Installation
Safety and Installation
Information
[Needs to be checked and
•The Terminal should be installed and setup only by qualified personnel.
•Connect a fast 1.25A fuse to the incoming line for the positive supply voltage to protect the Terminal.
•If a power supply unit is used to supply the GM29 modem, it must meet the demands placed on SELV circuits in accordance with EN60950. When using batteries and accumulators, adhere to the relevant regulations.
•The maximum permissible connection length between the GM29 Modem and the supply source is 3m.
•Your supplier will be pleased to provide you with a detailed technical description and technical support for the GM29 Modem.
Securing the Modem
NOTE! Before securing the modem take into account the amount of additional space required for the mating connectors and cables that will be used in the application.
NOTE! Where access is restricted, it may be easier to connect all the cables to the modem prior to securing it in the application.
Securely attach the GM29 modem to the host application using two 3mm diameter
CAUTION! Do not over tighten the fixings screws. Excessive torque applied to the screws can crack the plastic case.
Fixing Screws
Installation 5