AMT Datasouth 6000 manual Special Switch Settings, Switch number Special Condition

Page 46

Switches 6, 7 and 8 are used to determine the printer's Baud Rate.

6

7

8

 

 

 

 

 

 

 

 

Baud rate

 

 

 

 

OFF

OFF

OFF

9600 (default)

 

 

 

 

ON

OFF

OFF

2400

 

 

 

 

OFF

ON

OFF

4800

 

 

 

 

ON

ON

OFF

19200

 

 

 

 

OFF

OFF

ON

38400

 

 

 

 

ON

ON

ON

Special Setting:

9600 and for barcode reader

 

 

 

 

 

 

 

Special Switch Settings:

Switch number

1

2

3

4

5

6

7

8

Special Condition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets Baud Rate to 9600 for a Bar Code

N/A

N/A

N/A

N/A

N/A

On

On

On

Reader

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clears Objects in Flash ** emulation

N/A

N/A

On

N/A

On

N/A

N/A

N/A

specific

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N/A - Switch position has not function in the condition.

Note: Make sure to set switch 3 and 5 their original positions.

Fastmark 6000 Series

User's Guide 45

Image 46
Contents User’s Guide Important Safety Instructions Other Notices Conventions Table of Contents Appendix C Printer Status Appendix a Printer SpecificationsAppendix B Interface Specifications Appendix E Fonts and BAR Codes for PplaTable of Figures This page is blank Product Description Overview Unpacking and Inspection Setting up the Printer Front and Side ViewFM 6000 Series Back Panel Connecting the Power Cord Power Cord ConnectionConnecting the Printer to Your Host Communication CableFactory default parameters of serial port are Inside the Printer Inside PrinterOpen Top Access Cover Loading the RibbonPrinthead Latch and Side Access Cover Ribbon Take-up Ribbon Routing Fully open Top Access Cover Loading MediaMedia Supply Outside Media Guide Media Sensor Adjustment Users Guide Fastmark 6000 Series Media Routing Changing Position of the Media Supply Spindle Media Supply Spindle LocationCalibrating Media Sensors Correct calibration can result in loss of gap detectionPerforming the Self Test Self Test Pattern for Ppla Self Test PplaResetting the Printer to Factory Default Settings Front Panel Fastmark 6000 Series Front PanelLED Indicators Ready Media RibbonPressed and held down during Power UP ButtonsPressed during normal operation Pressed for Special functionsLCD Display Standard PrinterWith Barcode Reader Option With Keyboard Option installedAbnormal Conditions LCD and Button functionality in Set-up mode Front Panel Set-up MenuProcedure to Enter into Set-up Mode Entering into Set-up ModeSet-up Mode Selection Items Range Factory Default RemarksUsers Guide Fastmark 6000 Series Setting Display Language Range Factory DefaultThis page is blank Back Panel Back Panel FM6000 SeriesBack Panel Switches Standard Switch SettingsSpecial Switch Settings Switch number Special ConditionPS/2 Keyboard I/F System Setting Commands Command Set for PplaCommand Description Parameter Factory default Interaction Commands Symbol Code hexadecimalSystem Level Commands Command Description RemarksFormatting Commands Command DescriptionCommand structure Command function Editing CommandsComponents Description Variables Command Object Command Structure Description BaaabbbcccdddFont Downloading Commands Such commands are only used for soft fonts with PCL formatThis is a blank Printer Driver Driver Installation \WIN95 A\NT40 A\WIN98 A\WIN2000How to Use the Driver Parameter settingPrint using the following driver Details Tab Print to the following portPaper Paper size OrientationCopies Paper sourceMedia choice More OptionsDevice Options This is a blank LCD Displays Media OUT TroubleshootingReady and Media LEDs blinking Ready and Ribbon LED BlinkingHost indicates Printer Time Out LCD display Possible Problems and Solutions RemarksOnly the Ready LED blinks Data has been sent, but there is no output from the printerRecovery Poor printout qualityPreventive Maintenance Cleaning the Printhead Thermal PrintheadCleaning the Platen roller Cleaning the media compartmentThis is a blank General Specifications Specification Model FM6602Fonts, Bar Codes and Graphics Optional AccessoriesSpecification Model FM6402 Printer Programming Language A, PplaIntroduction SerialConnection with host Serial port settings Parallel Centronics Auto PollingAppendix C Printer Status Appendix D Ascii Table Internal Fonts FontCourier Font Set Internal Bar Codes Users Guide Fastmark 6000 Series AMT Datasouth Corp

6000 specifications

AMT Datasouth 6000 series printers are a robust and versatile solution for businesses looking to streamline their printing processes. Known primarily for their durability and efficiency, these printers cater to a wide range of applications, making them popular in various industries such as manufacturing, logistics, and warehousing.

One of the standout features of the AMT Datasouth 6000 series is its exceptional print speed. Capable of producing high-quality labels and documents quickly, it significantly boosts productivity. Businesses that require large volumes of printing will find the speed of the 6000 series particularly beneficial.

The printer employs advanced thermal transfer technology, which ensures consistent, high-quality prints. This method utilizes heat to transfer ink from a ribbon onto the media, resulting in sharp, legible text and graphics. Additionally, the printer supports a variety of label formats, including both paper and synthetic materials, allowing users to choose the right media for their specific needs.

In terms of connectivity, the AMT Datasouth 6000 series offers multiple options. Standard interfaces include USB and Ethernet, ensuring easy integration into existing networks. This capability is essential for businesses that rely on centralized printing solutions or need to connect multiple printers across a facility.

Another notable characteristic of the AMT Datasouth 6000 is its user-friendly design. The printer features an intuitive control panel that simplifies operation and enables users to manage printing tasks efficiently. With easy access to the printer’s components, maintenance becomes straightforward, minimizing downtime and ensuring that printers remain operational.

Additionally, the build quality of the AMT Datasouth 6000 series is worth mentioning. Constructed with durable materials, these printers are designed to withstand the rigors of industrial environments. This resilience minimizes the risk of breakdowns and extends the printer's lifespan, making it a cost-effective choice for long-term use.

The printer is also equipped with advanced software that enhances its functionality. Features such as compatibility with various design programs and the ability to create custom templates empower users to produce tailored labels and documents, addressing specific business needs.

Overall, the AMT Datasouth 6000 series stands out for its combination of speed, quality, and versatility. Its advanced technologies and user-friendly design make it a reliable choice for businesses looking to enhance their printing capabilities while maintaining operational efficiency.