rated load and +/- 10% of input voltage changing.
2.4Load regulation
The load regulation for +24V is less then
2.5Step regulation
When +24V load changes from min. to peak load or from load to min. load , the 5V should keep within 5V
3.0General Features
3.1Efficiency
The efficiency is higher than 75% while measuring at nominal line and rated load.
3.2Hold up time
The old up time is longer than 16ms at 115VAC input and rated load, which is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
3.3Protection
For some reason the power supply fails to control itself, the
4.0Environment specifications
4.1Operation temperature
0 deg C to 50 deg C (Normal output current)
50 deg C to 75 deg C (65% output current)
4.2Storage temperature
4.3Altitude
will operate properly at any altitude between 0 to 10000ft.
2