Extron electronic PCM 240 Install the Electrical Box, Secure the PCM Base Plate to the Ceiling

Page 2

PCM 240 • Installation Guide (Continued)

f.Using these dimensions, mark and cut a hole (using a 2 inch hole saw) for the projector pipe in the removed ceiling tile (see figure 3).

g.If required, to prepare the ceiling tile for a power outlet, use the PCM plate to trace and cut out the 2-gang hole in the ceiling tile for a

UL approved RACO® junction box.

If this is not required, proceed to step 3.

Step 2 — Install the Electrical Box.

The following method is recommended for integrating a RACO electrical box (not supplied) on the PCM base plate. A RACO box (#8471), an MK box, or standard UL electrical boxes can be inserted. Mounting holes for Extron

3 inch deep, ¼ rack wide devices are also included. Install the RACO box on the PCM plate as follows:

a.Attach the box to the plate, using the smallest notches in opposite corners of the cut-out. Do not tighten the screws fully at this time.

b.On the room side of the tile, slide the plaster ring under the screws.

c.Fully tighten the screws

WARNING: Risk of Personal Injury. For safety, complete all wiring of the electrical boxes and accessories after the plate is installed and secure.

All electrical installation should be done by a qualified electrician.

Top Side

Underside

Figure 3. Mark and start cutting on underside. Finish on top side.

3" Deep, ¼ Rack

Device Mounting Holes

1-gang and 2-gang Electrical Box Cut-outs

Raco and MK Box Cut-out

Figure 4. RACO and MK Box

Installation Points.

Step 3 — Secure the PCM Base Plate to the Ceiling.

Tie wire installation

a.Replace the cut ceiling tile, checking the orientation.

b.Replace the PCM base plate over the ceiling tile and align the hole with the PCM adapter plate.

c.Attach the four turnbuckles to the mounting plate, one at each corner.

ATTENTION: Risk of Personal Injury and property damage.

DO NOT rest or lean on the mounting plate or suspended ceiling when attaching the turnbuckles and tie wire, or when drilling into the ceiling.

For safest installation, insert the turnbuckle from the outside so that it hooks inwards.

d.Mark and drill four holes, approximately 1¼ inch (32 mm) deep into the ceiling joists, using a 1/4 inch (6.4 mm) diameter drill bit. Do this at 10 degrees out from vertical. Drill a fifth hole centered above the PCM for the safety cable (see figure 5). Minimum suitable joist size should be

2 inches by 4 inches.

e.Install appropriate anchors or lag eye bolts for the structural ceiling into each drilled hole.

Attach turnbuckles to long sides.

T-bar

T-bar Securing

Screws

Attach ceiling

10 anchors and wire 10 degrees from vertical.

Mounting Plate

Pipe Adapter Plate

Lock Nuts

Figure 5. Attach Tie Wire and Safety Cable.

2

Image 2
Contents Mark the Frame and Cut the Ceiling Tile Pre-InstallationInstallation Install the Electrical Box Secure the PCM Base Plate to the CeilingFinal Installation Adjust the TurnbucklesSpecifications General
Related manuals
Manual 3 pages 38.69 Kb Manual 10 pages 11.64 Kb

PCM 240 specifications

The Extron Electronics PCM 240 is a powerful and versatile product designed for managing audio signals in various professional applications. This innovative audio processor is particularly well-suited for environments such as lecture halls, conference rooms, and corporate settings, where high-quality audio is paramount for effective communication.

One of the standout features of the PCM 240 is its advanced audio processing capabilities. The device includes a high-performance DSP (Digital Signal Processor), which ensures precise control over audio signals. With up to 24 simultaneous inputs and 12 outputs, the PCM 240 can handle complex audio routing, allowing seamless integration of multiple audio sources. It supports a variety of input and output formats, including analog, AES/EBU digital, and even Dante networked audio, making it a flexible solution for diverse audio requirements.

The PCM 240 incorporates Extron's renowned technology, such as the patented audio feedback suppression and dynamic range processing. These features enhance audio clarity and prevent feedback issues that can detract from the listening experience. The built-in equalization options offer users detailed control over sound shaping, ensuring optimal audio performance tailored to specific room acoustics.

Another innovative characteristic of the PCM 240 is its user-friendly interface. The device comes equipped with an intuitive web-based control platform that allows for easy access and monitoring from various devices. This enhances user experience, enabling quick adjustments to audio settings without the need for extensive technical knowledge. Additionally, the PCM 240 supports Extron’s Global Scripter, which enables custom control system programming, further increasing flexibility in audio management.

The build quality of the PCM 240 is also noteworthy. Designed for durability and reliability, the device is housed in a robust enclosure, making it suitable for continuous use in demanding environments. The PCM 240 also adheres to Extron’s standards for energy efficiency, contributing to lower operational costs and a smaller carbon footprint.

In summary, the Extron PCM 240 is a state-of-the-art audio processor that combines advanced processing technology, comprehensive connectivity options, and user-friendly controls. It is an ideal solution for any professional audio application, providing the tools necessary for optimal audio performance and control.