5.4 Self Test Print

 

 

 

 

Duty check print test (Receipt)

This option let you run duty check printing test. The printer prints the 12.5%, 25%, 50% and 100% duty original pattern. When Duty Check Print (Rcpt) is selected, printer prints the following menu. After selection of the printing side, test print will start.

Press the Paper Feed Button to start or stop the test.

Press the Paper Feed Button to continue or stop the test.

Duty Check Print

 

Stop and exit test

Short Click

Continue test

Long Click

00000008

5-10

Image 25
Contents TRST-A10 Series Cause electric shock Request Regarding Maintenance PrecautionsTable of Contents Product Overview FeaturesIntroduction TRST-A10 Applicable ModelPrinter SpecificationsDescription Mm PaperReceipt Roll Front/Rear View AppearanceLED and Feed Button Front ViewLED and Feed Button Problem What to Do Where to GoDC24V Socket connector ConnectorsSerial interface connector USB interface connectorRequirements for Operation SET UP ProcedureRS-232C cable pin configuration Strobe Setting up the Printer Installation Procedure Connecting the Power Cord and Interface Cable Interface cable Drawer interface connector 6-pin modular connector Connecting the DrawerGround terminal 6-pin modular connector Loading the Receipt Roll Raised Exit Self Test PrintRolling Ascii print test Receipt Print test Receipt Self Test PrintDuty check print test Receipt Print current setting Current Setting FormCleaning General MaintenanceCleaning the Print Head and Platen Removing Jammed Paper Problem Check Point Solution TroubleshootingWaste Recycling information for users Informazioni sul riciclo del prodotto
Related manuals
Manual 32 pages 36.75 Kb