Allied Telesis AR300 series manual ICM-BRI1, BRI0

Page 3

If the interface is not activated, the reason could be one of the following:

1.The interface has been put into NT mode.

On the AT-AR041 and AT-AR042 multi-BRI NSM modules it is possible to put the ISDN interface(s) into NT mode so that they can emulate a network switch interface. This can be useful for bench testing network configurations. To see which mode the ISDN interface is currently in, use the command:

show bri=n state

The first item in the output, Interface Type, will have either the value NT or the value TE. If the ISDN interface is in TE mode then it is set up correctly.

If the ISDN interface is in NT mode it is set up incorrectly, and it is a matter of changing a pair of jumpers on the circuit board to put the interface back into TE mode.

2.There is a physical fault in the router's ISDN interface circuitry.

The router is able to test its own interface. The steps to performing the self-test are: a Create a BRI loopback plug and insert it into the interface socket.

If the BRI interface under consideration is on an ICM card, it is not necessary to use a loopback plug, as the interface is capable of internal loopback, and so does not need external loopback.

bAt the command prompt, enter the command: enable test int=brin

where n is the number of the BRI interface under consideration. Interfaces are numbered from 0.

This initiates a 4-minute self-test.

cWait 4 minutes, until the router outputs a message to inform you that the self-test is complete.

Then enter the command: show test

which will output the test results as shown in the following figure.

Board ID Bay Nick Name Part Name Rev Serial number

------------------------------------------------------------------------

Base

47

3100

NIQ-3100

M2-0

9774202

IC Module

39

0 ICM-BRI1

EXP-0303

M1-2

8620690

 

 

 

Duration

 

Details

Interface

State

Result

Type (minutes) Data( %OK ) Control

------------------------------------------------------------------------

eth0

no test

-

-

-

-

-

-

port0

no test

-

-

-

-

-

-

port1

no test

-

-

-

-

-

-

port2

no test

-

-

-

-

-

-

port3

no test

-

-

-

-

-

-

BRI0

complete

good

-

4

good(100.0)

-

------------------------------------------------------------------------

If the Result column shows the result to be good, then the BRI interface has no physical faults (that the self-test can detect, anyway). If the result is anything other than good, then the interface is faulty and you need to contact your distributor regarding a repair.

3

Image 3
Contents Which products does it apply to? Related How To NotesYou also may find the following How To Notes useful IntroductionHow to troubleshoot Isdn InfoIsdn BRI0 ICM-BRI1TEI BRI0 Isdn SapiAlive Cleared OUT Are Isdn calls connecting successfully?Duration column Destination out of order LCP Starting Other tips for testing Isdn connectionsCommand to activate an Isdn call is YES Ipcp Closed