NOTE: Catalog listings in the order guides below do not include rocker operators. See ``How to Order.''

Application Note: Honeywell MICRO SWITCH does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. NR switches use silver cadmium oxide contacts. For other options, contact the MICRO SWITCH Application Center at 1-800-537-6945.

NR 2-POSITION FLUSH-PANEL MOUNT ROCKERS ORDER GUIDE

 

 

 

 

 

 

 

 

 

Circuits Made With Rocker At:

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

 

 

Elect.

Termination Style

 

of

Ident. Lug

Opposite Lug

UL Rating

Rating

 

 

 

Poles

Position

Position

Code

Code

Screw

Solder

Q-C

 

OFF

2-3

L191

1

1NR1-2

11NR1-2

1NR91-2

1

1-2

2-3

L191

1

1NR1-3

11NR1-3

1NR91-3

 

OFF*

2-3

L192

2

1NR1-4

11NR1-4

1NR91-4

 

1-2*

OFF

L192

2

1NR1-6

11NR1-6

1NR91-6

 

1-2*

2-3

L192

2

1NR1-8

11NR1-8

1NR91-8

 

 

 

 

 

 

 

 

 

OFF

2-3, 5-6

L191

3

2NR1-2

12NR1-2

2NR91-2

2

1-2, 4-5

2-3, 5-6

L191

3

2NR1-3

12NR1-3

2NR91-3

 

OFF*

2-3, 4-6

L192

4

2NR1-4

12NR1-4

2NR91-4

 

1-2, 4-5*

OFF

L192

4

2NR1-6

12NR1-6

2NR91-6

 

1-2, 4-5*

2-3, 4-6

L192

4

2NR1-8

12NR1-8

2NR91-8

 

 

 

 

 

 

 

 

 

OFF

2-3, 5-6, 8-9, 11-12

L191

5

4NR1-2

14NR1-2

4NR91-2

4

1-2, 4-5, 7-8, 10-11

2-3, 5-6, 8-9, 11-12

L191

5

4NR1-3

14NR1-3

4NR91-3

 

OFF*

2-3, 5-6, 8-9, 11-12

L192

6

4NR1-4

14NR1-4

4NR91-4

 

1-2, 4-5, 7-8, 10-11*

OFF

L192

6

4NR1-6

14NR1-6

4NR91-6

 

1-2, 4-5, 7-8, 10-11*

2-3, 5-6, 8-9, 11-12

L192

6

4NR1-8

14NR1-8

4NR91-8

 

 

 

 

 

 

 

 

NR 3-POSITION FLUSH-PANEL MOUNT ROCKERS ORDER GUIDE

 

 

 

 

 

 

 

 

 

 

Circuits Made With Toggle At:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

 

 

 

Elect.

Termination Style

 

of

Ident. Lug

Center

Opposite Lug

UL Rating

Rating

 

 

 

Poles

Position

Positon

Position

Code

Code

Screw

Solder

Q-C

 

 

 

 

 

 

 

 

 

 

1-2

OFF

2-3

L191

1

1NR1-1

11NR1-1

1NR91-1

1

1-2*

OFF

2-3

L192

2

1NR1-5

11NR1-5

1NR91-5

 

1-2*

OFF

2-3*

L192

2

1NR1-7

11NR1-7

1NR91-7

 

NONE**

OFF

2-3

L191

1

1NR1-21

11NR1-21

1NR91-21

 

NONE**

1-2

2-3

L191

1

1NR1-31

11NR1-31

1NR91-31

 

NONE**

1-2

2-3*

L192

2

1NR1-51

11NR1-51

1NR91-51

 

1-2*

OFF

NONE**

L192

2

1NR1-61

11NR1-61

1NR91-61

 

 

 

 

 

 

 

 

 

 

1-2, 4-5

OFF

2-3, 5-6

L191

3

2NR1-1

12NR1-1

2NR91-1

2

1-2, 4-5*

OFF

2-3, 5-6

L192

4

2NR1-5

12NR1-5

2NR91-5

 

1-2, 4-5*

OFF

2-3, 5-6*

L192

4

2NR1-7

12NR1-7

2NR91-7

 

