About lamp

The product’s light source is a mercury lamp that lights at increased internal pressure. Be sure to fully understand the following characteristics of the lamp and handle it with extreme care.

• The lamp may explode with a loud noise due to impact or deterioration, or fail to light at

the expiration of its life.

• How long it takes before the lamp explodes or the life expires may vary greatly by lamp.

Some may explode shortly after first use. (Free replacement is available if the lamp

1Unplug power cord.

2Wait until lamp is sufficiently cooled.

Wait for at least 1 hour.

explodes within the warranty period. Contact the dealer from whom you purchased the

product in such a case.)

• Explosion is likely to happen if the lamp is used after the replacement period has elapsed.

• When the lamp explodes, the broken pieces of glass may get inside the product or be

released outside from the openings for ventilation.

• When the lamp explodes, a slight amount of mercury gas enclosed in the lamp along

with glass dust may be released from the openings for ventilation.

Immediately replace the lamp when a sign appears on the screen.

3Remove the lamp cover.

Loosen the 1 screw, then pull up to the direc- tion of the arrow with your fingers as shown to remove the lamp cover. Use care to avoid any damage to nails and/or tip of your finger(s). If you have any difficulty in removal, you can use a screwdriver or any other smaller tool for your convenience.

3

Lamp cover

1

2

When the replacement time approaches, a message will appear on the screen.

The risk of explosion will increase if the lamp is continuously used without being replaced.

• Frequently check the used hours and prepare spares when the replacement time

 

approaches. (Refer to “Status display”. p.33 )

When the lamp is broken

• If glass components, including a lamp and a lens, should break, handle the broken

 

pieces with care to avoid injury and contact your dealer for repair service.

• In the event of lamp explosion, unplug the product from the wall outlet, leave and

 

completely ventilate the room. Then, thoroughly clean the area around the projector and

 

discard any edible items placed in that area.

• When the lamp explodes, consult a doctor if glass dust or mercury gas gets into your

 

eyes or you breathe it.

Lamp replacement

A lamp is consumable supplies. If used for extended periods, images will appear dark, and the lamp could burn out. This is characteristic of a lamp, and is not malfunction. (The lifetime of the lamp depends on condition of use.) If this happens, replace it with a new one.

WARNING

If the projector is mounted on a ceiling, request a lamp replacement from your projector dealership.

When replacing, always use lamp “TLPLW3” (sold separately).

CAUTION

If you have been using the projector, the lamp will be very hot, and may cause burn injuries. Wait for the lamp to cool (for longer than 1 hour) before replacing it.

If the lamp should break, please handle with care to avoid injury due to broken pieces and contact your dealer for repair service.

4

Pull out the lamp.

1

 

Loosen the 2 screws holding the lamp in place,

4

 

and pull up the handle to remove the lamp.

2

 

 

5

Mount the new lamp.

 

Align the orientation, press down until the bottom is reached, and lock in place using the two lamp locking screws.

6 Replace the lamp cover.

2

5

Align the cover, and press it in, then tighten the

1

screws loosened in step 3 until the lamp cover is

 

no longer loose.

 

7Reset the lamp timer.

See the lamp’s manual for instructions on resetting the lamp timer.

Notes and Precautions

Press thebutton twice to display (a rough guide) the time of lamp use, the Lamp time item, in the Status display menu. p.33

It is recommended that the lamp be replaced after 2,000 hours of use. When Lamp time

reaches 2,000 hours, the icon and a message will appear. This display disappears when you pressbutton.

Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the lamp may fail to come on p.41 , and the lamp’s lifetime may be shortened.

Always replace the lamp with a new one.

The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.)

Maintenance

38

39

Image 20
Contents Others Maintenance Operations Preparations Before Using TDP-T91XGA/ With Document CameraSafety Precautions UsingBefore USA onlyImportant Safety Instructions Before UsingImportant Safety Instructions Power Supply Cord Selection Important PrecautionsPlace and Manner of Installation Save Original Packing MaterialsOther Cautions and Informations Remote Control BatteriesExemption Clauses Contents Checking the package contents Names of each part on the main unitComponent video signal Y/PB/PR from video Parts on the rear panel14 13 EquipmentPreparing and using the remote control Loading dry-cell batteries Into the remote controlOperating the remote control Names of each part on the document camera TDP-T91Placement Placement StylesConnection Before connectionTurning the power on and off OperationsBasic operations Correcting the keystone distortion Using handy featuresUsing auto setting Using the menus Using handy featuresHow to use the menus Cutting off the picture and sound temporarily MuteDisplay setting menu Using the menuImage adjustment menu Default setting menu No signalPower on Displaying Information Status displayUsing the document camera How to use the document cameraLocking the white balance Using the document cameraImage projection with the document camera About lamp Lamp replacementMaintenance Trouble indications Lens and main unit cleaningLamp replacement Before calling service personnel OthersSpecifications List of general specificationsDocument camera specifications TDP-T91 List of supported signals RGB signalsSpecifications List of supported signals Y/PB/PR signalsList of supported signals Video, S-Video signals Separately sold product