Trouble shooting

Symptom

Possible Causes

 

 

-Unswitched LED does not come on when the ACE-615 AC power cord is

-Outlet may be shut off at the main breaker box

plugged into an outlet

 

 

 

-Power button pushed in, but switched outlets are off and power LED glows

-Unit may be in standby mode

amber

-Remove any plug in the 12v trigger jack

 

 

-ACE-615 does not respond to 12v input

-Power button must be pressed in for remote activation

 

-The trigger voltage maybe outside the allowable + (5-12) volts

 

-

-No delay between accessories and amplifiers outlets

-Delay settings are incorrect. Return to authorized dealer for adjustment.

 

Factory settings are approximately ten seconds for amplifier turn-on and

 

thirty seconds for accessories turn-off.

 

 

Technical Specifications

Electrical

Input power

120VAC, +/-10%, 5-/60Hz

Protection

15A Circuit Breaker

Internal Power Consumption

Less than 5 watts

Control Input

+/-5V to 24V AC/DC

Total Output

15A

Environmental: Operating Temperature

0 to +50 C

Storage Temperature

-40 to +80 C

 

Filter

 

Noise: Normal Mode

-5dB at 5kHz; -38 dB at 300kHz

Common Mode

-3dB at 300kHz; -40 dB at 1 MHz

 

 

Surge Protection

 

Endurance

1,000 surges 6 kV; 3 kA

Clamping

172 volts

Response Time

0 sec.

(Passive protection / always on)

Maximum Applied Pulse (Combination Wave):

Voltage: 6,000 volts

Current: Unlimited due to current limiting

Joules: Unlimited due to current limiting

Mechanical

Dimensions....17”(430mm) x 12” (305mm) x 3.5”(89mm)

Weight

10 lbs. (2.7 kg)

AC Cord

6 ft. (1.8m)

Servicing

ADCOM has a technical service department to answer questions pertaining to the installation and operation of your unit. In the event of difficulty, please contact us for prompt advice. If your problem can not be resolved through our combined efforts, we may refer you to an authorized repair agency, or authorize return of the unit to the factory. To aid us in directing you to a convenient service station, please indicate which major city is accessible to your home.

Phone or Fax inquiries to:

Phone (732) 683-2356

Fax (732) 683-9790

Mon - Fri 9AM - 5PM EST

Please direct inquiries to:

ADCOM Service Department

Please include a return phone or fax number for the reply.

email and website info:

info@adcom.com www.adcom.com

Please include a return e-mail address for the reply.

Please address all mail inquires to: ADCOM Service Corporation

10 Timber Lane Marlboro, NJ 07746 USA

Please include a return address for the reply.

Image 4
Contents E 6 1 IntroductionInstallation Safety InstructionsConnections Front Panel Control OperationRemote 12v Trigger Control Trouble shooting