NONE*

OFF

2-3, 5-6

L191

3

2NR1-21

12NR1-21

2NR91-21

 

NONE**

1-2, 4-5

2-3, 5-6

L191

3

2NR1-31

12NR1-31

2NR91-31

 

NONE**

1-2, 4-5

2-3, 5-6*

L192

4

2NR1-51

12NR1-51

2NR91-51

 

1-2, 4-5*

OFF

NONE**

L192

4

2NR1-61

12NR1-61

2NR91-61

 

1-2, 4-5

2-3, 4-5

2-3, 5-6

L191

3

2NR1-12

12NR1-12

2NR91-12

 

1-2, 4-5*

1-2, 5-6

2-3, 5-6

L192

4

2NR1-50

12NR1-50

2NR91-50

 

1-2, 4-5*

1-2, 5-6

2-3, 5-6*

L192

4

2NR1-70

12NR1-70

2NR91-70

 

 

 

 

 

 

 

 

 

 

1-2, 4-5, 7-8, 10-11

OFF

2-3, 5-6, 8-9, 11-12

L191

5

4NR1-1

14NR1-1

4NR91-1

4

1-2, 4-5, 7-8, 10-11*

OFF

2-3, 5-6, 8-9, 11-12

L192

6

4NR1-5

14NR1-5

4NR91-5

 

1-2, 4-5, 7-8, 10-11*

OFF

2-3, 5-6, 8-9, 11-12*

L192

6

4NR1-7

14NR1-7

4NR91-7

 

NONE*

OFF

2-3, 5-6, 8-9, 11-12

L191

5

4NR1-21

14NR1-21

4NR91-21

 

NONE**

1-2, 4-5, 7-8, 10-11

2-3, 5-6, 8-9, 11-12

L191

5

4NR1-31

14NR1-31

4NR91-31

 

NONE**

1-2, 4-5, 7-8, 10-11

2-3, 5-6, 8-9, 11-12*

L192

6

4NR1-51

14NR1-51

4NR91-51

 

1-2, 4-5, 7-8, 10-11*

OFF

NONE**

L192

6

4NR1-61

14NR1-61

4NR91-61

 

1-2, 4-5, 7-8, 10-11

2-3, 4-5, 7-8, 11-12

2-3, 5-6, 8-9, 11-12

L191

5

4NR1-12

14NR1-12

4NR91-12

 

1-2, 4-5, 7-8, 10-11*

2-3, 4-5, 7-8, 11-12

2-3, 5-6, 8-9, 11-12

L192

6

4NR1-50

14NR1-50

4NR91-50

 

1-2, 4-5, 7-8, 10-11*

2-3, 4-5

2-3, 5-6, 8-9, 11-12*

L192

6

4NR1-70

14NR1-70

4NR91-70

 

 

 

 

 

 

 

 

 

*These positions are momentary. All others are maintained.

**Toggle lever is blocked from these products. Toggle becomes 2-position, with center being one extreme position.

TERMINAL CIRCUIT IDENTIFICATION

Terminal identification numbers referenced in the order guides are molded into the switch base.

These numbers indicate which circuits are made in each rocker position (e.g. ``1-2''refers to circuit closure through terminals 1 and 2).

124

Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada

Image 2
Contents NR Series Manual SwitchesSealed Rocker Switches Terminal Circuit Identification NR 2-POSITION FLUSH-PANEL Mount Rockers Order GuideNR 3-POSITION FLUSH-PANEL Mount Rockers Order Guide Termination StyleTerminal Circuit Identification Seated Rocker SwitchesMounting Dimensions UL and CSA Electrical Ratings Flat Base Sealed Toggles and RockersNT/NR Series AmperesNT 2-POSITION Order Guide Mating Connectors Order GuideLocking Configurations NT 3-POSITION Order GuideElectrical Rating Flat Base Sealed RockersNR 2-POSITION Order Guide Rocker Buttons Order GuideFlat Base Sealed Toggles and Rockers Mounting Dimensions For reference onlyToggle Switches Rocker Switches, Above Panel 129