Dell T320 owner manual CPU0702 Message, CPU0703 Message, CPU0704 Message

Page 153

Error Code

Message Information

2.Turn off the system and remove input power for one minute.

3.Ensure the processor is seated correctly.

4.Reapply input power and turn on the system.

5.If the issue persists, see Getting Help.

CPU0702

Message

CPU bus parity error detected.

 

 

LCD Message

CPU bus parity error detected. Power cycle system.

 

Details

System event log and operating system logs may indicate that the

 

 

exception is external to the processor.

 

Action

1.

Check system and operating system logs for exceptions. If no

 

 

 

 

 

exceptions are found, continue.

 

 

2.

Turn off the system and remove input power for one minute.

 

 

3.

Ensure the processor is seated correctly.

 

 

4.

Reapply input power and turn on the system.

 

 

5.

If the issue persists, see Getting Help.

CPU0703

Message

CPU bus initialization error detected.

 

 

LCD Message

CPU bus initialization error detected. Power cycle system.

 

Details

System event log and operating system logs may indicate that the

 

 

exception is external to the processor.

 

Action

1.

Check system and operating system logs for exceptions. If no

 

 

 

 

 

exceptions are found, continue.

 

 

2.

Turn off the system and remove input power for one minute.

 

 

3.

Ensure the processor is seated correctly.

 

 

4.

Reapply input power and turn on the system.

 

 

5.

If the issue persists, see Getting Help.

CPU0704

Message

CPU <number> machine check error detected.

 

 

LCD Message

CPU <number> machine check error detected. Power cycle system.

 

Details

System event log and operating system logs may indicate that the

 

 

exception is external to the processor.

 

Action

1.

Check system and operating system logs for exceptions. If no

 

 

 

 

 

exceptions are found, continue.

 

 

2.

Turn off the system and remove input power for one minute.

 

 

3.

Ensure the processor is seated correctly.

 

 

4.

Reapply input power and turn on the system.

