SAFETY PRECAUTIONS

Use only a polarized 3- wire ac outlet. This assures that the power supply chassis, case, and ground terminal are connected to a good earth ground and reduces danger from electrical shock.

There is little danger of electrical shock from the power supply output, which produces a maximum of 30 volts dc. However, there

may be great danger of electrical shock if the power supply output is connected to an external high voltage. Some equipment being powered may contain high voltage and present a shock hazard. Observe caution. If the power supply output is floated (referenced to a voltage rather than earth ground) turn off the power supply and the equipment under test when making connections. Never float the power supply to a potential greater than 100 volts peak with respect to earth ground.

EQUIPMENT PRECAUTIONS

Avoid using the power supply in ambient temperatures above +40° C. Always allow sufficient air space around the heat sink at the rear of the power supply for effective radiation to prevent internal heat build- up.

Although the power supply is protected against reverse polarity damage, the circuit being powered may not include such protection. Always carefully observe polarity; incorrect polarity may damage the equipment under test.

11

Do not exceed the voltage rating of the circuit being powered. Many transistors and integrated circuits will not withstand voltage of 30 volts.

There is no need to worry about voltage spikes or overshoot damaging the equipment under test. The voltage between the output terminals of the power supply never exceeds the preset value as the POWER switch is turned on or off.

HOOK- UP

1.Turn off the power supply and the equipment to be powered during hook- up.

2.Connect the positive polarity of the device being powered to the red (+) terminal of the power supply.

3.Connect the negative polarity of the device being powered to the black (-) terminal of the power supply.

4.Fig. 3 illustrates the grounding possibilities.

a.If the negative polarity of the equipment or circuit being powered is also the chassis or common, it may be

grounded to earth by strapping the black (-) terminal to the green ( ) terminal as shown in Fig. 3A.

b.Similarly, the positive polarity can be grounded by strapping the red (+) terminal to the green ( ) terminal as shown in Fig. 3B.

Image 11
Contents Instruction Manual Test Instrument Safety DC Power Supply Table of Contents Introduction Amps FeaturesSpecifications Accessories Supplied SpecificationsTemperature Range Controls and Indicators Front Panel Controls and Indicators Controls and Indicators Rear Panel ControlsOperating Instructions Safety PrecautionsB. Grounding Possibilities Operating InstructionsD. Grounding Possibilities Set Fine Voltage control to center and Coarse Voltage Typical Constant Voltage OperationSetting Current Limit Setting Current LimitTypical Constant Current Operation Operating Instructions Typical Constant Current OperationConstant Voltage/Constant Current Characteristic Connecting TWO Power Supplies in SeriesLoad Load Page Electronics Manufacturing ApplicationsGeneral Electronics ServicingElectronics Education Battery ChargingApplication Electronics Design LAB Line Voltage CONVERSION, International Units MaintenanceFuse Replacement AdjustmentsInstrument Repair Service Maintenance 1735A CalibrationLocation of Adjustments MaintenancePage Service Information Limited Two-Year Warranty Test Instrument Safety Seguridad DE EL Instrumento DE Prueba Precauciones Manual de instrucciones Modelo 1735A Aplicaciones Tabla DE ContendidoIntroduccion Características Especificaciones Peso Rango DE TemperaturaControles Y Indicadores Controles E Indicadores Precauciones DEL Equipo Instrucciones DE OperacionPrecauciones DE Seguridad Figura a y B .Posibilidades de conecciones etierra Instrucciones DE OperaciónFigura 3 C y D Operacion Tipica DE Voltaje Constante Figura 5. Estableciendo el limite de correinte Estableciendo EL Limite DE CorrienteFigura 6.Tipica operación de corriente Conectando DOS Fuentes DE Pode EN Series Voltaje CONSTANTE/ Corriente Constante CaracteristicasCarga Figura 9. Conectando dos fuentes de poder en paralelo Conectando DOS Fuentes DE Poder EN Paralelo General AplicacionesCargado DE Bateria Laboratorio DE Diseno ElectronicoEducacion DE Electronica Conversion DE Linea DE VOLTAJE, Lineas Internacionales MantenimientoPrecaucion Remplazo DE FusibleServicio DE Reparacion DE EL Instrumento 1735A CalibracionPage Informacion DE Servicio DOS-ANOS DE Garantia Limitada Seguridad DE EL Equipo DE Prueba Declaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA 2005 B&K Precision Corp

0-30V, 0-3A specifications

The B&K 0-30V, 0-3A power supply is a versatile and reliable laboratory instrument designed for various applications in electronics and electrical engineering. Known for its precision and efficiency, this device is an essential tool for engineers, researchers, and hobbyists alike.

One of the main features of the B&K power supply is its adjustable output voltage ranging from 0 to 30 volts. This wide voltage range allows users to test and power a variety of electronic devices and circuits, ensuring compatibility with different components. The current output is rated at 0 to 3 amperes, providing ample power for most standard applications while adhering to safety standards and preventing overload situations.

The device employs advanced linear regulation technology, which guarantees low ripple and noise levels in the output signal. This ensures that sensitive electronic components receive a stable and clean power supply, which is crucial in maintaining the integrity of experimental results. Additionally, the linear design contributes to the longevity and durability of the power supply, making it an enduring choice for professionals.

Another notable characteristic is its user-friendly interface, featuring easy-to-read analog meters that provide real-time feedback on voltage and current levels. This feature enhances the precision of adjustments and simplifies the monitoring of power output during experiments. Moreover, the intuitive layout of controls allows users to make quick adjustments without navigating through complex menus.

The B&K 0-30V, 0-3A power supply is also designed with safety in mind. It incorporates overload protection and short circuit protection mechanisms, which safeguard both the power supply and the connected devices from damage. This level of protection is essential in laboratory settings where equipment cost can be significant.

In terms of build quality, the B&K power supply is constructed with robust materials that ensure impact resistance and reliability. Its compact design makes it easy to fit into crowded workbenches, while still providing ample connectivity options.

Overall, the B&K 0-30V, 0-3A power supply stands out in its category with its remarkable features, advanced technologies, and reliable characteristics. Its combination of precision, durability, and safety makes it a preferred choice for anyone involved in electronics testing, prototyping, and research. Whether in a professional laboratory or a DIY setting, this power supply delivers performance that meets the demanding needs of modern electronics.