APC 3000 VA, 1500 VA, SUM3000RMXL2U user manual User Configurable Items

Page 10

4:USER CONFIGURABLE ITEMS

NOTE: SETTINGS ARE MADE THROUGH THE SUPPLIED POWERCHUTE SOFTWARE OR

THE NETWORK INTERFACE CONNECTION. REFER TO THE SOFTWARE HELP GUIDES FOR DETAILS.

FUNCTION

FACTORY

USER SELECTABLE

DESCRIPTION

DEFAULT

CHOICES

 

 

Automatic Self-Test

Every 14 days

Every 14 days

This function sets the interval at which the

 

(336 hours)

(336 hours),

UPS will execute a self-test.

 

 

Every 7 days

 

 

 

(168 hours),

 

 

 

On Startup Only,

 

 

 

No Self-Test

 

 

 

 

 

UPS ID

UPS_IDEN

Up to eight characters

Use this field to uniquely identify the UPS,

 

 

 

(i.e. server name or location) for network

 

 

 

management purposes.

 

 

 

 

Date of Last Battery

Manufacture Date

mm/dd/yy

Reset this date when you replace the inter-

Replacement

 

 

nal battery module.

 

 

 

 

Minimum Capacity

0 percent

0, 15, 30, 45, 60, 75, 90

The UPS will charge its batteries to the

Before Return from

 

percent

specified percentage before powering up

Shutdown

 

 

connected equipment, following a low-

 

 

 

battery shutdown.

 

 

 

 

Voltage Sensitivity

High

High, Medium, Low

The UPS detects and reacts to line voltage

 

 

 

distortions by transferring to battery power

 

 

 

to protect the connected equipment. When

 

 

 

power quality is poor, the UPS may fre-

 

 

 

quently transfer to battery power. If the

 

 

 

connected equipment can operate normally

 

 

 

under such line voltage conditions, reduce

 

 

 

the sensitivity setting to conserve battery’s

 

 

 

capacity and service life.

 

 

 

 

Alarm Control

Enable

Enable, Mute, Disable

User can mute an ongoing alarm or disable

 

 

 

all existing alarms permanently.

 

 

 

 

Shutdown Delay

90 seconds

90, 180, 270, 360, 450,

The interval is set between the times when

 

 

540, 630, 0 seconds

the UPS receives a shutdown command and

 

 

 

when it shuts off power to the outlets.

 

 

 

 

Low Battery Warning

2 minutes

2, 5, 8, 11, 14, 17, 20,

PowerChute software provides automatic,

 

 

23 minutes

unattended shutdown when the remaining

 

 

 

battery runtime matches this setting while

 

 

 

on battery.

 

 

 

Change the low battery warning interval

 

 

 

default setting to the time that the operating

 

 

 

system or system software requires to

 

 

 

safely shut down.

 

 

 

 

Synchronized Turn-on

0 seconds

0, 60, 120, 180, 240,

The UPS will wait the specified time after

Delay

 

300, 360, 420 seconds

the return of utility power before turn-on

 

 

 

(to avoid branch circuit overload).

 

 

 

 

8

Image 10
Contents APC Smart-UPS Page Unpack IntroductionPosition the UPS in the Specified Environment Mount the UPS in the Rack and Connect the Battery Tower Configuration Start the UPS Connect Equipment to the UPSConnect the UPS to the Network if Applicable Ethernet PortBattery Operation Front Display Panel IngAffect the voltage display User Configurable Items VAC Power Processing Module Replacement Battery Module MaintenanceStorage Service ShippingTroubleshooting Tion, the UPS must be turned off and then on againStorage, Maintenance, Transporting, and Service While online or on battery,3000 VA, 120 V model only Replace battery LED flashes Models and 1500VA Transporting, and ServiceModel only UPS input Regulatory and Warranty Information Limited Warranty
Related manuals
Manual 2 pages 20.78 Kb Manual 8 pages 63.66 Kb Manual 18 pages 5.42 Kb Manual 8 pages 27.08 Kb Manual 6 pages 273 b

SUM3000RMXL2U, 3000 VA, 1500 VA specifications

The APC 420 VA, RBC3, 1500 VA, and RBC4, 450 are essential components designed to provide reliable backup power and surge protection for critical electronic devices and systems. These products are crucial for both home and office environments, ensuring that sensitive equipment remains operational during power outages or fluctuations.

The APC 420 VA model is a compact uninterruptible power supply (UPS) designed for basic power protection, suitable for personal computers and home networks. It features a capacity of 420 VA, allowing users to safeguard essential devices against unexpected power interruptions. With its multiple output outlets, this UPS ensures that various devices can be connected simultaneously. One of the main highlights is its short recharge time, which guarantees that the unit is ready to provide backup power when needed.

The RBC3 battery is specifically designed for APC UPS systems, providing a reliable replacement option to ensure consistent performance. This RBC (Replacement Battery Cartridge) uses advanced sealed lead-acid technology that delivers a dependable power source. It is maintenance-free and designed for easy installation, making it a user-friendly choice for anyone needing to refresh their UPS capabilities.

Next, the APC 1500 VA is a more robust UPS unit, ideal for protecting critical devices in a business setting. With its higher capacity of 1500 VA, it offers longer backup times and the ability to connect more equipment. This model incorporates smart battery management technology that enhances battery health and longevity while providing real-time monitoring of power conditions.

The RBC4, rated at 450, complements the larger APC units, delivering reliable efficiency and performance. Like the RBC3, it features sealed lead-acid technology, ensuring safe and stable operation. This battery also boasts a long lifespan, minimizing the need for frequent replacements and contributing to lower operational costs.

In summary, the integration of the APC 420 VA, RBC3, 1500 VA, and RBC4, 450 presents an effective solution for anyone seeking reliable power protection. They offer essential features such as multiple outlets, advanced technology for optimal performance, and user-friendly maintenance options. Together, they cater to a wide range of applications, ensuring that users always have access to uninterrupted power whenever needed.