Belkin F6H400ukUSB, F6H600ukUSB user manual Overview Side Panel, Overview Alarms, Overview Storage

Page 3

Overview Side Panel

1.AC Input Power Cord (See #1 on Fig. 1) Provides power to your Battery Backup.

2.AC Breaker (Circuit Breaker; see #2 on Fig. 1)

Should a power overload occur, the circuit breaker triggers the unit to turn off AC power. To restore power, press the “circuit breaker” button to reset, then press the “Power” button.

3

3. USB Communication Port (See #3 on Fig. 1)

The unit features a USB communication port. Installation of the cable and the Bulldog Plus Software, which allows the unit to connect to your computer, is optional. The unit will provide backup power whether or not the cable and software are installed; however, without them you will be unable to utilize the data management product features.

Overview Alarms

Backup (Slow Alarm)

When the unit is in “backup” mode (running on battery), the YELLOW LED illuminates and the unit emits an audible alarm. The alarm stops when the unit returns to normal online operation.

Low Battery (Rapid Alarm)

In “backup” mode, when the battery energy runs low, the unit beeps rapidly until it either shuts down from a depleted battery or returns to normal online operation.

Fault (Continuous Alarm)

When the unit fails, it emits an audible alarm continuously to warn of a fault condition. Disconnect the equipment prior to checking it.

Overview Storage

Storage Conditions

Store the unit covered and upright in a cool, dry location with its battery fully charged. Before storing, charge the unit for at least twelve

(12)hours.

Extended Storage

During extended storage in environments where the ambient temperature is -15 en +30 °C, charge the unit’s battery every six (6) months. During extended storage in environments where the ambient temperature is +30 en 45 °C, charge the unit’s battery every three (3) months.

Note:

Overview Technical Specifications

 

 

 

 

 

F6H400ukUSB

 

F6H600ukUSB

Model

 

 

 

 

F6H400exUSB

 

F6H600exUSB

 

 

 

 

 

F6H400evUSB

 

F6H600evUSB

Capacity

 

 

VA/W

 

400VA/200W

 

600VA/300W

 

 

 

Voltage

 

 

220/230/240VAC

Input

 

Frequency

 

 

 

50/60Hz

 

Max input current

 

 

 

5A

 

 

 

 

 

 

 

 

Phase

 

 

 

Single

 

 

Voltage Range

 

220/230/240VAC+10%

Output

 

Frequency

 

 

50Hz or 60Hz+1Hz

(inverter Mode)

 

Max output current

 

 

 

5A

 

 

Waveform

 

 

Modified Sinwave

Transfer Time

 

 

Typical

 

 

 

2-6ms

 

 

Battery Type

 

12V4.5Ahx1

 

12V5Ahx1

 

Backup Time at a PC load with monitor

6-11 Minutes

 

10-15 Minutes

Battery

 

(Typical 100W)

 

 

 

 

 

 

 

 

 

Recharging Time

 

 

16 hours max

 

 

 

(recharge up to 90% capacity)

 

 

 

 

 

Display

 

 

LED

 

Power on, Backup, Fault

 

 

Battery Mode

 

Sounding every 5 seconds

Audible Alarm

 

Low Battery

 

Sounding every second

 

Overload

 

Sounding every 0.5 second

 

 

 

 

 

 

Fault

 

Continuously Sounding

Protection

 

Full Protection

 

Overload, Overcharge, Modem/Phone Line Surge

 

 

Protection and Short Circuit Protection

 

 

 

 

 

 

 

Dimension (DxWxH)

 

352mm*134mm*86mm

Physical

 

Net Weight

 

 

 

2.9KG

 

Shucko

France

 

UK

4 sockets for surge protection with battery backup

Environment

 

Operation Temperature

 

 

0-40oC

 

Operation Humidity

 

 

0-90%

 

 

 

 

All specifications are subject to change without prior notice.

2- UK

Image 3
Contents Battery Backup with Surge Protection Introduction Package ContentsOverview Features and Functions Overview Important Safety InstructionsOverview Storage Overview AlarmsOverview Technical Specifications Overview Side PanelTrouble shooting InstallationImoprtant safety instructions Belkin Tech Support +44 0 1933 Battery Backup with Surge Protection