

Ammeter:

Backlit analog meter measures current draw for connected equipment up to 15 Amps.

Voltmeter:

Backlit analog meter measures incoming voltage source from 0-150 VAC.

Convenience Outlet: Provides a quick convenient way to plug in components such as camcorders and video game systems.

15A Circuit Breaker: Opens in the event that equipment plugged into the MAX® 5510 draws too much current. When white is visible, the breaker has opened. Reduce the load and push to reset.

Filtered Outlet Bank 1: Two Always-On, Balanced, Double L filtered outlets for Low-Current analog components such

as pre-amplifiers, receivers, VCRs and tape decks.

Isolation Transformer Outlets:

Four outlets provide either Isolated or Balanced power for digital source components such as DVD or CD players. Use the front panel AC Regeneration pushbutton to select the desired power mode.

High-Current Outlet Bank: Two delayed outlets designed for High-Current components such as amplifiers and powered subwoofers.

The current available to connected equipment is not limited by the noise filtration components.

AV RCA Jacks: Four pair of RCA style connectors. Circuits are optimized for audio and video signal line protection.

Rear Panel

Convenience Lamp

Receptacle:

Satellite Coax Jacks: Two pair of gold plated F-Connectors optimized for Satellite TV signal line protection.

Cable TV Coax Jacks: Gold plated F-Connectors optimized for Cable TV or non-amplified Rooftop Antenna signal line protection.

IEC Main Power

Ground Lug:

Filtered Outlet Bank 2:

Isolation Transformer

Voltage Sense Trigger Inputs:

 

 

 

 

Receptacle:

Provides a

Two Always-On, Balanced

Circuit Breaker:

3.5 mm Mono Mini-Plug jacks. Connect to a remote

Power cord connects

common

Double L filtered outlets

Opens in the event that

trigger device that provides 12VDC to trigger a startup

to this receptacle.

grounding point

for Low-Current analog

equipment connected

/ shutdown sequence. This is the second trigger that

 

for equipment

components such

to the Isolated Outlets

will activate the MAX ® 5510 turn-on or shutdown

 

with separate

as pre-amplifiers,

exceeds 4 amps current

sequence. (See switched outlets pushbutton on front

 

ground leads

receivers, VCR’s

draw. When white is

panel).

 

 

and tape decks.

visible, the breaker has

 

 

 

 

 

 

 

opened. Reduce the

 

 

 

 

 

 

 

load and push to reset.

Isolation Transformer Outlets Turn-Off Switch:

 

 

 

 

 

 

 

 

 

3-position slide switch. Allows adjustment of the

 

 

 

 

Turn-Off delay for the 4 Isolation Transformer Outlets.

 

 

 

 

Choose between “Always-On”, 10 and 30 seconds.

High-Current Outlets

Telephone Jacks:

Turn-On Switch:

In/Out connections

3-position slide switch.

for telephone line or

Allows adjustment of the

pay-per-view line

Turn-On delay for the 2

protection.

High-Current Outlets.

 

Choose between 0, 10

 

and 30 seconds.

 

4

 

1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com

Image 6
Contents MAX 5510 ACRegenerator Model # M5510 Table of Contents Before YOU BeginFiltration System is the Complete Solution IntroductionConnection Diagram Tri-Power Filtration SystemFeature Overview PushbuttonMeters Feature DetailsOn/Off/Dimmer Switch Convenience LampDiagnostic/Indicator Lights Sequential Startup/ShutdownFiltered Outlet Banks 1 Isolation Transformer Outlet BankHigh-Current Outlet Bank Voltage Sense TriggersCircuit Breakers SignalPerfect Telephone Line Protection SignalPerfect A/V Signal Line ProtectionSignalPerfect Coaxial Line Protection Power CordProtect or Disconnect AC Surge Protection SurgeGate Plus ProtectionTechnical Specifications Contacting PanamaxEmail custrelations@panamax.com Fax Isolated Power Power Modes in the MAXBalanced Power ConclusionFAQs