ADC Four-Pair Riser Cable manual Psnext

Page 3

5 / 0 8 • 1 0 4 9 7 6 A E   CopperTen® Four-Pair Riser Cable

TrueNet®

CopperTen® Four-Pair Riser Cable

 

Fitted

Insertion

 

 

 

 

 

 

Freq

Impedance

Loss

Return Loss

Pair-Pair Next

PSNEXT

(MHz)

(Ohms)

(dB/100m)

(dB/100m)

(dB/100m)

(dB/100m)

 

SPEC

Max

TIA Spec

Min

TIA Spec

Min

TIA Spec

Min

TIA Spec

 

 

 

 

 

 

 

 

 

 

1

100 ± 5

1.7

2.0

26.5

20.0

88.4

74.3

87.2

72.3

 

 

 

 

 

 

 

 

 

 

4

100 ± 3

3.4

3.7

31.1

23.0

82.8

65.3

80.0

63.3

 

 

 

 

 

 

 

 

 

 

8

100 ± 3

4.9

5.2

37.2

24.5

73.5

60.8

72.1

58.8

 

 

 

 

 

 

 

 

 

 

10

100 ± 3

5.5

5.9

30.3

25.0

73.9

59.3

71.7

57.3

 

 

 

 

 

 

 

 

 

 

16

100 ± 3

7.0

7.4

32.0

25.0

67.5

56.2

66.4

54.2

 

 

 

 

 

 

 

 

 

 

20

100 ± 3

7.8

8.3

35.2

25.0

70.0

54.8

68.5

52.8

 

 

 

 

 

 

 

 

 

 

25

100 ± 3

8.8

9.3

35.4

24.3

68.1

53.3

67.7

51.3

 

 

 

 

 

 

 

 

 

 

31.25

100 ± 3

9.9

10.4

38.9

23.6

67.4

51.9

64.7

49.9

 

 

 

 

 

 

 

 

 

 

62.5

100 ± 3

14.1

14.9

33.6

21.5

60.3

47.4

59.6

45.4

 

 

 

 

 

 

 

 

 

 

100

100 ± 3

18.0

19.0

28.1

20.1

59.2

44.3

57.8

42.3

 

 

 

 

 

 

 

 

 

 

155

100 ± 3

22.6

24.0

28.4

18.8

50.6

41.4

50.0

39.4

 

 

 

 

 

 

 

 

 

 

200

100 ± 3

25.8

27.5

27.3

18.0

52.5

39.8

51.4

37.8

 

 

 

 

 

 

 

 

 

 

250

100 ± 3

29.0

31.0

27.2

17.3

50.9

38.3

49.8

36.3

 

 

 

 

 

 

 

 

 

 

300

100 ± 3

31.8

34.2

25.0

16.8

46.9

37.1

46.4

35.1

 

 

 

 

 

 

 

 

 

 

350

100 ± 3

34.5

37.2

23.5

16.3

43.8

36.1

43.3

34.1

 

 

 

 

 

 

 

 

 

 

400

100 ± 3

37.0

40.0

24.5

15.9

47.2

35.3

44.7

33.3

 

 

 

 

 

 

 

 

 

 

450

100 ± 3

39.4

42.7

22.9

15.5

45.9

34.5

42.8

32.5

 

 

 

 

 

 

 

 

 

 

500

100 ± 3

41.6

45.3

21.3

15.2

48.2

33.8

47.0

31.8

 

 

 

 

 

 

 

 

 

 

550

100 ± 3

43.8

 

21.4

 

46.2

 

44.6

 

 

 

 

 

 

 

 

 

 

 

600

100 ± 3

45.9

 

21.2

 

44.2

 

43.0

 

 

 

 

 

 

 

 

 

 

 

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-10 specifications.

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

3

Image 3
Contents Spec Sheet Construction Characteristics Mechanical CharacteristicsElectrical Characteristics Psnext Pselfext Psacr

Four-Pair Riser Cable specifications

The ADC Four-Pair Riser Cable is an advanced networking solution designed to meet the increasing demands for high-speed data transmission within commercial and residential buildings. This cable is primarily utilized for vertical spaces, hence the term "riser." Its purpose is to connect different floors of a building, providing a reliable means of facilitating communication between network points.

One of the standout features of the ADC Four-Pair Riser Cable is its ability to support high-performance data transmission at speeds up to 1 Gbps and beyond. This capability is particularly crucial as organizations transition to bandwidth-intensive applications such as cloud computing, video conferencing, and streaming services. The cable is commonly compliant with Category 5e or Category 6 standards, ensuring superior performance and minimal signal degradation over long distances.

The cable's construction includes four twisted pairs of copper conductors, which significantly reduce electromagnetic interference (EMI) and crosstalk. The twisted pair design works by canceling out noise that may disrupt signal integrity, thus ensuring a more stable and reliable connection. Additionally, the cable is often encased in a fire-retardant jacket, meeting stringent safety standards and making it suitable for installation in riser shafts where fire safety is paramount.

Another notable characteristic of the ADC Four-Pair Riser Cable is its flexibility in installation. With a lightweight design, the cable can be easily routed through conduits and tight spaces, streamlining the installation process while allowing for future modifications and upgrades. The cable is typically available in various lengths, making it versatile for different architectural layouts.

Moreover, these cables are often designed to be compatible with a range of networking technologies, including Power over Ethernet (PoE). This feature enables the delivery of power and data through a single cable, simplifying networking by reducing the number of required installations.

In summary, the ADC Four-Pair Riser Cable stands out for its high-speed capabilities, reduced electromagnetic interference, fire retardance, and flexibility in installations. As businesses and devices become more interconnected, investing in reliable network infrastructure such as this cable is essential for maintaining performance and efficiency in data transmission systems.