Furman Sound PST-10D owner manual Mounting, Protection OK Indicator

Page 8

voltage in excess of 137VAC is sensed, either on initial power-up or during normal operation, the PST-10D will shut off power and this indicator will light.

NOTE: If the mains power is above the high cutoff voltage and has caused the unit to remove power from its outlets, it can not restore power without the operator manually turning the unit off, then on again. Avoid turning the unit back on without first checking the source of the problem and perhaps changing the AC source.

Protection OK Indicator

Although the Furman SMP+ circuit assures virtually maintenance- free protection from transient voltage spikes and surges, nature has a way of occasionally creating electrical forces that are beyond the capabilities of any transient voltage surge suppressor device to absorb without some degree of damage. In the rare instance that this occurs, the blue “Protection OK” LED indicator will turn off. If this happens, some level of protection from voltage surges will remain, but Furman’s clamping voltage rating will be compromised. The unit must be returned to Furman Sound or an authorized Furman Service center for repair.

Mounting

If the Power Station needs to be mounted to the inside panel of a rack or hung from a wall, a convenient crossed oval cutout is provided on the unit’s bottom panel. A standard No. 6 pan head screw can be used in the same way a picture is hung from a wall. Simply measure the centers on the bottom of your Power Station. This will be the

8

Image 8
Contents PST-10D Safety Information IntroductionImportant Safety Instructions Operation Digital Video OutletsDelayed AC Outlets Trigger Switch and 12VDC inlet Page Circuit Breaker IndicatorsExtreme Voltage Shutdown Indicator Protection OK Indicator MountingWarranty Page Page Service