APC PMF3S-A, PMP4DS-A, PMP3S-A, PML3DS-A, PML4S-A, PMP4S-A Loss of Surge Protection, This material

Page 3

APC MODULAR PANEL PRODUCTS Surge Protective Device (SPD)

WARNINGS

CAUTION

LOSS OF SURGE PROTECTION

·During installation into an electrical system, SPD’s must not be energized until the electrical system is completely installed, inspected, and tested. All conductors must be connected and functional, including the neutral. The voltage rating of the device and system must always be verified before energizing the surge protective device.

·Any factory or on-site testing of power distribution equipment that exceeds the normal operating voltage, such as high-potential insulation testing, or any other tests where the suppression components will be subjected to voltages higher than their rated turn-on voltage must be performed with the suppressor disconnected from the power source. The neutral connection at the SPD must also be disconnected prior to performing high-potential testing and then reconnected upon completion of the test.

Failure to follow these instructions can result in loss of power or loss of surge protection that can cause injury or equipment damage.

IMPORTANT!

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by APC for any consequences arising out of the use of

this material.

3

Image 3
Contents Surge Protective Devices SPD Hazard of Electric SHOCK, EXPLOSION, or ARC Flash Loss of Branch Circuit Power and Surge ProtectionThis material Loss of Surge ProtectionContents Testing IntroductionIntroduction Unpacking Preliminary Inspection Storage PackagingSafety Labels IdentificationSPD Location Considerations Voltage Rating Installation TorqueElectrical ElectricalIntegral Switch Location of SPD Undersized Wiring USE only Conductors Rated 30 a or GreaterInadequate Raceway Electrical Continuity System GroundingPatch Cables marked InstallationInstallation Danger Special Enclosure ConsiderationsFollow steps 1-5 to make wiring connections WiringSingle-Phase, 3-Wire, Grounded Wiring Diagrams Without Integral DisconnectChasis Ground Operation SPD Module LEDs Wye and Split Phase configurationsThree-Phase Display Panel with Surge Counter Dry Contact Configuration Maintenance Maintenance TroubleshootingPreventive Maintenance Troubleshooting Flowcharts TroubleshootingCustomer Support APC Worldwide Customer Support

PMP3DS-A, PMG3DS-A, PML3S-A, PMG4DS-A, PMF4S-A specifications

The APC PML3DS-A, PMP3S-A, PMP4S-A, PMG4S-A, and PMP4DS-A are part of a product line designed for power management and distribution in various applications, from data centers to industrial setups. Each model boasts unique features and technologies that cater to specific operational needs while prioritizing efficiency, reliability, and safety.

The APC PML3DS-A is a highly efficient power management solution suitable for small- to medium-sized enterprises. It features intelligent monitoring capabilities, allowing users to track power usage and optimize efficiency. The model integrates advanced surge protection technology, safeguarding equipment from voltage spikes. With a compact design, it offers flexibility in placement while still providing robust operational support.

The PMP3S-A model focuses on scalability, making it an excellent choice for businesses anticipating growth. This power management unit is compatible with multiple configurations, allowing seamless integration into existing systems. One of its standout features is the energy metering functionality, enabling precise tracking of energy consumption. This feature is invaluable for organizations seeking to reduce costs and improve sustainability initiatives.

Next in the lineup, the PMP4S-A offers enhanced power distribution capabilities, designed to handle higher loads. This unit is equipped with modular design elements, allowing for customization based on specific requirements. Additionally, it features real-time load balancing technology that ensures even distribution of power across connected devices, reducing the risk of overload and enhancing system stability.

The PMG4S-A stands out for its advanced management interface, providing users with a user-friendly experience. Its web-based management system allows remote monitoring and control, facilitating rapid response to any issues that arise. The PMG4S-A also includes built-in redundancy features, ensuring uninterrupted power supply and enhancing overall system resilience.

Lastly, the PMP4DS-A is engineered with advanced diagnostic capabilities, identifying potential issues before they can impact performance. This proactive approach to power management is crucial for maintaining operational integrity in critical systems. It also provides advanced communication options, integrating seamlessly with existing network infrastructure for improved management and reporting.

Together, these models from APC represent a comprehensive solution for power management, balancing performance, scalability, and safety across various applications. Their advanced features and technologies make them essential components for businesses looking to enhance their operational efficiency and reliability in power distribution.