Page 2

7URXEOHVKRRWLQJ

Use the table below to solve minor UPS installation or operation problems. Consult APC Online Technical Support or call APC Technical Support for assistance with problems that cannot be solved using the table below:

Possible Cause

Procedure

836￿ZLOO￿QRW￿WXUQ￿RQ

836￿6WRUDJH

If the UPS needs to be stored for extended periods of time, the battery needs to be charged periodically to maximize battery capacity. Before storing, charge the UPS for at least 10 hours. Store the UPS covered and upright in a cool, dry location.

The recommended period of time the unit can be stored without periodic charging is dependent on the storage temperature:

Extended Storage

Battery is not connected properly.

UPS not connected to AC power supply.

UPS circuit breaker “tripped”.

Very low or no utility voltage.

Utility overvoltage.

Check the battery connections. Consult “Connect battery wire” under “Setup” on the front page which shows how to access the battery and connect the wire.

Check that the UPS power plug is securely connected to the wall outlet.

Disconnect non-essential equipment from the UPS. Reset the circuit breaker (on back of UPS) by pushing the button back in. If the breaker resets, switch the UPS On and reconnect equipment one at a time. If the breaker trips again it is likely that one of the connected devices is responsible for the overload.

Check the wall outlet, that supplies power to the UPS, with a table lamp. If the lamp is very dim, have the utility voltage checked by a qualified electrician.

Connect the UPS to another wall outlet or have a qualified electrician check the building wiring.

Storage Temperature

Recharge Frequency

Charging Duration

5 to 86oF (-15 to 30oC)

Every 6 Months

10 Hours

86 to 113oF (30 to 45oC)

Every 3 Months

10 Hours

2UGHU￿5HSODFHPHQW￿%DWWHU\

The typical battery lifetime is 3-6 years (depending on number of discharge cycles and operating temperature). A replacement battery can be ordered from local retailers, APC, or the APC web site.

The APC part number for the APC Back-UPS Pro (350 or 500) Replacement Battery Cartridge is RBC2.

%DWWHU\￿5HSODFHPHQW

Battery replacement is a safe procedure. You may leave the UPS On and equipment connected during this procedure. Do not replace the battery when the UPS is On Battery.

Please consult the “Connect battery wire” diagrams (a through d) on the front page during this procedure.

836￿RSHUDWHV￿RQ￿EDWWHU\￿DOWKRXJK￿QRUPDO￿XWLOLW\￿YROWDJH￿H[LVWV

UPS’s circuit breaker “tripped”.

Disconnect non-essential equipment from

 

 

the UPS. Reset the circuit breaker (on

 

 

back of UPS) by pushing the button back

 

 

in.

 

 

 

 

The specific wall outlet the UPS is

Connect the UPS to another wall outlet or have a qualified

connected to does not supply utility

electrician check the building wiring.

voltage.

 

 

836￿GRHV￿QRW￿SURYLGH￿H[SHFWHG￿EDFNXS￿WLPH

1.Set the UPS at the edge of a table (diagram a).

2.Slide the battery compartment cover down (diagram b).

3.Grasp the tab attached to the battery and slide the battery partially out. Then grab the battery firmly and pull it out. The battery wires will disconnect as the battery is pulled out (diagram c).

4.Carefully insert the new battery halfway into the UPS, avoid pinching the wires (diagram d).

5.Connect the wires to the new battery:

Red wire - to red terminal

Black wire - to black terminal

Small sparks at the battery terminals are normal during connection.

The UPS is excessively loaded.

The UPS’s battery is weak due to recent outage and has not had time to recharge.

Battery requires replacement.

Unplug non-essential Battery Back-Up connected equipment, such as printers. They can be plugged into Surge Protection outlets.

Note: Devices that have motors or dimmer switches (laser printers, heaters, fans, lamps, and vacuum cleaners for example) should not be connected to the Battery Backup Plus Surge Protection outlets.

Charge the battery. The battery charges whenever it is connected to utility power. Typically, six to eight hours are needed to fully charge the battery from total discharge. UPS runtime is reduced until the battery is fully charged. You can perform a self test after the battery is fully recharged by pressing and holding the On/Test button for more than 1 second, then releasing it.

If the Replace Battery LED is lit, the battery should be promptly replaced. If the UPS is operated with a weakened battery, runtime will be significantly reduced. Battery capacity decreases with frequent power outages or when the UPS is operated at elevated temperatures. Batteries typically last 3-6 years.

6.Carefully insert the battery fully into the UPS (diagram d).

7.Slide the battery compartment cover back into place (diagram e).

