Toshiba Model: GD-1150 Flag, Maintains the synchroniza 7E H Tion, Receives an NSF sent from

Page 54

-Control channel

The conventional T.30 procedure is performed. The transmission rate is 1200 bps.

Transmitter

Signal name

Abbreviation

Function

Remarks

 

 

 

 

Flag

flags

Maintains the synchroniza-

7E (H)

 

 

tion.

 

 

 

 

 

Non-standard facilities

NSS

Receives an NSF sent from

 

setting

 

the receiver. It selects the

 

 

 

available mode from the

 

 

 

received NSF, and specifies

 

 

 

the mode for the reception.

 

 

 

 

 

Transmitting Subscriber

TSI

Informs the telephone number

 

ID

 

of the transmitter.

 

 

 

 

 

Digital Command Signal

DCS

Specifies the mode that can

 

 

 

be used for the communica-

 

 

 

tion.

 

 

 

 

 

-

1

Declares to switch to the high-

“1” is sent continuously.

 

 

speed procedure.

 

 

 

 

 

Receiver

Signal name

Abbreviation

Function

Remarks

 

 

 

 

Non-Standard Facilities

NSF

Informs the presence of the

 

 

 

facilities other than those rec-

 

 

 

ommended by ITU-T, abbrevi-

 

 

 

ated user names, and

 

 

 

manufacturer codes, etc.

 

 

 

 

 

Called Subscriber ID

CSI

Informs the telephone number

 

 

 

of the receiver.

 

 

 

 

 

Digital Identification Signal

DIS

Informs the standard facilities

 

 

 

recommended by ITU-T.

 

 

 

 

 

Flag

flags

Maintains the synchroniza-

7E (H)

 

 

tion.

 

 

 

 

 

Confirmation for Recep-

CFR

Informs that the training of the

 

tion

 

modem is completed, and the

 

 

 

receiver is ready to receive

 

 

 

the image signal.

 

 

 

 

 

Reference: In the control channel, the frequency of the signals to be sent is different between the transmission and reception. The signal echoed back has never been misidentified as a signal sent from the other side. Therefore, this channel is not influenced by signals echoed back.\

GD-1150/1151/1200/1201/1160/1260

© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved

DIALING/COMMUNICATION CONTROL

 

3 - 18

Image 54
Contents GD-1150/1151/1200/1201/1160/1260 Trademarks Model Weight Number of people STUDIO3511/4511STUDIO281c/351c/451c Service of Machines Precautions against Static Electricity Page Contents 2003 2008 Toshiba TEC Corporation All rights reserved FAX Options FAX unit 2nd line for FAX boardSpecifications Original sizeFolio Embedded DBm to -8 dBm The setting can be changed by 1 dBTransmission system DBm to 0 dBm Level -55 dBm or lower cannot be detectedDimension width x length Printing area CompFeatures Specifications and Outline of System Accessories and Parts Following accessories and parts come with the FAX unitQty STUDIO281c/351c/451c OptionsSTUDIO230/280 Option Function ModelSTUDIO352/353/452/453 STUDIO202L/203L/232/233/282/283 seriesGD-1260NA/TW/EU/C System List GD-1150NA/TW/EU AU/AS/CGD-1150NA/TW/EU Bridge Kit KN-3511 FAX Board GD-1200 Finisher Hanging type e-STUDIO352/353 only MJ-1022 GD-1150NA/TW/EU AU/AS/C/KR Units and Components FAX MDM NCU Symbol Name Function RemarksLayout of PC Boards FAXMDM FAX FAX PWR NCU FAX power board Supplies the power -12V, +24VSTUDIO281c/351c/451c, e-STUDIO352/353/452/453 FAX control board Controls the FAX functionSpecifications and Outline of System Recording Mode LSU-RELATED FunctionsRecording Paper Selection Algorithm and Printing Algorithm Recording paper selection algorithmPrinting algorithm ST against A3/B4/A4/LD/LT size originals respectively Effective printing length Discard function Length of B Discard parameter Set valueOFF B4, A3 A4, B4 B5, B4 A5, A4 A5 , Comp LT, Comp COMP, LD LG/LT, LD ST, Folio B5, FolioSetting for the split recording Recording Paper and Function Table of the recording paper selection modes OthersPriority Receiving FAX document, or by Energy Saver ModeUser Functions Energy SaverMemory Reception YES Circuit Connection and Procedure to Change ModeDial call-up transmission to a telephone circuit Standby stateCommunication mode Toshiba original procedure Selection of the communication modeProcedure to select the transmission mode Telephone circuitThis signal can be sent manually Signal form Signaling System Diagram and Signal FormsCircuit control signals Signal name Signal formCommunication with the binary signals Mode change possible Informing that there is the next Image signalMode change is possible only for the original set manually ReceiverOnly error frame retransmitted 1 completed 2 completed Frames received Error occurredCFR JOB Status button Cancel buttonCED Nsfcsidis MCFBinary signals PRI-EOM PIPPIN PRI-MPSWhen this frame is the last frame, X = FCF FIF FCSFormat FCF format of each binary signal Binary signal Format9600 bps, 7200 bps 4800 bps, 2400 bpsTCF 3 V.8/V.34 communication sequence Standard procedure Transmitter Receiver Line closedSignal name Abbreviation Function Remarks 150 Hz Tone signal betweenHz and 3,750 Hz in units Data transmissionTRN ALTReceives an NSF sent from FlagMaintains the synchroniza 7E H Tion TransmitterIs completed Image data Image data are sent. TransmitterScrambled data frame to be Encoded image data Turn off Scrambled 1 is sent forTransmission of one Is completed Flag Short training SignalPPS-EOP Informs to disconnect the lineLine closed DIS cannot be recognized DIALING/COMMUNICATION Control DIALING/COMMUNICATION Control DIALING/COMMUNICATION Control DIALING/COMMUNICATION Control FAX mode FAX Automatic SwitchingTEL mode General functionsConfiguration Electrical CircuitsFAX PWR STUDIO202L/203L/232/233/282/283 GD-1151 GD-1260 95C265 4Mbit x MN86064 Configuration Description of CircuitsEU/AU/AS/C models CML1 Line path switching control circuitSignal Name Type Active Description Destination ATT3DB1RLY3, IC3 IC3IC5 Line 1 Dial Pulse Generation Signal Q53 Dial pulse generation circuitLine 1 Dial Pulse Generation Signal Line current detection circuit Line Current Detection Signal IC29 IC26Line Reverse Current Detection Signal IC29 IC26 REVA1Line 1 Current Detection Signal IC29 IC26 Current Reverse Line 1 Current Detection IC29 IC26 SignalLine 1 CI Detect Signal IC29 IC26 CI detection circuitLine 1 CI Detection Signal IC29 IC26 Line monitor circuit NCU board Line1Line Monitor Monitoring signalRinger/Alarm LOW HighRelation between the signals and sound volume is as follows Sound volumePC Boards PWA-F-FAX-562 / PWA-F-FAX-610PWA-F-FAX-670 PWA-F-NCU-US-562/PWA-F-NCU-631-US PWA-F-NCU-EU-562/PWA-F-NCU-631-EU PWA-F-MDM-563PWA-F-FAX-POWER-610 PWA-F-MDM-631PWA-F-FAX-POWER-631 Electrical Circuits Installation Explanation to the UsersInstallation