Error Message List
| Error Messages | FRU/Action in Sequence | 
| 
 | 
 | 
| 
 | DIMM | 
| 
 | System board | 
| 
 | 
 | 
| Device Address Conflict | Run “Load Default Settings” in BIOS Setup Utility. | 
| 
 | RTC battery | 
| 
 | System board | 
| 
 | 
 | 
| Allocation Error for device | Run “Load Default Settings” in BIOS Setup Utility. | 
| 
 | RTC battery | 
| 
 | System board | 
| 
 | 
 | 
| Failing Bits: nnnn | DIMM | 
| 
 | BIOS ROM | 
| 
 | System board | 
| 
 | 
 | 
| Fixed Disk n | None | 
| 
 | 
 | 
| Invalid System Configuration Data | BIOS ROM | 
| 
 | System board | 
| 
 | 
 | 
| I/O device IRQ conflict | Run “Load Default Settings” in BIOS Setup Utility. | 
| 
 | RTC battery | 
| 
 | System board | 
| 
 | 
 | 
| Operating system not found | Enter Setup and see if fixed disk and drive A: are properly | 
| 
 | identified. | 
| 
 | Diskette drive | 
| 
 | Hard disk drive | 
| 
 | System board | 
| 
 | 
 | 
| Error Message List | 
 | 
| No beep Error Messages | FRU/Action in Sequence | 
| 
 | 
 | 
| No beep,  | Power source (battery pack and power adapter). See “Power | 
| LCD is blank. | System Check” on page 91.. | 
| 
 | Ensure every connector is connected tightly and correctly. | 
| 
 | Reconnect the DIMM. | 
| 
 | LED board. | 
| 
 | System board. | 
| 
 | 
 | 
| No beep,  | Power source (battery pack and power adapter). See “Power | 
| LCD is blank. | System Check” on page 91.. | 
| 
 | Reconnect the LCD connector | 
| 
 | Hard disk drive | 
| 
 | LCD inverter ID | 
| 
 | LCD cable | 
| 
 | LCD Inverter | 
| 
 | LCD | 
| 
 | System board | 
| 
 | 
 | 
| No beep,  | Reconnect the LCD connectors. | 
| LCD is blank. But you can see POST on an | LCD inverter ID | 
| external CRT. | LCD cable | 
| 
 | |
| 
 | LCD inverter | 
| 
 | LCD | 
| 
 | System board | 
| 
 | 
 | 
| Chapter 4 | 95 |