Dell
990
service manual
Regulatory Model D05D Regulatory Type D05D001
Troubleshooting
Specs
Install
Error messages
Memory allocation error
No timer tick interrupt
Maintenance
System Configuration
Power Button Problem
Reset failed
Page 1
Dell OptiPlex 990 Desktop Service Manual
Regulatory Model: D05D
Regulatory Type: D05D001
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
Regulatory Model D05D Regulatory Type D05D001
Page
Contents
Coin-Cell Battery
Chassis Intrusion Switch
Power-Switch Cable
Speaker
Power Supply Unit PSU Thermal Sensor
Power Supply
System Setup
Troubleshooting
No timer tick interrupt
Memory allocation error
Decreasing available memory
Diskette read failure
Contacting Dell
Specifications
Page
Before Working Inside Your Computer
Working on Your Computer
Turning Off Your Computer
Recommended Tools
After Working Inside Your Computer
Page
Cover
Installing The Cover
Removing the Cover
Follow the procedures in After Working Inside Your Computer
Removing the Front Bezel
Front Bezel
Installing The Front Bezel
Removing the Expansion Card
Cards
Page
Installing The Expansion Card
Page
Removing the Optical Drive
Optical Drive
Installing The Optical Drive
Removing the Hard Drive
Hard Drive
Page
Installing The Hard Drive
Page
Removing the Memory
Memory
Installing The Memory
Removing the Chassis Intrusion Switch
Chassis Intrusion Switch
Installing The Chassis Intrusion Switch
Removing The Speaker
Speaker
Installing The Speaker
Removing The Heat Sink and Processor
Heat Sink
Page
Installing The Heat Sink and Processor
Page
Removing The Coin-Cell Battery
Coin-Cell Battery
Installing The Coin-Cell Battery
Removing The Power-Switch Cable
Power-Switch Cable
Installing The Power-Switch Cable
Removing The Front Thermal Sensor
Front Thermal Sensor
Installing The Front Thermal Sensor
Removing The System Fan
Chassis Fan
Installing The System Fan
Follow the procedures in After Working Inside Your Computer
Page
Removing The Input/Output Panel
Input/Output Panel
Remove the Input/Output panel
Installing The Input/Output Panel
Removing The Power Supply
Power Supply
Page
Lift the power supply out of the computer
Installing The Power Supply
Page
Removing The System Board
System Board
Installing The System Board
Follow the procedures in After Working Inside Your Computer
Page
Removing The PSU Thermal Sensor
Power Supply Unit PSU Thermal Sensor
Installing The PSU Thermal Sensor
System Setup
System Setup
Boot Menu
Boot Menu Enhancements
Timing Key Sequences
System Setup Options
Beep Codes and Text Error Messages
Navigation
SATA-2, SATA-3, and LOM MAC Address
Technology
System Configuration
Security
Video
Allow Non-Admin Password Changes This option is
Performance
Protector or if Auto Power is set to disabled
Power Management
Post Behavior
Enable F12 Boot menu enabled by default
Virtualization Support
Maintenance
Image Server
Address is
255.255.255.255
Setting is
System Logs
Clear Log
Displays the Bios Progress event log
Page
Diagnostic LEDs
Troubleshooting
Diagnostic Light Patterns
Power Button Problem
Steps
Power Button
Power Button Problem Description
LED
Troubleshooting Steps Re-seat the processor
If the problem persists, the system board is faulty
Troubleshooting Steps
Possible expansion card failure has occurred
Your computer
Code1-1-2
Beep Codes
Code Cause
Cause
Code Cause DMA page register read/write failure Through
Code
Cause Keyboard Controller Test failure Code
Address mark not found
Error Messages
Code Cause Cache test failure
Bad command or file name
Alert! Security override Jumper is installed
Bad error-correction code ECC on disk read
Data error
Hard-disk drive configuration error
Diskette subsystem reset failed
Decreasing available memory
Diskette drive 0 seek failure
Invalid Memory configuration, please populate DIMM1
Invalid configuration information-please run Setup program
Hard-disk drive controller failure
Hard-disk drive failure
Memory size in Cmos invalid
Memory allocation error
No boot sector on hard-disk drive
No boot device available
No timer tick interrupt
Non-system disk or disk error
Reset failed
Read fault
Seek error
Requested sector not found
Timer chip counter 2 failed
Time-of-day not set-please run the System Setup program
Unexpected interrupt in protected mode
Write fault
\ is not accessible. The device is not ready
Write fault on selected drive
Page
Technical Specifications
Specifications
Processor
Type
Network
Audio
System Information
Expansion Bus
PCI
Drives
External Connectors
System Board Connectors
Connector
Factor Back Panel Ultra Small Form Factor Front Panel Video
Vary based on the graphics card
Small Form Factor Ultra Small Form Factor
Controls and Lights
System power supply
Power system by
Turned on and is functional.
Outlet
Physical Height Width Depth Weight
Power Wattage Maximum Voltage Heat Dissipation
Environmental
Airborne contaminant level
Storage Grms Maximum shock Operating 40 G 105 G Altitude
S71.04-1985
102
Contacting Dell
Contacting Dell
Visit support.dell.com
Related pages
Troubleshooting Problem Look for for Blodgett KLS-40G, KLS-60G
Respiration Performance Specifications for Philips MP60/70/80/90
VIERA Link function does not work and an error message appears for Panasonic TH-L32X50M
Electrical Logic Schematic 27HP Kohler for Exmark 4500-497
When there is paper inside the printer for Olympus P-400
Installation for Intel IMB200VG
Parts List for Yamaha AEX502
TV Brand Code List for Samsung 20060814151350437
Chargethebattery for Canon 220 HS
Appendix a Safety Information for 3Com DUA1770-0AAA04
How do I learn about the warranty in the
Panasonic DVD S500 manual
?
Top
Page
Image
Contents