Troubleshooting
Use the tables below to solve minor
Possible Cause | Procedure |
|
|
Back-UPS will not switch on
Check that the | |
power source. | securely connected to the wall outlet. |
| Disconnect |
| ||||||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
| ||||||||
|
| on the rear panel of the |
|
|
|
|
|
|
|
| ||
|
| ing the circuit breaker button fully inward |
|
|
|
|
|
|
|
| ||
|
| until it catches. If the circuit breaker resets, |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||||||
|
| switch the |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||||||
|
| equipment |
|
|
|
| ||||||
|
|
|
|
| ||||||||
|
| breaker trips again, it is likely that one of the |
| |||||||||
|
| connected devices is causing the overload. |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Very low or no utility voltage. | Check the wall outlet that supplies power to |
|
|
| |||||||
|
| |||||||||||
|
| the |
|
|
| |||||||
|
|
|
|
| ||||||||
|
| bulb is very dim, have the utility voltage |
|
|
|
|
| |||||
|
| checked by a qualified electrician. |
|
|
|
|
| |||||
|
|
|
|
|
|
|
| |||||
|
|
|
| |||||||||
| Portable generator being used to | Set the Transfer Voltage and Sensitivity |
| |||||||||
| provide input voltage. | setting to Low (see Transfer Voltage and |
| |||||||||
|
| Sensitivity Adjustment). By setting the Back- |
| |||||||||
|
| UPS to Low sensitivity, it can accept a wider |
| |||||||||
|
| range of input voltage. |
|
Internal battery is not connected. | Check the battery connections |
|
|
Computer, monitor or external disk/ | Move computer, monitor, or external drive power cord plug to the |
Battery Backup outlets. | |
Surge Only outlet. |
|
|
|
Disconnect |
|
|
|
| |
|
|
|
| ||
|
|
|
|
| |
| on the rear panel of the |
|
|
|
|
| ing the circuit breaker button fully inward |
|
|
|
|
| until it catches. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
The wall outlet that the | Connect the | ||||
connected to does not supply utility | electrician check the building wiring. | ||||
power to the unit. |
|
|
|
|
|
Back-UPS does not provide expected backup time
Unplug | |
| printers and plug them into Surge Only outlets. |
| Note: Devices that have motors or dimmer switches (laser printers, |
| heaters, fans, lamps, and vacuum cleaners, for example) should not be |
| connected to the Battery Backup outlets. |
|
|
| Charge the battery. The battery charges whenever the |
recent outage and has not had time | connected to a wall outlet. Typically, eight hours of charging time are |
to recharge. | needed to fully charge the battery from total discharge. |
| |
|
|
Battery requires replacement. | Replace battery (see Order Replacement Battery). Batteries typically |
| last |
| vated temperatures. |
|
|
A red indicator is lit
Battery is not connected properly. | Check the battery connections. |
|
|
The Overload indicator is lit if | Move one or more equipment power plugs to the Surge Only outlets. |
equipment connected to the Battery |
|
Backup outlets is drawing more |
|
power than the |
|
vide. |
|
|
|
Battery requires replacement. | The battery should be replaced within two weeks (see "Order |
| Replacement Battery"). Failure to replace the battery will result in |
| reduced |
|
|
Red indicators are flashing
Call APC for service. | |
|
|
Replace Battery indicator lit and an alarm sounds when the
Internal battery not connected. | Check the battery connections. |
|
|
Specifications
Input Voltage (on line) | 180 - 266 Vac (default setting) | |
|
| |
Frequency Limits (on line) | 47 - 63 Hz | |
|
| |
On Battery Waveshape | Stepped Sine Wave | |
|
| |
Maximum Load | 350 VA - 210 W 500 VA - 300 W 650 VA - 400 W | |
|
| |
Typical Recharge Time | 8 Hours | |
|
| |
Operating Temperature | 0o to 40oC (32o to 104oF) | |
Storage Temperature | ||
Operating and Storage | 5 to 95% | |
Relative Humidity |
|
|
|
|
|
Size (H x W x D) | 16.5 x 9.2 x 28.5 cm | (6.5 x 3.6 x 11.2 inches) |
|
|
|
Weight | 350 VA - 5.7 kg (12.5 lb) | 500 VA - 5.9 kg (12.9 lb) |
| 650 VA - 6.2 kg (13.6 lb.) | |
|
|
|
Shipping Weight | 350 VA - 6.8 kg (14.9 lb) | 500 VA - 7.0 kg (15.3 lb) |
| 650 VA - 7.3 kg (16.1 lb.) | |
|
| |
EMI Classification | EN 55022, IEC | |
|
| |
On Battery | 350 VA - 13.2 minutes (typical) - computer and | |
| 17" (43.2 cm) monitor. | |
| 500 VA - 10.8 minutes (typical) - computer and | |
| 21" (53.3 cm) monitor. | |
| 650 VA - 17 minutes (typical) - computer and | |
| 21" (53.3 cm) monitor. | |
|
|
|
Back-UPS Storage
Before storing, charge the
Storage Temperature | Recharge Frequency | Charging Duration |
Every 6 months | 8 hours | |
30o to 45oC (86o to 113oF) | Every 3 months | 8 hours |
Please contact APC Technical Support to troubleshoot the unit before returning it to APC.
Service
Note: If the UPS requires service, do not return it to the dealer. The following steps should be taken:
1.Consult the Troubleshooting section to eliminate common problems.
2.Determine if the circuit breaker is tripped. If the circuit breaker is tripped, reset the breaker and determine if the problem still exists.
3.If the problem persists, consult the APC Worldwide Web site (www.apcc.com) or call customer service.
•Record the model number of the UPS, the serial number, and the date purchased. Be prepared to troubleshoot the problem over the telephone with a technician. If this is not successful, the technician will issue a Return Merchandise Authorization Number (RMA#) and a shipping address.
•If the UPS is under warranty, repairs are free. If not, there is a repair charge.
4.Pack the UPS in its original packaging. If the original packing is not available, ask customer service about obtaining a new set. Pack the UPS properly to avoid damage in transit.
Note: Never use StyrofoamTM beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is recommended).
5.Write the RMA# on the outside of the package.
6.Return the UPS by insured, prepaid carrier to the address provided by customer service.
Warranty
The standard warranty is two (2) years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement to the customer.
APC Contact Information
|
|
|
| USA/Canada | 1.800.800.4272 | |
|
|
|
|
|
| |
|
|
|
| Mexico | 292.0253 / 292.0255 | |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
| Brazil | 0800.12.72.1 | |
1 | 2 | 3 |
|
|
| |
Worldwide | 1.401.789.5735 | |||||
4 | 5 | 6 |
| |||
7 | 8 | 9 |
|
|
| |
Internet | http:\\www.apc.com | |||||
* | 0 | # |
| |||
|
|
| ||||
|
|
|
| Technical Support | http:\\www.apc.com/support | |
|
|
|
|
|
| |
|
|
|
|
|
|
Copyright © 2004 American Power Conversion. All rights reserved.