APC RS 550 manual Function Button Quick-Reference, Description, Timing, Seconds

Page 5

Function Button Quick-Reference

Function

Button

Timing

UPS

Description

(seconds)

Status

 

 

 

 

 

Power

 

 

 

 

Power On

Power Off

0.2Off

2 On

Press POWER to start receiving input utility power. If A/C input power is not available, the unit will run on battery power.

The unit is not receiving input utility power, but is providing surge protection.

Display

Status Inquiry

Full-Time/Power- Saving mode

Mute

0.2On

2 On

Verify the status or condition of the unit. The LCD will illuminate for 60 seconds.

The LCD will illuminate and the unit will beep to confirm the Full-Time mode. The LCD will darken and the unit will beep to confirm the Power-Saving mode. While in Power-Saving Mode, the LCD will illuminate if a button is pressed, then darkens after 60 seconds of no activity.

Event Specific

0.2

On

Disable any audible alarms caused by an event.

General Status Enable/

2

On

Enable or disable the audible alarms. The Mute icon will

Disable

 

 

illuminate and the unit will beep one time. The Mute function will

 

 

 

 

not activate unless the UPS is operating on battery power.

 

 

 

 

 

Sensitivity

6

Off

The Load Capacity icon will blink, indicating that the unit is in

 

 

 

 

programming mode. Use the POWER button to scroll through

 

 

 

 

 

 

 

 

Low, Medium, and High, stop at selected sensitivity. The unit will

 

 

 

 

beep to confirm selection. See Configuration for details.

 

 

 

 

 

Master/Controlled

2

On

The leaf icon will darken indicating that the Master Outlet feature

outlet Enable/Disable

 

 

is disabled or illuminate to indicate the Master Outlet feature is

 

 

 

 

enabled. The unit will beep once.

 

 

 

 

 

Master/Enable

6

On

While calibrating the threshold setting, the device connected to

Threshold

 

 

the Master Outlet should be turned off or placed in Standby or

Calibration

 

 

Sleep mode. Upon completion, Power-Saving icon will flash 3

 

 

 

 

and beep 3 times.

 

 

 

 

 

Self-Test (manual)

6

On

The UPS will perform a test of the internal battery. Note: This

 

 

 

 

will happen automatically when the unit is turned ON.

 

 

 

 

 

Event Reset

 

0.2

On

When the Event screen is visible, press and hold DISPLAY, then

 

 

 

 

press POWER, to clear the utility failure event counter.

 

 

 

 

 

Fault Reset

2

Fault

After a fault has been identified, press POWER to remove the

 

 

 

 

visual indication and return to standby status.

Back-UPS® RS Installation and Operation

5

Image 5
Contents Connect the battery SafetyInventory OverviewConnect the equipment Install PowerChute Personal Edition softwareOperation Connect the equipmentConfiguration Low sensitivity Medium sensitivity High sensitivity System FaultsUnit sensitivity Function Button Function Button Quick-ReferenceDescription TimingProblem Possible Cause Corrective Action TroubleshootingService SpecificationsWarranty APC Worldwide Customer Support