QuickSpecs
HP Compaq dc7700 Business PC
Technical Specifications
Unit Environment and Operating Conditions
Ultra-slim Desktop
Small Form Factor
Convertible Minitower
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow. Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.
Temperature Range | Operating: 50° to 95° F (10° to 35° C)* |
| |
Relative Humidity | Operating: 10% to 90% |
| |
Maximum Altitude | Operating: 10,000 ft (3048 m) |
(unpressurized) |
*NOTE: Operating temperature is
Power Supply |
| Small Form Factor | Convertible Minitower |
Power Supply | 200 watt custom power supply | 240 watt custom power supply | 365 watt custom power supply |
| – Active PFC) | – Active PFC | – Active PFC) |
Operating Voltage Range | 90 – 264 VAC | 90 – 264 VAC | 90 – 264 VAC |
Rated Voltage Range | 100 – 240 VAC | 100 – 240 VAC | 100 – 240 VAC |
Rated Line Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Operating Line Frequency | 47 – 63 Hz | 47 – 63 Hz | 47 – 63 Hz |
Range |
|
|
|
Rated Input Current | 4A | 5A | 6A |
System Heat Dissipation | Typical 340 btu/hr | Typical 340 btu/hr | Typical 375 btu/hr |
| (86 | (86 | (95 |
| Maximum 1050 btu/hr | Maximum 1260 btu/hr | Maximum 1916 btu/hr |
| (265 | (318 | (483 |
Power Supply Fan | 70mm variable speed | 80mm variable speed | 92mm variable speed |
Energy Star 3.0 Compliant | X | X | X |
Blue Angel Compliant | X | X | X |
(<5w in S5 – Power Off) |
|
|
|
FEMP Standby Power | X | X | X |
Compliant |
|
|
|
(<2W in S5 – Power Off)** |
|
|
|
Power Consumption in ES | < 3W | < 3W | < 3W |
Mode – Suspend to RAM (S3) |
|
|
|
(Instantly Available PC) |
|
|
|
Environmental and Mechanical |
| ||
Engineering Support Center |
|
|
|
(EMESC) – Intranet Web Site |
|
|
|
only |
|
|
|
**NOTE: Power consumption in the Off/Apparent Off mode is measured and reported with the network interface controller "Wake on LAN" feature disabled in F10 Setup (default is "enabled").
DA - 12543 Worldwide QuickSpecs — Version 3 — 9.28.2006 | Page 18 |