153

Image 153
Contents Regulatory Model E20S Series Regulatory Type E20S001 Dell Inc. All Rights Reserved Contents Using The Boot Manager Navigation Keys Installing System ComponentsInstalling The Hard-Drive Backplane Troubleshooting Your System Converting The System From Tower Mode To Rack ModeJumpers And Connectors Using System DiagnosticsTechnical Specifications System Messages167 About Your System Front-Panel Features And Indicators-Tower ModePage Interface ACPI-compliant operating systems Indicator, Button, or Icon Description ConnectorOne optional Sata DVD-ROM drive or DVD+/-RW drive To the system is turned off Front-Panel Features and Indicators Front-Panel Features And Indicators-Rack ModeLCD Panel Features Set error Setup MenuHome Screen Button DescriptionView Menu Diagnostic IndicatorsHard-drive Indicator Condition Electrical Indicator ConditionMemory Indicator Corrective Action PCIe Indicator Condition Hard-Drive Indicator PatternsError Drive-Status Condition Indicator Pattern RAID OnlySeconds Back-Panel Features And IndicatorsPower supply Redundant powerSupply Non-redundantNIC Indicator Codes Power Indicator Codes For Redundant Power SupplyGreen Link indicator is Power Indicator Codes For Non-Redundant Power Supply Other Information You May Need Keystroke Description Choosing The System Boot ModeF10 F11 F12Entering System Setup Responding To Error MessagesUsing The System Setup Navigation Keys System Setup Main Screen System Setup OptionsSystem Bios Screen System Information ScreenProcessor Settings Screen Memory Settings ScreenPrefetcher option is set to Enabled Option is set to EnabledExecute Disable Execute Disable option is set to EnabledBoot Settings Screen Sata Settings ScreenSerial Communications Screen Integrated Devices ScreenSystem Profile Settings Screen System Security Screen Miscellaneous Settings System And Setup Password FeaturesAssigning a System And/Or Setup Password Entering The Uefi Boot Manager Using Your System Password To Secure Your SystemOperating With a Setup Password Enabled Boot Manager Screen Using The Boot Manager Navigation KeysUefi Boot Menu IDRAC Settings UtilityEntering The iDRAC Settings Utility Changing The Thermal SettingsPage Page Installing The Front Bezel Recommended ToolsFront Bezel Optional Removing The Front Bezel System Feet-Tower ModeWheel Assembly Optional-Tower Mode Installing The System FeetRemoving The System Feet Removing and Installing the Wheel Assembly Removing The Wheel AssemblyInstalling The Wheel Assembly Opening And Closing The SystemOpening The System Closing The System Inside The SystemPower interposer board System feet PCIe card holder optional Slot Sata optical drive or PowerVault RD1000 Optical Drives And Tape Drives OptionalSlot SAS tape drive or blank Removing The Optical Drive Or Tape Drive Optical drive Tape drive Release latch Connector for power cable extension Installing The Optical Drive Or Tape Drive Cooling ShroudRemoving The Cooling Shroud Removing and Installing the Cooling Shroud Installing The Cooling ShroudRemoving a Hot-Swap Hard Drive Hard Drives-Hot-SwappableRemoving and Installing a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveInstalling a 2.5 Inch Hard-Drive Blank Removing a 2.5 Inch Hard-Drive BlankRemoving a 3.5 Inch Hard-Drive Blank Removing and Installing a 3.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive BlankScrews Inch hard-drive adapter Inch hard drive Hard Drives-Cabled Removing The Internal Hard-Drive Bay Installing and Removing the Internal Hard-Drive BayRemoving a Cabled Hard Drive Installing The Internal Hard-Drive BayRemoving and Installing a Cabled Hard Drive Installing a Cabled Hard DriveRemoving The Hard-Drive Backplane Hard-Drive BackplaneX8 hard-drive backplane Release pin Hooks SAS B connector Power connector X16 hard-drive backplane Release pin Hooks Backplane power connector Primary SAS connectors a and B Cabling-x16 Hard-Drive Backplane With Expansion Card Installing The Hard-Drive BackplaneRemoving a Four-Slot Hard-Drive Blank Four-Slot Hard-Drive BlankSystem Memory Installing a Four-Slot Hard-Drive BlankMemory Socket Locations 1333, 1066, Dual rankMode-Specific Guidelines General Memory Module Installation GuidelinesSample Memory Configurations Dimm Size in GB Number of DIMMs Dimm RankOrganization, Removing Memory Modules Ejecting The Memory Module Installing Memory ModulesInstalling The Memory Module Removing The Internal Cooling Fan Cooling FansFAN1 power connector on system board Removing The External Cooling Fan Installing The Internal Cooling FanBack of the system chassis Upper hook Lower hooks Internal USB Memory Key Optional Installing The External Cooling FanReplacing the Internal USB Key Replacing The Internal USB KeyRemoving The PCIe Card Holder PCIe Card Holder OptionalExpansion Card Installation Guidelines Installing The PCIe Card HolderExpansion Cards Expansion Card SlotGPU Card Installation Guidelines Removing An Expansion CardCard Priority Card Type Slot Priority Maximum Allowed Removing and Installing the Expansion Card Installing An Expansion CardRemoving a GPU Card Removing and Installing the GPU Card Installing a GPU CardRemoving The iDRAC Ports Card IDRAC Ports CardRemoving and Installing the iDRAC Ports Card Installing The iDRAC Ports CardInternal Dual SD Module Replacing An SD vFlash CardRemoving An Internal Dual SD Module Removing and Installing the Internal Dual SD Module Installing An Internal Dual SD ModuleInstalling An Internal SD Card Internal SD CardRemoving An Internal SD Card Removing a Processor ProcessorsRemoving and Installing the Heat Sink Removing and Installing a Processor Installing a ProcessorRemoving a Redundant AC Power Supply Redundant AC Power SupplyRemoving and Installing a Redundant AC Power Supply Installing a Redundant AC Power SupplyInstalling The Power Supply Blank Removing The Power Supply BlankRemoving and Installing the Power-Supply Divider Replacing The Power Supply DividerRemoving a Non-Redundant AC Power Supply Non-Redundant AC Power SupplyPower supply unit cage Power Distribution Board And Power Interposer Board Installing a Non-Redundant AC Power SupplyRemoving The Power Interposer Board Release latch Screws P6 cable connector 105 Installing The Power Interposer Board System BatteryReplacing The Power Distribution Board Replacing The System BatteryRemoving and Installing the System Battery Control-Panel AssemblyRemoving The Control-Panel Assembly Control-panel assembly cable connector Control panel Screw Information tag Tabs 110 Removing The Control Panel Installing The Control-Panel AssemblyControl-panel board Tabs LCD module Installing The Control Panel LCD ZIF cable Screws LCD module ZIF connector Control-panel board Screws Control-panel assembly 115 Removing The LCD Module Removing and Installing the LCD Module Installing The LCD ModuleRemoving and Installing the VGA Module Removing The VGA Module-Rack ModeInstalling The VGA Module-Rack Mode System BoardRemoving The System Board Removing the System Board Installing The System BoardPage 122 Safety Instructions Converting The System From Tower Mode To Rack ModeRemoving and Installing The System Top Cover Removing and Installing the Rack Ears Rack Installation126 Troubleshooting External Connections Troubleshooting The Video SubsystemTroubleshooting a USB Device Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting a Non-Redundant Power Supply Troubleshooting The System BatteryTroubleshooting Cooling Problems Troubleshooting Redundant Power SuppliesTroubleshooting Cooling Fans Troubleshooting System MemoryTroubleshooting An Internal USB Key Troubleshooting An Optical Or Tape Drive Troubleshooting An SD CardTroubleshooting Expansion Cards Troubleshooting a Hard DriveTroubleshooting Processor 136 Dell Online Diagnostics Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsRunning The Embedded System Diagnostics Least one event description is recorded System Diagnostic ControlsJumper System Board Jumper SettingsConnector Description System Board ConnectorsIntrusion Disabling a Forgotten PasswordPage Expansion Bus ProcessorExpansion slots MemoryConnectors Back DrivesFront Expanded Operating Temperature ConnectorsInternal VideoTemperature Continuous Operation Environmental TemperatureRelative Humidity Maximum VibrationGaseous Contamination Environmental148 LCD Messages System Error MessagesViewing LCD Messages Removing LCD MessagesAMP0302 Message Error CodeDetails ActionBAT0002 Message ASR0003 MessageBAT0017 Message CPU0000 MessageCPU0023 Message CPU0010 MessageCPU0204 Message CPU0700 MessageCPU0702 Message CPU0703 MessageCPU0704 Message Action Reinstall or reconnect the hardware HWC2003 Message If the issue persists, see Getting HelpFAN0000 Message Details Fan operating speed is out of range ActionMEM0001 Message MEM0000 MessageMEM0007 Message MEM0701 MessageMEM8000 Message MEM1208 MessagePCI1302 Message PCI1304 MessagePCI1342 Message PCI1320 MessagePCI1348 Message PCI1360 MessagePST0129 Message PST0128 MessagePSU0001 Message PSU0002 MessagePSU0016 Message PSU0006 MessagePSU0031 Message PSU0032 MessagePSU0035 Message PSU0034 MessagePSU0036 Message PSU0037 MessageSystem power inventory change PSU1201 Message Power supply redundancy is lost DetailsConfiguration and power consumption System power consumptionRFM1201 Message RFM1014 MessageRFM2001 Message RFM2002 MessageAppear if the user disabled event logging SEL0006 Message All event logging is disabled DetailsPower. If problem persists call support Security may be compromisedFailed Issues persists, contact supportFailures TMP0121 MessageAlert Messages Diagnostic Messages166 Contacting Dell Getting Help
Related manuals
Manual 9 pages 13.91 Kb Manual 169 pages 41.77 Kb

