Oki RS-422 manual Control Panel Error Messages, Obtaining Help and Information

Page 22

3-2

RS-232C/RS-422 Serial Interface Option

Control Panel Error Messages

About this Chapter

This chapter discusses troubleshooting error messages appearing on the printer’s control panel. Sources of help, information and technical support are also discussed.

Control Panel Error Messages

The format of control panel error messages is:

NETx: ERROR y

where x indicates the network slot where the serial interface is installed

and

where y reflects the error number as shown below:

Error No.

Description

Action Required

 

 

 

1

Overrrun Error

Verify that all DTS, RTS and XON settings within

 

 

the SERIAL SETUP menu are configured correctly.

 

 

Check the pinout assignments of cabling between

 

 

the printer and the host.

 

 

 

2

Parity Error

Verify that the PARITY setting within the SERIAL

 

 

SETUP menu is configured correctly.

 

 

Check the pinout assignments of cabling between

 

 

the printer and the host.

 

 

 

3

Framing Error

Verify that the SERIAL MODE, BAUD RATE,

 

 

DATA BITS, STOP BITS and PARITY settings

 

 

within the SERIAL SETUP menu are configured

 

 

correctly.

 

 

 

4

Flow Control Error

Verify that all DTS, RTS and XON settings within

 

 

the SERIAL SETUP menu are configured correctly.

 

 

Check the pinout assignments of cabling between

 

 

the printer and the host.

 

 

 

Example

An error message of:

NET2: ERROR3

indicates that the serial interface which is located in network slot 2 has experienced a framing error.

Obtaining Help and Information

Several sources of help and information are available, depending on the type of help you need:

Image 22
Contents User Guide RS-232C/RS-422 Serial Interface Option Proprietary Statement TrademarksCopyright Notice How This Guide is Organized Features of the RS-232C/RS-422 Serial InterfacePrinter Requirements Safety Precautions Contents Troubleshooting Chapter About this Chapter RS-232C/RS-422 Serial Interface Option RS-232C/RS-422 Serial Interface Option RS-232C/RS-422 Serial Interface Option RS-232C/RS-422 Serial Interface Option Using the RS-232C/RS-422 Serial Interface Control Panel Menu structure PCLRS-232C/RS-422 Serial Interface Option Serial Setup Menu Parity DTR ErrorRTS Error DTR Ready/BusyDisabling the Serial Interface RS-232C Serial Cable Pin Assignments References for OpenVMS usersRS-422 Serial Cable Pin Assignments RS-422 Serial Cable Pin Assignments Troubleshooting Control Panel Error Messages Obtaining Help and InformationYour Application Vendor Technical SupportYour Point of Purchase OKI ResourcesTechnical Support