APC 120 Vac Customize the Main and Switched Outlet Groups, Network Management Card Settings

Page 12

Customize the Main and Switched Outlet Groups

Use the Configuration menus to change the Main Outlet Group and the Switched Outlet Group settings.

Function

Factory Default

Options

Description

 

 

 

 

Name String

Outlet Group 1

Edit these names using an external interface, such as the Network

Outlet Group

 

 

 

Management Card Web interface.

UPS Name String

UPS Outlets

 

 

 

 

 

 

Turn On Delay

0 sec

Set the value in

The amount of time the UPS or a Switched Outlet

 

 

seconds

Group will wait between receiving the command to

 

 

 

turn on and the actual startup.

 

 

 

 

Turn Off Delay

• 0 sec (UPS Outlets)

Set the value in

The amount of time the UPS or a Switched Outlet

 

• 90 sec (Switched

seconds

Group will wait between receiving the command to

 

Outlet Groups)

 

turn off and the actual shut down.

 

 

 

 

Reboot Duration

8 sec

Set the value in

The amount of time the UPS or a Switched Outlet

 

 

seconds

Group must remain off before it will restart.

 

 

 

 

Minimum Return

0 sec

Set the value in

The amount of battery runtime that must be available

Time

 

seconds

before the UPS or a Switched Outlet Group will turn

 

 

 

on after a shutdown.

 

 

 

 

Load Shed On

Disabled

• Enable

When the unit switches to battery power, the UPS

Battery

 

• Disable

will disconnect power to the Switched Outlet Group

 

 

 

to save battery runtime.

 

 

 

Configure this delay time, use the LOAD SHED TIME

 

 

 

WHEN ON BATTERY setting.

 

 

 

 

Load Shed Time

1800 sec

Set the value in

The amount of time the outlets will function on

when On Battery

 

seconds

battery power before they will turn off.

 

 

 

 

Load Shed On

Disabled

• Enable

When the battery runtime falls below the specified

Runtime

 

• Disable

value, the Switched Outlet Group will turn off.

 

 

 

Configure this time using the LOAD SHED RUNTIME

 

 

 

REMAINING setting.

 

 

 

 

Load Shed On

120 sec

Set the value in

When the remaining runtime reaches this level, the

Runtime

 

seconds

Switched Outlet Group will turn off.

Remaining

 

 

 

 

 

 

 

Load Shed on

Disabled

• Disabled

In the event of an overload (greater than 107%

Overload

 

• Enabled

output), the Switched Outlet Group will immediately

 

 

 

turn off to conserve power for critical loads. The

 

 

 

Switched Outlet Group will only turn on again with

 

 

 

a manual command.

 

 

 

 

Network Management Card Settings

These settings are available only on units that have a Network Management Card (NMC) and are set at the factory. These settings can only be modified using an external interface, such as the NMC Web interface.

NMC IP Address Mode

NMC IP Address

NMC Subnet Mask

NMC Default Gateway

10

Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac 500 VA 100 Vac Tower

Image 12
Contents Smart-UPS Page Safety and General Information SpecificationsOverview Product DescriptionFront panel features Rear panel features 500 VA to 1500 VA modelsProduct Overview 500/750/1000/1500 VAInstallation Rear panel features 2200 VA and 3000 VA models2200 VA 120 Vac 2200/3000 VA 230 VacRear Panel Features OperationConnect Equipment Using the display interface Display PanelStandard menus Advanced menus ControlLog Configuration UPS SettingsStart-up Settings Function Factory Default Options DescriptionNominal Output Main Outlet Group and Switched Outlet Group Using the Main and Switched Outlet GroupsOverview Customize the Main and Switched Outlet Groups Network Management Card SettingsEmergency Power Off Normally open contactsNormally closed contacts Troubleshooting Problem and Possible Cause SolutionService Transport the unitSmart-UPS Factory Warranty Limited WarrantyPage APC Worldwide Customer Support 990-3534C 2012
Related manuals
Manual 8 pages 63.66 Kb Manual 5 pages 44.12 Kb Manual 8 pages 27.08 Kb Manual 14 pages 30.59 Kb Manual 19 pages 28.39 Kb Manual 2 pages 20.78 Kb Manual 6 pages 273 b

1000/ VA, SMT1500X413, 100 VAC, 120 Vac, 3000 VA specifications

The APC 420 VA, RBC3, 1500 VA, and RBC4, 450 are essential components designed to provide reliable backup power and surge protection for critical electronic devices and systems. These products are crucial for both home and office environments, ensuring that sensitive equipment remains operational during power outages or fluctuations.

The APC 420 VA model is a compact uninterruptible power supply (UPS) designed for basic power protection, suitable for personal computers and home networks. It features a capacity of 420 VA, allowing users to safeguard essential devices against unexpected power interruptions. With its multiple output outlets, this UPS ensures that various devices can be connected simultaneously. One of the main highlights is its short recharge time, which guarantees that the unit is ready to provide backup power when needed.

The RBC3 battery is specifically designed for APC UPS systems, providing a reliable replacement option to ensure consistent performance. This RBC (Replacement Battery Cartridge) uses advanced sealed lead-acid technology that delivers a dependable power source. It is maintenance-free and designed for easy installation, making it a user-friendly choice for anyone needing to refresh their UPS capabilities.

Next, the APC 1500 VA is a more robust UPS unit, ideal for protecting critical devices in a business setting. With its higher capacity of 1500 VA, it offers longer backup times and the ability to connect more equipment. This model incorporates smart battery management technology that enhances battery health and longevity while providing real-time monitoring of power conditions.

The RBC4, rated at 450, complements the larger APC units, delivering reliable efficiency and performance. Like the RBC3, it features sealed lead-acid technology, ensuring safe and stable operation. This battery also boasts a long lifespan, minimizing the need for frequent replacements and contributing to lower operational costs.

In summary, the integration of the APC 420 VA, RBC3, 1500 VA, and RBC4, 450 presents an effective solution for anyone seeking reliable power protection. They offer essential features such as multiple outlets, advanced technology for optimal performance, and user-friendly maintenance options. Together, they cater to a wide range of applications, ensuring that users always have access to uninterrupted power whenever needed.