The old battery must be recycled. Deliver the battery to an appropriate recycling facility or return it to APC in the packing carton that came with your new battery. Additional recycling information is provided with your new battery.

6HUYLFH

If the unit arrived damaged, notify the carrier.

If the UPS requires service, do not return it to the dealer. The following steps should be taken.

1.

Consult the Troubleshooting section to eliminate common problems.

2.

Verify that the circuit breaker is not tripped. A tripped circuit breaker is the most common UPS problem.

3.

If the problem persists, consult APC Online Technical Support or call APC Technical Support.

 

When calling APC Technical Support, have the model number of the UPS, the serial number and

 

the date purchased ready. Be prepared to troubleshoot the problem over the telephone with an APC

 

Technical Support representative. If this is not successful, APC will issue a Return Merchandise

 

Authorization number (RMA#) and a shipping address.

$￿UHG￿LQGLFDWRU￿LV￿OLW￿RU￿IODVKLQJ

The Overload indicator is lit if equipment

Move one or more pieces of equipment to the Surge

connected to Battery Backup outlets is

Protection outlets.

drawing more power than the UPS can

 

provide.

 

The Replace battery indicator is lit if the

The battery should be replaced within two weeks (see Order

battery is near the end of its useful life.

Replacement Battery). Failure to replace the battery may

 

result in insufficient runtime during a power outage.

The On Line and Overload indicators are

The UPS has entered sleep mode. This lasts for 16 seconds

flashing alternately.

during a power outage and is normal.

$OO￿LQGLFDWRU￿OLJKWV￿DUH￿IODVKLQJ

 

 

UPS failure

Call APC for service.

836￿GRHV￿QRW￿SRZHU￿WKH￿3&￿0RQLWRU￿GXULQJ￿DQ￿RXWDJH

 

 

Battery is not connected.

Check the battery connections. (See “Connect battery wire”

 

under “Setup” on the front page.)

PC and/or monitor is plugged into a Surge

Move PC and/or monitor to the Battery Backup plus Surge

Protection outlet.

Protection outlets.

A UPS under warranty will be repaired at no cost.

The standard warranty is 2 years from date of purchase. APC's standard procedure will be to replace

the original unit with a factory reconditioned unit. APC will ship out the replacement unit once the

defective unit has been received by the repair department or cross ship upon the receipt of a valid

credit card number. The customer pays for the shipping to APC and APC pays ground freight

transportation costs back to the customer.

Customers who must have the original unit back due to assigned asset tags and set depreciation

schedules must declare such a need at first contact with an APC Technical Support representative.

If the warranty has expired, there is a repair charge.

4. For Return:

Disconnect the black wire from the UPS battery. Department of Transportation (DOT) regulations

require that the black battery wire be disconnected before shipping the UPS back to APC. Refer to

“Connect battery wire” instructions and graphics on the front page for how to disconnect the black

wire from the battery.

Pack the UPS in its original packaging. If the original packing is not available, contact APC

Technical Support to obtain a new set. Pack the UPS properly to avoid damage in transit.

Never use Styrofoam™ beads for packaging. Damage sustained in transit is not covered

under warranty (insuring the package for full value is recommended).

Write the RMA# on the outside of the package.

6SHFLILFDWLRQV

Acceptable Input Voltage

Input Voltage (on line)

Output Voltage

Frequency Limits (on line)

Maximum Load

Typical Recharge Time

Operating Temperature

Storage Temperature

Operating and Storage Relative Humidity

0 - 160 Vac, Single Phase

90 - 133 Vac

103 -133 Vac

47 - 63 Hz (autosensing)

350 VA - 220 W 500 VA - 315 W

6 to 8 hours from total discharge

32 to 104°F (0 to 40°C)

5 to 113°F (-15 to 45°C)

0 to 95%, non-condensing

Return the UPS by insured, prepaid carrier to the address given to you by Technical Support.

$3&￿&RQWDFW￿,QIRUPDWLRQ

USA/Canada …………….

1.800.800.4272

Mexico……………………

292.0253 / 292.0255

Brazil …………………….

0800.12.72.1

Worldwide ………………

1.401.789.5735

 

 

 

Size (H x W x D)

9.4 x 5.0 x 7.9 in

(23.9 x 12.7 x 20.0 cm)

Weight

350 VA -14.2 lb (6.4 kg)

500 VA - 15.4 lb (6.9 kg)

Shipping Weight

350 VA - 16.2 lb (7.4 kg)

500 VA - 17.8 lb (8.1 kg)

EMI Classification

FCC/DOC Class B certified

Note: Detailed UPS product specifications are available online at the APC web site or through the APC faxback system ( 800-347-3299).