T320 specifications

The Dell PowerEdge T320 is a versatile tower server designed to meet the needs of small to medium-sized businesses. It is engineered to handle a variety of workloads, from data storage and virtualization to basic web serving and productivity applications. With a blend of performance, reliability, and expandability, the T320 serves as a robust solution for organizations looking to enhance their IT infrastructure.

One of the standout features of the T320 is its use of Intel's Xeon E5-2400 series processors, which deliver outstanding computing power and efficiency. Supporting up to two processors, this tower server can be configured to handle demanding tasks effectively. The ability to support up to 768GB of DDR3 memory through its 12 DIMM slots ensures that the T320 can manage memory-intensive applications, making it well-suited for data analytics and virtualization.

Storage capacity is another significant advantage of the T320. It comes equipped with up to eight 3.5-inch drives, which can be configured for RAID to enhance data protection and performance. The server supports both SATA and SAS drives, allowing for a range of options when it comes to speed and capacity. Additionally, a built-in PERC controller facilitates RAID configuration and monitoring, providing an additional layer of security for critical data.

The T320's design focuses on scalability, featuring several expansion slots for PCIe add-in cards. This allows businesses to grow their server capabilities over time, adding components such as graphics cards or network interface cards as needed. Furthermore, the server includes integrated 1GB Ethernet ports, facilitating easy connectivity within a network.

In terms of management and monitoring, the Dell PowerEdge T320 features the integrated Dell Remote Access Controller (iDRAC), which provides out-of-band management capabilities. This allows IT administrators to remotely manage and monitor server health and performance, reducing the need for physical access and streamlining maintenance tasks.

Moreover, the T320 emphasizes energy efficiency. With Dell's Energy Smart technologies, the server is designed to minimize power consumption and heat production while maintaining high performance. This not only contributes to lower operational costs but also supports environmentally friendly practices.

Overall, the Dell PowerEdge T320 is an efficient and reliable tower server that provides businesses with the performance and flexibility needed to manage various workloads. Its robust features, combined with Dell's commitment to quality and service, make it a valuable asset for companies looking to improve their IT operations.